Repository navigation
Releases
v1.1.44
FanControl.LianLi v1.1.44, released 2026-11-22
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.44.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.44.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.44.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
fix: show no speed or temperature for a wired controller that has stopped answering
A wired hub, TL hub, Galahad II, FLEX receiver or HydroShift pump that dropped off USB kept showing the last speeds and coolant temperature it reported for as long as it was gone, so a curve following the pump's coolant temperature went on following a frozen value and a dead hub looked healthy. After 30 failed polls in a row, about half a minute, the same count after which a wireless device that is not heard reads nothing, its readings are now forgotten and FanControl shows none until it answers again. FanControl stops driving a fan whose curve has no temperature, so the hub falls back to its own control. A shorter run of failures, such as the reopen after a wake, keeps the last readings.
fix: retry a controller that has gone at least every 30 seconds, timed on the clock
A faulted handle was reopened, and a controller a scan could not reach rebuilt, on a schedule that counted attempts: a first gap of 10 and a ceiling of 640. A wired hub offers about one a second, so one that had been gone a few minutes was tried only every five to eleven minutes, and one plugged back in could stay uncontrolled that long. A wireless pair offers several a second, so the same schedule ran faster for it. The schedule is now timed in milliseconds on the monotonic clock the call gate already uses: the first try at once, the next after five seconds as before, doubling to at most 30 seconds between tries. A controller plugged back in is driven again within about half a minute.
Full changelog: v1.1.43...v1.1.44
Built from commit 9259cd372a765d8d0a87df67dae2251e47cb53ae.
v1.1.43
FanControl.LianLi v1.1.43, released 2026-11-22
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.43.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.43.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.43.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
perf: wake the controllers only when a whole-percent duty changes
FanControl's curves pass fractional values, and a control woke every controller whenever the value changed at all, so 43.2 to 43.6 had each one poll its fan speeds early although the 43% sent to the device stayed the same. On a wired hub that is a primer, a 20 ms wait and a report read per controller for nothing. A control now wakes them only when the whole percent it sends changes. What is sent and when is unchanged.
perf: build each transfer's name and delegate once instead of on every transfer
Every HID transfer formatted its operation name, joined it to the device path for the timeout's log line and made a fresh delegate for the native call, a few times a second per controller, for text that is almost never logged. They are now built once per transport and reused, cutting what one wired hub's tick allocates from about 2.8 KB to 1.9 KB. Every name and log line is unchanged.
Full changelog: v1.1.42...v1.1.43
Built from commit 170a070aca8055d76b9ee79fc527722923af89da.
v1.1.42
FanControl.LianLi v1.1.42, released 2026-11-22
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.42.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.42.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.42.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
fix: reuse the thread each device call runs on instead of starting a new one
Every read and write to a controller ran on a thread started for it alone, a few times a second. Each finished thread left about three Windows handles in FanControl until it next collected garbage, and FanControl allocates so little that it can go a long time without collecting: with three SL-Infinity hubs FanControl.Service's handle count climbed by about 20 a second, past 31,000 after 25 minutes. A call now runs on a thread kept for the next call once it returns in time, so the count stays flat at around 630. A thread whose call is given up on is still never used again, so cancelling its call by thread can never reach a later one.
fix: log a fan's first speed only, not every change of it
Every change of a fan's speed was logged, and a curve moves it hundreds of times a day: about 950 lines a day with three SL-Infinity hubs, by far most of what the plugin logged in normal running. Other FanControl plugins log nothing while running normally. Each fan now logs the first speed it is given after start or a reconnect, which still shows the plugin is driving it, and nothing for later changes. A wireless fan still logs being released.
fix: write the plugin's log once, to plugin.log, instead of to FanControl's log as well
Every line went to both the plugin's own plugin.log and FanControl's service log, so each was written to disk twice, and before v1.1.41 the plugin made up almost all of FanControl's log. Other plugins log only to FanControl's log, but plugin.log keeps to two files of 4 MB, times lines to the millisecond, and is what the docs and issue replies already ask for, so it is the copy kept. FanControl's log now gets one line each time the plugin starts, with the full path of the plugin.log in use, so anyone reading it can find the plugin's log.
