Skip to content

v0.6.1 — corrected member checks and snow loads

Choose a tag to compare

@unbalancedparentheses unbalancedparentheses released this 15 Nov 15:25
· 636 commits to main since this release
v0.6.1
213f33e

Stabileo 0.6.1: corrected member checks and snow loads

English · Español · Português · Deutsch · Français · Türkçe

Released 2026-11-15. These notes cover changes since v0.6.0. The full record is in CHANGELOG.md.

Your results may change: re-run affected projects

Re-run affected concrete and steel design checks. For generated snow, regenerate the loads first, then re-run affected load cases, combinations, envelopes and derived design checks. Re-solving previously saved loads alone does not repair them. Compare demands, capacities, reinforcement, utilization, governing combinations and certificates with results already used. Review delivered calculations and sizing based on them. A refusal, an unavailable quantity or unchecked reinforcement supplies no passing answer and is not zero demand.

Safety advisories

The following five High-severity advisories are fixed in 0.6.1. Follow each advisory for its affected inputs and user action, even if earlier results passed or were certified.

Advisory Severity What changed and what to do
SA-2026-064 High Steel Cb could come from another combination or an unlocated short unbraced span (#1316, #2088). Re-run CIRSOC 301 steel checks and review flexural capacity, interaction utilization and governing combinations.
SA-2026-065 High Roof-step drift could be omitted on a pitched receiving roof (#2082). Regenerate CIRSOC 104 snow loads and re-run affected analyses and design checks.
SA-2026-066 High Concrete Cm could receive end-moment credit with transverse load between supports (#2089). Re-check slender concrete columns and walls, magnified moments and reinforcement.
SA-2026-067 High Plan rotation could change generated snow loads (#2093). Regenerate loads using the actual roof geometry, then re-run analyses and checks; rotating an old model back is not a repair.
SA-2026-068 High Torsion could pass with inadequate designed stirrups (#2141). Re-run concrete design checks and review actual transverse capacity, stirrup spacing and torsion failures. Unchecked longitudinal provision is not a passing cage.

Every results-change notice since v0.6.0

The registry at v0.6.0 ends at results version 78; this release reaches 80. The table lists all 24 new notices. Several notices share a version. Each link records scope and evidence. Re-run every applicable check; for snow notices, regenerate loads before re-solving.

Results version Result that changes
79 Snow drift coverage follows continuous roof edges
79 Snow overrides preserve unbalanced sides and section runs
79 Flat snow frames follow connected roof runs
79 Snow loads respect local positions and drift boundaries
79 Snow factors follow each roof orientation
79 Snow cases cover every ridge orientation
79 Snow fetch follows continuous roofs and selected geometry
79 Snow loads retain their magnitude under plan rotation
79 Roof-step drift uses the receiving roof plane
79 Snow loads follow each connected roof surface
79 Snow tributaries use interior roof surfaces
80 Member checks require every active combination
80 Complete station data is required for member checks
80 Concurrent checks retain governing demands
80 Design uses selected bars and known span loading
80 Interaction checks use concurrent station forces
80 Concrete checks retain secondary slenderness
80 Concurrent cases retain all required torsion reinforcement
80 Fixed reinforcement retains the practical maximum check
80 Design demands respect behaviour and flange spans
80 Torsion checks every returned stirrup cage
80 Shared beams retain their axes; torsion provision must be stated
80 Steel interaction Cb uses its own combination diagram
80 Steel stations use physical lengths and retain shear demands

Other changes

Concrete and steel checks retain forces from the same combination and station. Incomplete combination or station data now refuses instead of borrowing an endpoint result. Required and provided reinforcement states remain separate, and missing longitudinal torsion provision is reported explicitly. Repeated identical design work is reused while every demand remains checked. Legacy-project comparisons now retain the released material and section defaults; saved projects and migrations are unchanged.

Known limitations

  • Known wrong results remain open: #2096, #2142, #2143 and #2144. This release does not fix them. Consult their affected scope and independently verify affected results before use.
  • SA-2026-056 remains unfixed: independently verify dynamic demands for constrained mixed frame-and-shell models that change materially after renumbering, rotation or unit conversion. No conservative correction factor is established.
  • 2D plastic collapse remains refused pending #758, as described in SA-2026-044. A certified 3D lower bound does not certify the raw hinge history.
  • Time history does not provide total dynamic support demands. Use an independent analysis including inertia, damping and support loading. Unsupported cable analyses and nonzero prescribed support motion in cable/time-history workflows refuse explicitly.
  • Spatial arc-length and displacement-control solvers are not added. Existing warnings and restrictions remain applicable.