Repository navigation
ArSee v3.6.16 — Signal Map workbench and Windows engineering test release
Windows x64 · Source-qualified stable release preparation · 18 November 2026.
Publication is not established by this notes file. Official Windows Setup/portable ZIP, SHA-256, SBOM, provenance and an immutable v3.6.16 tag must first pass the exact-source Package workflow. Until then, v3.6.15 remains the previously verified public stable version.
Signal Map: grid-first engineering workflow
Changes since v3.6.15 on the current master source:
- #248: find by exact CA/IOA, signal name, bay, TYPE or mnemonic; combine bay/kind filters; an eight-column daily grid with optional advanced columns; explicit BAY TYPE + TYPE + MNEMO (+ existing number) name composition. Exact numeric IOA search prefers the primary point over command feedback references.
- #250: Excel-style direct cell edit, copy/paste TSV, multi-cell selection, Fill Down and Undo/Redo. Pasted batches are validated against a staged profile and rejected atomically for malformed, out-of-range or invalid IEC data. Esc restores native WPF cell edits.
- #251: grid-first layout. A compact header/search/action row gives the DataGrid maximum working area; the resizable Details inspector opens on demand with
Ctrl+Iinstead of permanently narrowing the grid. - #252: toolbar Material vector icons and exactly the same action-pill, primary-pill, icon-only and search-shell WPF style resources as Main Window.
- #253: Scaling/Mapping use the same shared toggle-pill styling and Material icons, with consistent field spacing, centered content and compact inspector controls.
For analog TI9/10/11/12/13/14/21/34/35/36, the Scaling page continues to expose Unit and either Factor or TwoPoint; X0/X100/Y0/Y100 remain above the fold in tested CI viewport. Digital/command points open Mapping. User-owned JSON profiles, command policy, IEC source identity, raw frame/quality evidence and Save & Apply semantics remain unchanged.
Field evidence worksheet (included in source)
Signal Map → More → Export blank Field FAT worksheet... creates an Excel-compatible UTF-8 CSV from the validated current Signal List. It records mapped identity and active scaling parameters while leaving independent field observations, calibration authority and evidence references blank with result NOT TESTED. Export is not a calibration approval or a command action. Reference field FAT matrix.
Evidence and safety boundaries
The merged GUI PRs passed Windows Release compilation, formatting, protocol smoke, xUnit, native WPF screen/interaction tests, CodeQL and repository hygiene on their reviewed heads. This release additionally requires exact merged master Windows CI, self-contained executable GUI probe, independent installed-updater FAT, Package asset verification, SHA-256 checksums, SBOM and provenance. Source-PR green checks alone do not satisfy the release workflow.
No physical IEC-101/104 RTU or SCADA FAT is claimed. Signed TI11 Q counts must not be displayed as MVar without independently approved RTU scaling (see #243); a 1200-bps SOE stress test requires physical FIFO/wire evidence. Open IEC-101 reliability work in #145 is not merged and not included in this release. Never perform active command/GI, serial-control or clock changes on a production link without site authorization.
Distribution
When the Package workflow succeeds, use its official v3.6.16 GitHub Release assets:
ARIEC60870-v3.6.16-setup-win-x64.exe— installer for managed Windows use.ARIEC60870-v3.6.16-win-x64.zip— self-contained portable Windows application.SHA256SUMS.txt, SPDX SBOM and published build provenance.
Do not reuse an older v3.6.16 tag for different source bytes or advertise those download paths before publication succeeds.