Full changelog: v1.1.41...v1.1.42
Built from commit 779b5d6edb4c943a6a47cdcde659e958fee1729b.
v1.1.41
FanControl.LianLi v1.1.41, released 2026-11-22
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.41.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.41.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.41.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
fix: stop logging the same line over and over while nothing changes
A Uni hub, TL hub or Galahad II channel logged a Set line every time its speed was re-sent to keep the controller from falling back to full speed, so six TL fans wrote about 35,000 identical lines a day to the plugin's own log and to FanControl's service_log.txt (Rem0o/FanControl.Releases#4279). Only a change of speed is logged now, as the wireless, FLEX and HydroShift controllers already did. The re-send itself is unchanged.
A controller that stopped answering (unplugged, or wedged after sleep) logged a poll err line every second until it came back, and a reconnect failure on every retry. Each different failure is now logged once when it first happens, and the recovery once with how many ticks or attempts it took.
Full changelog: v1.1.40...v1.1.41
Built from commit 0453984361b7ff245255fb745730bc6536d2617c.
v1.1.40
FanControl.LianLi v1.1.40, released 2026-11-17
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.
Important
This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.40.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.40.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.40.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
ci: release only when what ships changes, and skip builds for docs
With the previous commit, a push to main now cuts a release only when it changes the plugin's source, the build settings, the SDK, the license or the install notes, and the release notes list only those commits, so a docs, test or CI change no longer publishes a new version. The install notes in each zip are written from .github/install-template.txt and a notes file per build, and a placeholder left in them fails the release.
Build runs only when something compiled or tested changes. The format check and the package scan run on Linux, and the shellcheck job, which had no scripts to check, is gone.
fix: name the ARGB and Lighting DLLs so FanControl's Install plugin button accepts them
FanControl's Install plugin button only takes a DLL named FanControl.Name.dll, with exactly three parts. The ARGB and Lighting builds were named FanControl.LianLi.Argb.dll and FanControl.LianLi.Lighting.dll, so the button turned them down with "Could not find plugin dll in zip archive" or "Wrong plugin format", and the only way in was to copy the file into the Plugins folder by hand. They are now FanControl.LianLi-Argb.dll and FanControl.LianLi-Lighting.dll and install with the button like the standard build. The plugin names FanControl shows are the same, so your curves stay bound.
Anyone who copied an older ARGB or Lighting DLL in by hand would now end up with two copies loaded, both driving the same fans. When FanControl has loaded more than one copy of the plugin, the newest one now drives and moves the other copy's file out of the way, and the leftover file is deleted the next time FanControl starts. Until the old copy is gone, the new one waits so the two never fight over the fans. If Windows will not let the plugin move the file, the log says which file to delete.
fix: read TL and Galahad RPM only from the reply to the current poll
A TL hub's RPM could fall behind and stay behind. Windows gives every program that has the hub open its own copy of every reply the hub sends, so when another program also asks the hub for its RPM, its replies pile up in front of the plugin's and the plugin reads an older one each second. The same happened if 32 or more other replies were waiting in front of the answer. A second program on the same hub is what the code allows for and what fits the report, but it has not been confirmed.
Before every write to a TL hub or Galahad cooler, the plugin now throws away any replies it has not read, so a poll only sees what arrives after it asks. It takes a reply only if it is the answer to the RPM request, the same check L-Connect makes. A TL hub that does not answer is asked a second time, as L-Connect does. A poll gives up after 450 ms on a TL hub and after a second on a Galahad, the most L-Connect itself waits, so a flood of other replies cannot hold up fan control.
When a hub or cooler does not answer, the last RPM readings are kept, and a TL fan that answered after the others is still added on time. The log says so once when it stops answering and once when it answers again. A Galahad no longer shows another reply as a fan or pump speed.
Running another program against the same hub is still not supported: both send speeds and the fans follow whichever wrote last.
feat: pair every control with its fan speed in FanControl
FanControl V245 lets a plugin say which fan speed belongs to a control, so the control shows its RPM and calibration, RPM curves and fan identification work without pairing anything by hand. Every control now names its own reading: a hub channel, a TL fan and a pump name their own RPM, and a wireless group, a cooler's fans or a FLEX chain name the first fan, the one L-Connect shows for the group. A pairing you made yourself is kept. FanControl puts the plugin's pairing back if you click Unpair, so Unpair no longer sticks; pair the control with another sensor instead if you want a different one.
