Repository navigation
v1.1.40
FanControl.LianLi v1.1.40, released 2026-11-17
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.40.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.40.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.40.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
ci: release only when what ships changes, and skip builds for docs
With the previous commit, a push to main now cuts a release only when it changes the plugin's source, the build settings, the SDK, the license or the install notes, and the release notes list only those commits, so a docs, test or CI change no longer publishes a new version. The install notes in each zip are written from .github/install-template.txt and a notes file per build, and a placeholder left in them fails the release.
Build runs only when something compiled or tested changes. The format check and the package scan run on Linux, and the shellcheck job, which had no scripts to check, is gone.
fix: name the ARGB and Lighting DLLs so FanControl's Install plugin button accepts them
FanControl's Install plugin button only takes a DLL named FanControl.Name.dll, with exactly three parts. The ARGB and Lighting builds were named FanControl.LianLi.Argb.dll and FanControl.LianLi.Lighting.dll, so the button turned them down with "Could not find plugin dll in zip archive" or "Wrong plugin format", and the only way in was to copy the file into the Plugins folder by hand. They are now FanControl.LianLi-Argb.dll and FanControl.LianLi-Lighting.dll and install with the button like the standard build. The plugin names FanControl shows are the same, so your curves stay bound.
Anyone who copied an older ARGB or Lighting DLL in by hand would now end up with two copies loaded, both driving the same fans. When FanControl has loaded more than one copy of the plugin, the newest one now drives and moves the other copy's file out of the way, and the leftover file is deleted the next time FanControl starts. Until the old copy is gone, the new one waits so the two never fight over the fans. If Windows will not let the plugin move the file, the log says which file to delete.
fix: read TL and Galahad RPM only from the reply to the current poll
A TL hub's RPM could fall behind and stay behind. Windows gives every program that has the hub open its own copy of every reply the hub sends, so when another program also asks the hub for its RPM, its replies pile up in front of the plugin's and the plugin reads an older one each second. The same happened if 32 or more other replies were waiting in front of the answer. A second program on the same hub is what the code allows for and what fits the report, but it has not been confirmed.
Before every write to a TL hub or Galahad cooler, the plugin now throws away any replies it has not read, so a poll only sees what arrives after it asks. It takes a reply only if it is the answer to the RPM request, the same check L-Connect makes. A TL hub that does not answer is asked a second time, as L-Connect does. A poll gives up after 450 ms on a TL hub and after a second on a Galahad, the most L-Connect itself waits, so a flood of other replies cannot hold up fan control.
When a hub or cooler does not answer, the last RPM readings are kept, and a TL fan that answered after the others is still added on time. The log says so once when it stops answering and once when it answers again. A Galahad no longer shows another reply as a fan or pump speed.
Running another program against the same hub is still not supported: both send speeds and the fans follow whichever wrote last.
feat: pair every control with its fan speed in FanControl
FanControl V245 lets a plugin say which fan speed belongs to a control, so the control shows its RPM and calibration, RPM curves and fan identification work without pairing anything by hand. Every control now names its own reading: a hub channel, a TL fan and a pump name their own RPM, and a wireless group, a cooler's fans or a FLEX chain name the first fan, the one L-Connect shows for the group. A pairing you made yourself is kept. FanControl puts the plugin's pairing back if you click Unpair, so Unpair no longer sticks; pair the control with another sensor instead if you want a different one.
A fan the plugin has not measured, because its hub or cooler has not answered yet, its wireless device is not being heard or its controller has not been reopened yet (after sleep, say), used to read 0 RPM. FanControl takes 0 from a paired fan as a fan that failed to start and, with a Start % set, raises its command until it reads again, so the fans could come back at full speed. Such a fan now shows - instead of a reading until it is measured again, as the coolant temperature already did. A fan that is heard and stopped still reads 0.
This needs FanControl V245 or newer, up from V243. On an older FanControl the plugin cannot be loaded and FanControl loses its other sensors too, so update FanControl first. No control or sensor id has changed, so curves stay bound.
Full changelog: v1.1.39...v1.1.40