Repository navigation
Releases
OpenTiaToolkit 1.0.0-preview.10 (unsigned preview)
OpenTiaToolkit 1.0.0-preview.10
Unsigned prerelease for Siemens TIA Portal V21. This build is available for wider testing. Windows may show an unknown-publisher warning.
Highlights
- Capture WinCC Unified Next Gen editor screenshots through CLI or MCP, including after a screen patch and without compiling the project.
- Create Unified HMI tag tables and exchange simple tags using native WinCCML with type and PLC binding verification.
- Inspect and compare AutomationML AR APC exports and reconcile supported additions in existing projects.
- Apply the alarm batch, HMI editing, nested PLC and VCI document, and hardware rollback improvements since preview.9.
Install and test
Download OpenTiaToolkit-1.0.0-preview.10-Setup.exe, INSTALLER-SHA256SUMS.txt, and UNSIGNED-NOTICE.txt from this release. Verify the checksum, install with Siemens Openness worker registration enabled, then run version and doctor. Begin write testing on disposable project copies.
The installer passed local acceptance on Windows 10 with TIA V21 Update 2, including HMI capture, screen patch readback, and a WinCCML round trip. AutomationML parsing was checked with the installed CLI. Independent-machine acceptance and live AutomationML reconciliation remain open for wider testing.
OpenTiaToolkit 1.0.0-preview.9 (unsigned preview)
OpenTiaToolkit 1.0.0-preview.9 — unsigned preview
TIA Portal V21 only. The installer and product binaries are unsigned. Download the installer together with INSTALLER-SHA256SUMS.txt and UNSIGNED-NOTICE.txt, and verify its SHA-256 before running it.
Changes
- Reject conflicting shared HMI trend archive settings before any bulk writes, in preview and apply.
- Filter HMI screen paths before metadata projection and PLC block names before expensive metadata reads.
- Reuse PLC target discovery only within one impact analysis, retaining fresh consumer evidence at planning, approval, and apply.
- Compile the fully restored PLC program before verifying type rollback hashes.
- Reduce repeated Unified discrete-alarm preflight reference reads.
Validation
903 tests passed, plus three disposable real-TIA campaigns comprising 252 command round trips on the exact installer-extracted worker. Forced compile failure, proven rollback, stale-state guards, inverse cleanup, and fresh-session verification passed. Packaged CLI/MCP discovery, a live MCP blueprint/archive/reset smoke, API compatibility, installer integrity, checksums, SBOM/provenance, and hosted CI passed.
See VALIDATION_PREVIEW9.md for exact identities, tested scope, and explicit limits. Historical preview.8 independent acceptance does not certify every preview.9 workflow. No physical download or runtime behavior is claimed.
Binary/source commit: 98646dd. Release notes.
Installer SHA-256: 19125150009070d804d35cd279a6a093906c01767dd5b95b68b821e5c571a9bb.
Assets include the Windows installer, portable Agent Plugins ZIP, Claude Desktop MCPB, exact source archive, validation record, checksums, SBOM, and provenance. Siemens binaries and private project data are excluded.
OpenTiaToolkit 1.0.0-preview.8 (unsigned preview)
OpenTiaToolkit 1.0.0-preview.8 — unsigned preview
OpenTiaToolkit is now public. This Windows CLI/MCP preview targets TIA Portal V21 only, with 186 engineering commands and three MCP infrastructure tools. It is unsigned: verify checksums before running Setup and begin write workflows on disposable copies with independent backups.
Downloads and setup
- Windows installer, installer SHA-256, unsigned notice
- Portable Agent Plugin and Claude Desktop MCPB
- Quick start, setup, qualification matrix
Installer SHA-256:
489efe254f935bf3782eb3a70f15fab9583911c4f8fcb59121b75ac943065d16
Install legitimate Siemens components/licenses and .NET Framework 4.8, ensure Siemens TIA Openness group membership, and keep exact-worker registration selected in Setup. Run installed version and doctor, then configure one OpenTia integration in your client. A healthy doctor does not qualify licensing or every workflow on a changed Siemens update.
What changed
Device-creation previews now execute on an archived saved project copy in a separately owned TIA instance, then discard that copy. This avoids the preview/apply Unified session-loss sequence observed in preview.7. The selected project is never automatically saved or closed; unsaved/unsupported snapshots fail explicitly. Session-loss reads require explicit recovery, failed transactions distinguish attempted rollback from completion, and new worker registrations preserve existing entries. Installed sibling-worker discovery, compatible binary-drift warnings and catalog/error corrections are included.
Qualified scope and limits
Independent installed acceptance passed for first-install/client/CPU compile/inverse on V21 Update 3; repeated Unified provisioning and scoped screen/item editing with human HMI software compilation on Update 2 Hotfix 1; and G120C PN Main telegram number/address preview/apply/persistence/inverse on the measured Startdrive V21 Update 1 binary. Release build/tests, vendor-free CI and packaged protocol checks passed. See the matrix and sanitized validation record for exact identities and evidence.
- Historical user TIA process departures remain unexplained; Toolkit causation is not established. One controlled MCP-owned isolation cycle reproduced no cross-instance loss.
- Uninstall can retain Siemens registration/client state; complete immediate root removal was not proven on one first-use PC.
compile-softwareis PLC-only. HMI compile evidence is human TIA UI evidence; runtime behavior and a real mid-batch HMI apply-failure control are unqualified.- Startdrive compile transcripts show zero errors and the same 14 existing warnings. Dedicated drive compilation is not independently captured and project-wide IO coverage is incomplete. Broader commissioning/safety/drive-family workflows are unqualified.
- Other exposed domains, runtime/simulator behavior and physical downloads are outside this scoped acceptance. No Siemens software or official manuals are bundled.
Accepted binary/source commit: 7e8c5820ea5df7beb9afc4225575bf064af30cce. Installer, source archive and plugin bundle bytes remain those independently accepted snapshots; current repository guidance and validation supplement their earlier documentation. No rebuild or repack was performed for publication. Preview.6 and preview.7 remain unpublished historical drafts.
Report ordinary bugs through issues; use private vulnerability reporting for security issues. Do not attach credentials, proprietary projects or Siemens binaries.
Public publication verification passed: all 14 assets downloaded without credentials, checksums/signature state verified, fresh public MCPB read-only diagnostics/tool execution and modern/legacy protocol smoke passed with 189 tools. No installation or live project campaign was repeated. See the validation asset for exact scope and the CLI-host distinction.