A fan the plugin has not measured, because its hub or cooler has not answered yet, its wireless device is not being heard or its controller has not been reopened yet (after sleep, say), used to read 0 RPM. FanControl takes 0 from a paired fan as a fan that failed to start and, with a Start % set, raises its command until it reads again, so the fans could come back at full speed. Such a fan now shows - instead of a reading until it is measured again, as the coolant temperature already did. A fan that is heard and stopped still reads 0.
This needs FanControl V245 or newer, up from V243. On an older FanControl the plugin cannot be loaded and FanControl loses its other sensors too, so update FanControl first. No control or sensor id has changed, so curves stay bound.
Full changelog: v1.1.39...v1.1.40
Built from commit 83b0f10d0e8a130f3b2ebc1d5373a51593d03b08.
v1.1.39
FanControl.LianLi v1.1.39, released 2026-11-07
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. It needs FanControl V243 or newer, and the README lists the supported devices.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.39.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.39.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.39.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
Bump the nuget-minor-patch group with 1 update (#38)
build(deps): bump actions/setup-node from 7.0.0 to 7.1.0 in the actions-minor-patch group (#39)
Bump the nuget-minor-patch group with 2 updates (#40)
Bump the nuget-minor-patch group with 1 update (#41)
build(deps): bump actions/setup-dotnet from 6.0.0 to 6.1.0 in the actions-minor-patch group (#43)
docs: document the TL hub and why each TL fan is its own control
The TL hub talks to every fan in a daisy chain on its own and has no command that sets a whole port, so the plugin gives each fan its own control and RPM reading. L-Connect groups a port's fans in its own software, three to a group by default, and sends each fan in a group the same speed. To run a port as one in FanControl, pick the same curve on each fan's control or give the others a Sync curve.
docs/protocol.md gains a section on the TL hub's handshake, set-speed and motherboard sync commands, checked against L-Connect 3 (2.1.29).
Full changelog: v1.1.38...v1.1.39
Built from commit 996ca0914970b277c6e9c392f326c76591e036e8.
v1.1.38
FanControl.LianLi v1.1.38, released 2026-10-01
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. It needs FanControl V243 or newer, and the README lists the supported devices.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.38.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.38.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.38.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
test: accept either refresh reason when the radio takes a FLEX chain during Load
The test that has the radio take a FLEX chain while Load is registering waits only for the controller memory to change, so on a slow machine the radio's claim can finish after Load has published and ask for the refresh itself, with its own reason, before Load's check asks with the other. Both are right: the control is registered once and a refresh is asked for. The test failed on the Windows CI runner this way and now accepts either reason.
Covered by the same suite at 100% line, branch and method coverage in all three builds.
Full changelog: v1.1.37...v1.1.38
Built from commit 354d7839c93638212e8b3de8664a5c46187af7ee.
v1.1.37
FanControl.LianLi v1.1.37, released 2026-10-01
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. It needs FanControl V243 or newer, and the README lists the supported devices.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.37.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.37.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.37.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
docs: move the agent guide to AGENTS.md so Codex reads it too
The guide for coding agents lived in CLAUDE.md, which only Claude Code reads. It is now AGENTS.md, which Codex and other agents read, and CLAUDE.md imports it, so both see the same text. The rules stay in .claude/rules, which Claude Code loads by itself, and AGENTS.md now lists them and tells any other agent to read them before changing code.
docs: write the comments and docs in plain English
The comments, docs and agent rules had picked up a house style of their own: phrases like rather than, nobody, afresh, for good, the one thing that, only ever and byte for byte, and words like seam, surface, cadence, deliberately and exactly used as figures of speech or for emphasis. They now say the concrete thing instead, with every fact and every reason kept. Three log lines change wording (dropped for good is now dropped and not added again, is owed its screen switch is now will be sent its screen switch, plan it afresh is now plan it again), none of them a line the docs tell people to look for, and seven test names follow the same wording. The space-aligned folder lists in CONTRIBUTING.md and the architecture rule are now bullet lists.
No behaviour change. Covered by the same suite at 100% line, branch and method coverage in all three builds.
