Alpha firmware for the Creality K2 / K2 Combo (F021). Supervise prints and
keep the rollback path. Update from v0.3 with the Update button in Mainsail
or on the touchscreen (your printer-overrides.cfg is kept), or install with
the one-line installer in docs/INSTALL.md.
K2 without a CFS, and CFS hot-plug
- Printers without a CFS work. Like Creality's firmware, the printer
looks for the CFS at every start and, without one, feeds from the rear
spool holder. Unplugging or plugging in a CFS while the printer is idle is
picked up in under a minute, with no restart. - External spool card in Mainsail and page on the touchscreen, in place
of the CFS ones: set the filament, load, unload (cut at the knife) and
calibrate pressure advance. The external spool has its own filament record
(slot E), which OrcaSlicer sees as its first filament. - New
LOAD_FILAMENT/UNLOAD_FILAMENT(Mainsail Load/Unload buttons).
Files that ask for T1-T3 on a printer without a CFS stop with a message. - Fix for every CFS owner: v0.3 shipped our test printer's CFS id, which
is what gives the CFS its bus address back after a power-off. The driver
now finds any CFS itself with Creality's discover command, and starts a
CFS that is still in its loader after being plugged in. [k2_cfs] cfs_fitted: auto(default),TrueorFalsein
printer-overrides.cfgif you want to force it.
Calibration
PA_CAL_STATIC SLOT=x: pressure advance with the nozzle standing still
over the chute, from the nozzle strain gauge (Dmitry Butyugin's
pa_tester). Both the speeding-up and slowing-down steps fit now.- Flow tools in
tools/flow/: maximum-flow test from nozzle pressure, and a
flow-ratio pad generator. - Mainsail's slot dialog has Load, Unload and Calibrate PA buttons for CFS
slots too.
Ported from Jacob10383's K2 Plus firmware (credited in each file)
- Motor faults are decoded and acted on (a faulted controller used to look
like no answer), with newMOTOR_FAULTS,MOTOR_TEMPSand related checks. - PRTouch: fail-closed arming, re-probe of mesh taps that land on a blob,
optional multi-tap Z home and mesh, andPRTOUCH_SCRUB, the
strip-detecting nozzle scrub (opt-in). - CFS: shorter purge on a same-filament runout refill, BUSY retries,
plain-English status codes,CFS_RFID_READ, and optional clog detection.
Full list: CHANGELOG.md. Tested on our K2 (F021) running on