Original file line number Diff line number Diff line change
Expand Up @@ -376,23 +376,23 @@ protected ExpertFilter buildExpertFilter(GlobalFilter globalFilter, EquipmentTyp
protected List<FieldType> getNominalVoltageFieldType(EquipmentType equipmentType) {
return switch (equipmentType) {
case LINE, TWO_WINDINGS_TRANSFORMER -> List.of(FieldType.NOMINAL_VOLTAGE_1, FieldType.NOMINAL_VOLTAGE_2);
case VOLTAGE_LEVEL -> List.of(FieldType.NOMINAL_VOLTAGE);
case VOLTAGE_LEVEL, GENERATOR -> List.of(FieldType.NOMINAL_VOLTAGE);
default -> List.of();
};
}

protected List<FieldType> getCountryCodeFieldType(EquipmentType equipmentType) {
return switch (equipmentType) {
case VOLTAGE_LEVEL, TWO_WINDINGS_TRANSFORMER -> List.of(FieldType.COUNTRY);
case VOLTAGE_LEVEL, TWO_WINDINGS_TRANSFORMER, GENERATOR -> List.of(FieldType.COUNTRY);
case LINE -> List.of(FieldType.COUNTRY_1, FieldType.COUNTRY_2);
default -> List.of();
};
}

protected List<FieldType> getSubstationPropertiesFieldTypes(EquipmentType equipmentType) {
return equipmentType == EquipmentType.LINE ?
List.of(FieldType.SUBSTATION_PROPERTIES_1, FieldType.SUBSTATION_PROPERTIES_2) :
List.of(FieldType.SUBSTATION_PROPERTIES);
List.of(FieldType.SUBSTATION_PROPERTIES_1, FieldType.SUBSTATION_PROPERTIES_2) :
List.of(FieldType.SUBSTATION_PROPERTIES);
}
}

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -345,14 +345,16 @@ private static Stream<Arguments> fieldTypeData() {
// Nominal voltage
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.LINE, List.of(FieldType.NOMINAL_VOLTAGE_1, FieldType.NOMINAL_VOLTAGE_2)),
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.TWO_WINDINGS_TRANSFORMER, List.of(FieldType.NOMINAL_VOLTAGE_1, FieldType.NOMINAL_VOLTAGE_2)),
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.GENERATOR, List.of(FieldType.NOMINAL_VOLTAGE)),
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.VOLTAGE_LEVEL, List.of(FieldType.NOMINAL_VOLTAGE)),
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.GENERATOR, Collections.emptyList()),
Arguments.of(GlobalFilter.Fields.nominalV, EquipmentType.BATTERY, Collections.emptyList()),

// Country code
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.GENERATOR, List.of(FieldType.COUNTRY)),
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.VOLTAGE_LEVEL, List.of(FieldType.COUNTRY)),
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.TWO_WINDINGS_TRANSFORMER, List.of(FieldType.COUNTRY)),
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.LINE, List.of(FieldType.COUNTRY_1, FieldType.COUNTRY_2)),
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.GENERATOR, Collections.emptyList()),
Arguments.of(GlobalFilter.Fields.countryCode, EquipmentType.BATTERY, Collections.emptyList()),

// Substation properties
Arguments.of(GlobalFilter.Fields.substationProperty, EquipmentType.LINE, List.of(FieldType.SUBSTATION_PROPERTIES_1, FieldType.SUBSTATION_PROPERTIES_2)),
Expand Down