Skip to content

K2 OpenKlipper v0.4.18-alpha.1

Pre-release
Pre-release

Choose a tag to compare

@grant0013 grant0013 released this 03 Nov 02:30
· 54 commits to main since this release

K2 OpenKlipper v0.4.18-alpha.1

Alpha firmware for the Creality K2 / K2 Combo (F021) and the K2 Plus (F008).
Supervise prints and keep the rollback path. Update with the Update button
in Mainsail or on the touchscreen (your printer-overrides.cfg is kept), or
install with the one-line installer in docs/INSTALL.md.

Highlights

  • Flow calibration at print start: the printer measures where its
    hotend stops keeping up and caps that print to it (off by default, one
    line to turn on).
  • Fan rpm in Mainsail and on the touchscreen, with a health check at
    every print start and a measured minimum speed for the part fan.
  • 110 V printers get their bed power back: the mains voltage is checked
    once and the right power and PID set applied.
  • K2 Plus out of beta: no install gate, automatic belt tensioning, saved
    Z tilt.
  • Power-loss recovery, silent colour-change retries and per-slot CFS
    counts
    (from the 2 November part of this release).
  • A new boot animation, and Creality's kept for anyone who wants it back.

Printing

  • Max flow measured at the chute (hark_flow_cal): 8 mm^3/s upwards in 3 s
    steps on the strain gauge; the knee is where the pressure leaves the line
    by 4%, the cap is 3 mm^3/s under it, held with SET_MAX_FLOW for that
    print only. Turn on with [gcode_macro _FLOW_AUTO] variable_on_print_start: 1; FLOW_CAL_STATIC runs it by hand.
  • Extruder motor reads fixed (they were one request behind), plus
    MOTOR_VALUES, MOTOR_LOG_START/STOP and MOTOR_GET_PROBE.
  • Power-loss recovery (PLR_RESUME CONFIRM=1, touchscreen Discard/Resume),
    a failed colour change pauses instead of ending the print and RESUME
    retries it, loads retry silently, per-slot counts with a warning for a
    slot that keeps failing, Orca's own purge length for every change, CFS
    loads ~10 s faster, PETG purges with the part fan off, cutter calibration
    with the X/Y motors, a stuck nozzle-sensor pin shaken free.

Fans

  • tachometer_pin on the part, hotend and PTC fans: rpm everywhere.
    [fan_feedback] removed. Rpm is true at full speed only (the fans are
    powered through their PWM); 0 means stopped.
  • FAN_CHECK / FAN_HEALTH keep each fan's full-speed rpm and warn with
    !! when one slows 15% or stops; _FAN_AUTO runs it at every print
    start. FAN_MIN_CAL finds the lowest duty the part fan keeps turning at
    and M106 never asks for less.

Bed heater

  • hark_bed_power (K2): the mains test from Creality's firmware (30 C at
    half power, 0.35 C/s divide) runs once before the first print and picks
    the 110 V or 220 V power and PID set; voltage: 110|220 forces it;
    BED_POWER_CALIBRATE, BED_POWER_STATUS, BED_POWER_SET.

Touchscreen

  • Fans box: part fan rpm (or its usual), a Hotend fan line, colours for a
    slow or stopped fan.
  • Boot animation: the Hark Tech badge, "K2 OpenKlipper", harktech.co.uk.
    OKL_BOOTANIM=keep keeps Creality's; OKL_BOOTANIM=/folder installs your
    own from a logo (tools/bootanim/make_bootanim.py,
    docs/SCREEN-CUSTOMISE.md). Creality's set is backed up and uninstall.sh
    restores it.
  • Time zone picker, USB eject, chamber target and the other screen fixes
    from v0.4.15-v0.4.17 are included.

K2 Plus

  • Install without OKL_K2PLUS_BETA=1: tested on a real K2 Plus since 31
    October (no CFS; a CFS-equipped Plus is still untested).
  • BELT_TENSION_STATUS and BELT_TENSION CONFIRM=1 drive the automatic
    tensioners (stock's routine, 140 N). Not yet run on a real printer: step
    10 of the K2 Plus guide.
  • Z_TILT_APPLY_SAVED and _Z_TILT_START mode: "saved" skip the tilt probe
    at print start once a printer has proven stable.
  • Stock extruder PID, bed check 120 s, Z tilt at 300 mm/s (nur00's review).

Also

  • MAINTENANCE_STATUS / MAINTENANCE_DONE: hours, grams and cuts against
    Creality's maintenance thresholds, listed when a print ends.
  • FIRST_LAYER_PAUSE ENABLE=1, SILENT_MODE ENABLE=1, and an optional
    second extruder PID set above 280 C.
  • docs/PROJECT-STATUS.md: what is still only in Creality's firmware.

Upgrade notes

  • The first print after this update heats the bed 30 C at half power
    before its own heat-up, once, to check the mains voltage (K2 only). To
    skip it: [gcode_macro _BED_POWER_AUTO] variable_on_first_print: 0, or
    [hark_bed_power] voltage: 220 in printer-overrides.cfg.
  • Every print start now blasts the part fan for 3 s and reads the hotend
    fan at the chute (_FAN_AUTO); turn off with variable_on_print_start: 0 if you prefer.
  • The flow calibration is off until you turn it on (above); it adds about
    25 s and 70 mm of filament to a print start.
  • The boot animation changes at this update unless you install with
    OKL_BOOTANIM=keep.
  • [fan_feedback] in a printer-overrides.cfg of your own must go: its pins
    are the fans' tachometers now.

Full list in CHANGELOG.md.