20 changes: 10 additions & 10 deletions src/dsmr/fields.h
Original file line number Diff line number Diff line change
Expand Up @@ -465,26 +465,26 @@ namespace dsmr
DEFINE_FIELD(current_sum, FixedValue, ObisId(1, 0, 90, 7, 0), FixedField, units::A, units::mA);

/*
* LUX and Lithuania
* LUX, Lithuania and Sweden
*/
/* TODO: by IEC 62056 unit's shoudl be kvar, safe to change? */
/* IEC 62056 define the unit of reactive power as kvar. Some meters e.g. L+G E360 uses mixed case kVar */
/* Instantaneous reactive power L1 (+Q) in W resolution */
DEFINE_FIELD(reactive_power_delivered_l1, FixedValue, ObisId(1, 0, 23, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_delivered_l1, FixedValue, ObisId(1, 0, 23, 7, 0), FixedField, units::kvar, units::kvar);
/* Instantaneous reactive power L2 (+Q) in W resolution */
DEFINE_FIELD(reactive_power_delivered_l2, FixedValue, ObisId(1, 0, 43, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_delivered_l2, FixedValue, ObisId(1, 0, 43, 7, 0), FixedField, units::kvar, units::kvar);
/* Instantaneous reactive power L3 (+Q) in W resolution */
DEFINE_FIELD(reactive_power_delivered_l3, FixedValue, ObisId(1, 0, 63, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_delivered_l3, FixedValue, ObisId(1, 0, 63, 7, 0), FixedField, units::kvar, units::kvar);

/*
* LUX and Lithuania
* LUX, Lithuania and Sweden
*/
/* TODO: by IEC 62056 unit's shoudl be kvar, safe to change? */
/* IEC 62056 define the unit of reactive power as kvar. Some meters e.g. L+G E360 uses mixed case kVar */
/* Instantaneous reactive power L1 (-Q) in W resolution */
DEFINE_FIELD(reactive_power_returned_l1, FixedValue, ObisId(1, 0, 24, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_returned_l1, FixedValue, ObisId(1, 0, 24, 7, 0), FixedField, units::kvar, units::kvar);
/* Instantaneous reactive power L2 (-Q) in W resolution */
DEFINE_FIELD(reactive_power_returned_l2, FixedValue, ObisId(1, 0, 44, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_returned_l2, FixedValue, ObisId(1, 0, 44, 7, 0), FixedField, units::kvar, units::kvar);
/* Instantaneous reactive power L3 (-Q) in W resolution */
DEFINE_FIELD(reactive_power_returned_l3, FixedValue, ObisId(1, 0, 64, 7, 0), FixedField, units::none, units::none);
DEFINE_FIELD(reactive_power_returned_l3, FixedValue, ObisId(1, 0, 64, 7, 0), FixedField, units::kvar, units::kvar);

/* Apparent instantaneous power (+S) in kVA resolution */
DEFINE_FIELD(apparent_delivery_power, FixedValue, ObisId(1, 0, 9, 7, 0), FixedField, units::kVA, units::VA);
Expand Down