Repository navigation
ARIEC60870 v3.6.17
ArSee v3.6.17 — Public stable Windows software release
Windows x64 · Public stable software release candidate · 19 November 2026
This note describes the scope intended for the new stable v3.6.17. A release is not public just because this file or the source version exists. Official release status requires exact-source Windows CI, independently verified installed-updater FAT, Package build, checksums, SBOM, provenance and a published immutable v3.6.17 GitHub tag. Until those succeed, the latest stable remains v3.6.16 and v3.6.17-rc.7 remains a public prerelease.
Operator workflow improvements since v3.6.16
- Events / FC10–FC11: concise “Class 1 Data Polling” / “Class 2 Data Polling” hints. The label applies only to observed, qualified request/response polling and does not claim the IEC class of any IOA. Original TX/RX evidence and CSV
RequestFCremain authoritative. - Latest Event: its highlighted state follows actual auto-scroll/follow behavior, including user scroll and selection changes. It does not change event acquisition, ordering or retention.
- Simpler tooltips: frequently used actions have short, clear labels; source-backed IOA/address/quality/forensic details remain intact rather than being truncated. The short-tooltip policy is maintained in
AGENTS.md. - Bilingual IEC handbook / Help Center: unified English/Indonesian learning and Signal Map guidance, concise operator-oriented workflow, and Help WPF acceptance. Real OS DPI operator qualification at 125%/150% is still separate.
- Signal Map: grid-first editor, filter/find, atomic multi-cell editing, Fill Down, Undo/Redo, opt-in Scaling/Mapping inspector, explicit Save/Apply. Source identity/quality and project-owned mapping remain unchanged.
- Station reference safeguards: the 31-point demonstration profile and optional Q reference previews distinguish TI11 signed raw counts from unapproved MVar scaling; separately keep POAQ TI9 feedback 0–1200 and POOP TI48 outbound command metadata 0–1000. No universal station scaling is asserted.
- Website: bilingual GitHub Pages landing, guided demo, FAQ and download pages were synchronized with the latest published RC, with the last stable channel clearly labeled. Post-publication Pages metadata must be updated to reference the successful stable v3.6.17 assets.
Qualification and scope boundaries
This public software stability designation denotes the published reproducible Windows installer/ZIP and source-bound software tests; it is not IEC conformance certification or physical RTU/SCADA acceptance.
The v3.6.17 release pipeline must demonstrate:
- Exact merged source version 3.6.17, Windows Release build, C# format gate, protocol smoke, full xUnit and GUI/WPF evidence tests.
- Independent genuine installed-updater/previous-release FAT on the same exact master commit, not an older RC or synthetic-only test.
- Release Package verification of the self-contained application, installer, portable ZIP, checksums, SPDX SBOM and provenance; no tag/asset overwrite.
Physical field FAT remains NOT TESTED: actual SICAM A8000/other IED interoperability, real 1200-bps SOE/FIFO and failover, independent TI11 Q counts-to-MVar calibration, physical 100%/125%/150% Windows DPI acceptance, and authorized GI/SBO command behavior. Keep any customer station topology and captures private. Do not operate a second active Master on production lines.
See v3.6.17 RC.7 scope, field FAT worksheet, and IEC field implementation draft #145 (unmerged). Do not claim pending #145 changes are in the product.
Official distribution (after publication)
The release Package must publish and verify these exact assets:
ARIEC60870-v3.6.17-setup-win-x64.exe— per-user Windows x64 Inno Setup installer.ARIEC60870-v3.6.17-win-x64.zip— self-contained portable Windows x64.ARIEC60870-v3.6.17-sbom.spdx.json— dependency inventory.SHA256SUMS.txt— integrity checks.
The installer is unsigned; compare the published SHA-256, follow organizational software installation policies, and use only authorized/isolated test equipment.