Skip to content

v1.1.44

Latest

Choose a tag to compare

@github-actions github-actions released this 22 Nov 08:26
9259cd3

FanControl.LianLi v1.1.44, released 2026-11-22

A FanControl plugin for Lian Li fans, AIO coolers and STRIMER cables. The README lists the supported devices.

Important

This plugin needs FanControl V245 or newer. Update FanControl from getfancontrol.com before you install or update it: on V244 or older the plugin can't load and FanControl shows none of its sensors, not even your motherboard and GPU ones.

Download and install

Download one of these:

  • 🎨 FanControl.LianLi-Lighting-v1.1.44.zip if you set up your lighting in L-Connect. Most people want this one.
  • 🌈 FanControl.LianLi-Argb-v1.1.44.zip if your motherboard's RGB software controls your fan lighting.
  • 🌀 FanControl.LianLi-v1.1.44.zip if OpenRGB, SignalRGB or another tool controls your lighting.
  1. Extract the .dll from the zip.
  2. Right-click the .dll, choose Properties, tick Unblock and click OK.
  3. In FanControl, open the menu, click Install plugin and pick the .dll.

If you copied an older ARGB or Lighting .dll into FanControl's Plugins folder by hand, you don't need to remove it. The plugin takes it out of the folder itself and takes over at FanControl's next refresh, or straight away if you restart FanControl. If you copied the Standard FanControl.LianLi.dll into the Plugins folder itself by hand, close FanControl and delete that copy before installing.

If you use L-Connect, switch it off first. If something isn't working, see troubleshooting.

What's changed

fix: show no speed or temperature for a wired controller that has stopped answering

A wired hub, TL hub, Galahad II, FLEX receiver or HydroShift pump that dropped off USB kept showing the last speeds and coolant temperature it reported for as long as it was gone, so a curve following the pump's coolant temperature went on following a frozen value and a dead hub looked healthy. After 30 failed polls in a row, about half a minute, the same count after which a wireless device that is not heard reads nothing, its readings are now forgotten and FanControl shows none until it answers again. FanControl stops driving a fan whose curve has no temperature, so the hub falls back to its own control. A shorter run of failures, such as the reopen after a wake, keeps the last readings.

fix: retry a controller that has gone at least every 30 seconds, timed on the clock

A faulted handle was reopened, and a controller a scan could not reach rebuilt, on a schedule that counted attempts: a first gap of 10 and a ceiling of 640. A wired hub offers about one a second, so one that had been gone a few minutes was tried only every five to eleven minutes, and one plugged back in could stay uncontrolled that long. A wireless pair offers several a second, so the same schedule ran faster for it. The schedule is now timed in milliseconds on the monotonic clock the call gate already uses: the first try at once, the next after five seconds as before, doubling to at most 30 seconds between tries. A controller plugged back in is driven again within about half a minute.

Full changelog: v1.1.43...v1.1.44


Built from commit 9259cd372a765d8d0a87df67dae2251e47cb53ae.