Full changelog: v1.1.36...v1.1.37
Built from commit 99f21b41c781f09b01d2f375d833c30ea4e81a5a.
v1.1.36
FanControl.LianLi v1.1.36, released 2026-10-01
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. It needs FanControl V243 or newer, and the README lists the supported devices.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.36.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.36.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.36.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
docs: write the release notes' download section the way the README does
The download section of the release notes read as a list of facts about the zips rather than telling a reader which one to pick. It now says which download fits how you control your lighting, with the Lighting build first, gives the three install steps, and links to the L-Connect steps and troubleshooting.
docs: fit the README's table of builds on one line per build
In the README's table of builds the icon and the build's name broke onto separate lines, and every description wrapped onto a second line. A non-breaking space now holds each icon to its name, and each description is cut down to who the build is for.
Full changelog: v1.1.35...v1.1.36
Built from commit cf2052e8c7acd9cedf833b7002a0fd875f917b39.
v1.1.35
FanControl.LianLi v1.1.35, released 2026-10-01
A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. It needs FanControl V243 or newer, and the README lists the supported devices.
Download and install
Download one of these:
- 🎨
FanControl.LianLi-Lighting-v1.1.35.zipif you set up your lighting in L-Connect. Most people want this one. - 🌈
FanControl.LianLi-Argb-v1.1.35.zipif your motherboard's RGB software controls your fan lighting. - 🌀
FanControl.LianLi-v1.1.35.zipif OpenRGB, SignalRGB or another tool controls your lighting.
- Extract the
.dllfrom the zip. - Right-click the
.dll, choose Properties, tick Unblock and click OK. - In FanControl, open the menu, click Install plugin and pick the
.dll.
If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.
What's changed
test: keep the bounded-call tests deterministic under load
The bounded-call tests drove the real bound with a 50 ms deadline and assumed the call had started by the time the caller gave up. BoundedDeviceCall starts a throwaway thread, and when that thread has not published its handle before the caller's wait expires it never runs the call at all, by design. On a loaded machine (a slow CI runner, a second test run alongside) a scenario about a call that was under way when the caller gave up could instead get a thread that never ran it, and then hang on an event nobody would set, fail after five seconds waiting for a report that could not come, or pass without proving anything.
Each of those scenarios now runs through one shared helper, AbandonedCallScenario, which repeats the scenario until the call was under way, up to twenty attempts. Every scenario sets a running event first thing in the call, waits with a bound for the call's return before deciding, so no event is disposed under a thread still using it, and releases the call on every path. The four tests whose timeout callback needs the call under way wait for the thread's decision either way, since a thread that is not going to run the call never sets the running event. The gate test takes each attempt over its own gate and log, the Windows-only pipe read test repeats until the read was blocked, and the builder test's deadline is given room for the fast build to be scheduled and finish on a loaded machine. No wait in the changed tests is unbounded, and every assertion about behaviour is kept for its own case.
Covered by the same suite at 100% line, branch and method coverage in all three builds.
fix: replay setup only once the device is back, and keep a refused look owed
After a controller was re-enumerated the transport moved its generation on the reopen and the controller replayed its setup on the tick after, and a look the device then refused, or that was cut short by the device going away again, was swallowed by the Lighting build's guarded apply and counted as replayed all the same. A Galahad II could come back from a re-enumeration without its look, and an SL-Infinity could whenever the reopen landed on its manual-mode write.
The transport now moves its generation the moment the handle is lost, before the next transfer reopens the device inside its own call, and reports its fault latch (IsFaulted) beside it, so a controller sees the loss before anything reaches the reopened device and knows when the device is actually back. Every controller that sets its device up (the Uni families, the TL hub, the Galahad II and the wireless pair through both dongles) replays nothing while the handle is still faulted: the device is off the bus, and its own transfers are what reopen it on the backoff. On the first tick after the generation has moved and the handle is open again it replays its setup in the order Initialize used and re-sends every duty, as before.
The registered replay now reports whether it was done, and the plugin's lighting apply reports false when its writes failed. A new Devices type, ReconnectReplay, owns the debt: the controller owes the look from the moment it sets the reopened device up, and only a replay that reports itself done clears it. One that fails stays owed on its own, without holding up fan control, and is tried again on the keepalive cadence, so a device that refuses its look for good costs a log line every fifteen seconds rather than every tick, and a device that comes back again has it owed afresh and tried at once.
