Repository navigation
How to Acquire Your Data Suitable for FusionX
FusionX works best when the cell boundary and the nuclei both come through clearly. This page lists the labels, sample preparation, and imaging settings that worked for us. Treat them as a starting point, and test them on your own cells and microscope.
-
CellMask stains, DiI, DiO, DiD, wheat germ agglutinin conjugates, and the fixable CellBrite Fix and MemBrite Fix stains all work well. CellX segments the boundary, not a specific fluorophore.
-
Image within about an hour of staining. These dyes internalise over time, and the punctate cytoplasmic signal that follows blurs the boundary.
-
For live imaging over longer periods, use a genetically encoded marker such as mTmG, or a fluorescent protein targeted to the membrane through a CAAX, Lck, or GAP43 motif. These markers do not internalise, so they hold the boundary for the whole experiment.
-
Hoechst 33342, DAPI, Hoechst 33258, SPY-DNA, SiR-DNA, DRAQ5, the SYTO series, and the NucSpot Live dyes all work. A histone fusion such as H2B-FP serves the same purpose in stable lines.
-
Keep the two labels in channels that are well separated. Signal that bleeds through from the membrane channel distorts the nuclear masks that generate the prompts.
-
Fixed and live cells both work.
-
Keep fixed samples in PBS with calcium and magnesium (PBS++) and image them directly. Mounting media are often incompatible with membrane dyes and degrade the boundary signal.
-
Use confocal imaging. Rejecting light that is out of focus sharpens the membrane boundary.
-
Acquire large stitched montages rather than a few single fields. Syncytia spread unevenly across a culture, and sparse sampling misrepresents the fusion index.
-
Run autofocus at every field, on the nuclei channel. Nuclei give a compact, uniform reference, whereas the membrane signal spreads over the cell and focuses poorly.
-
FusionX tolerates dense cultures.
-
If the culture becomes so dense that cells grow on top of one another, expect some bias. A confocal cannot capture the cells that sit beneath others, so it misses them and undercounts the fusion index.
-
Test a few fields under different conditions first. Optimal settings vary between cell types and microscopes.
These examples come from our own imaging, and they show conditions where FusionX fails. They are not an exhaustive list, and you may run into other cases, but they are the ones we saw most often.

In box 1 the cell boundary is unclear. In box 2 the dye has moved inside the cells. In box 3 the nuclei are out of focus. These problems come from very high cell density together with dye that has internalised.

In box 1 the nuclei have started to break down. Box 2 shows an ideal labelled cell boundary for comparison. This happens when you image too late, so image earlier to avoid it.

In box 1 the nuclei themselves have fused. We saw this often when we imaged at a later time point.
Go back to Home