Covered by unit tests at 100% line, branch and method coverage in all three builds, with the reconnect of every wired family driven over the real HID transport on the scripted native API, the fault, the backoff and the failed reopens included, whichever transfer the fault lands on and however many reopens fail before one succeeds. Verified on hardware with three SL-Infinity controllers on FanControl V269 and the Lighting build: all three found on their old paths with every curve still bound and the saved look applied, and after a pnputil disable and enable of all three, each reopened, had its setup and look replayed, and drove its curves again.
feat: drive the HydroShift II OLED Curve pump and read its liquid temperature
The HydroShift II OLED Curve's pump did not appear, because it is not on a HID controller: it rides on the cooler's lighting MCU (0x0416:0x8051), a WinUSB device that L-Connect 2.1.29 drives through its lcd207 SDK.
The plugin now finds that MCU with the WinUSB locator the wireless dongles use, opens it with the same transport and drives it as L-Connect does: eight-byte commands, each answered by one packet that is read after every write so a reply is never left in the pipe; the pump set by an output value derived from the target rpm through L-Connect's 22-point table with its rounding; the reported rpm corrected by L-Connect's per-band offsets; the speed re-sent every two seconds, the cadence of L-Connect's own pump timer; and the temperature and tachometer polled every tick. FanControl's 0 to 100% spans 1600 to 2400 rpm, the range every ordinary L-Connect pump mode drives, and the Turbo ceiling behind L-Connect's warning dialog is never asked for. The pump is taken off the motherboard's PWM header once at build, again after a reconnect, and once whenever its status reply says it has gone back to the header. The cooler registers a pump control, its rpm and the coolant temperature, is remembered and stood in for like the other controllers, and its screen, screen motor and lighting are left alone, since that lighting is a stream of frames L-Connect renders on the PC with no saved look to replay.
Each kind of WinUSB device is now opened under its own pipe policy (WinUsbPipePolicy): the pump MCU gets the 200 ms write and read timeouts L-Connect's SDK gives it and is read one packet at a time, where the dongles keep their timing and a reply read to its end. A set-pump or sync command the MCU does not answer is logged once and fails nothing, since L-Connect discards those replies: both transports now throw DeviceReplyMissingException, an IOException, for a read that got nothing within the pipe timeout, and the pump controller catches that one type. A status or tachometer reply that echoes another command is ignored rather than read as a temperature.
Covered by unit tests at 100% line, branch and method coverage in all three builds, with byte-level tests for every command, the output-value table and the rpm correction, and the reconnect driven over the real WinUSB transport on the scripted native API. The cooler is built from the decompile and has not been confirmed on that hardware. Checked on hardware with three SL-Infinity controllers on FanControl V269, which are found and driven as before.
feat: follow L-Connect 2.1.29's saved lighting on every wired family
A controller set to follow the motherboard in L-Connect was painted over with its saved look, because L-Connect 2.1.29 keeps its "sync to motherboard" switch per controller, saved beside the look as a MotherboardARGBSync setting, where 2.1.11 had one global setting the plugin never read. The Galahad II Vision's and the HydroShift LCD's saved looks, which the README already listed, were logged as an unsupported family and skipped, and a saved merge effect was replayed over the stale per-port looks rather than the way L-Connect shows it.
In the Lighting build a controller with the switch on is now handed to the motherboard the way L-Connect hands it over: a Uni controller gets its fan quantity and its ARGB-sync register, as L-Connect's own start and resume send them, a Strimer Plus its sync register and port enable, a Galahad II Trinity its look with the motherboard as the signal source and L-Connect's default for a light that was never saved, and a TL hub nothing, since L-Connect writes it none. A user on an older L-Connect has no such file and sees no change. A saved merge effect is shown the way L-Connect shows it on every Uni family: the SL-Infinity's default look and frame, then ports 7 to 1 blanked and port 0 last with no frame latch; the SL's StartMerge report and port 0 again; the AL's merge command and port 0; the SL v2's port 0 alone; and the AL v2's port 0 then ports 1 to 7 blanked. The SL-Infinity, SL v2 and AL v2 also take the merge-order report after the look and its frame, with the saved MergeOrder when there is a valid one, on every start and reconnect, where L-Connect's resume writes the default order. Every saved pump scope of a Trinity is replayed, and the SL-Infinity's default fan quantity, used when none was saved, is 3 per group, L-Connect's own default.
The Galahad II Vision and the HydroShift LCD now get their saved fan light through the Trinity's 0x85 command (the Vision saves its colours as Color1...