OpenTiaToolkit 1.0.0-preview.8 (unsigned preview)

Pre-release
Pre-release

Choose a tag to compare

@mistik91 mistik91 released this 11 Oct 13:59

OpenTiaToolkit 1.0.0-preview.8 — unsigned preview

OpenTiaToolkit is now public. This Windows CLI/MCP preview targets TIA Portal V21 only, with 186 engineering commands and three MCP infrastructure tools. It is unsigned: verify checksums before running Setup and begin write workflows on disposable copies with independent backups.

Downloads and setup

Installer SHA-256:

489efe254f935bf3782eb3a70f15fab9583911c4f8fcb59121b75ac943065d16

Install legitimate Siemens components/licenses and .NET Framework 4.8, ensure Siemens TIA Openness group membership, and keep exact-worker registration selected in Setup. Run installed version and doctor, then configure one OpenTia integration in your client. A healthy doctor does not qualify licensing or every workflow on a changed Siemens update.

What changed

Device-creation previews now execute on an archived saved project copy in a separately owned TIA instance, then discard that copy. This avoids the preview/apply Unified session-loss sequence observed in preview.7. The selected project is never automatically saved or closed; unsaved/unsupported snapshots fail explicitly. Session-loss reads require explicit recovery, failed transactions distinguish attempted rollback from completion, and new worker registrations preserve existing entries. Installed sibling-worker discovery, compatible binary-drift warnings and catalog/error corrections are included.

Qualified scope and limits

Independent installed acceptance passed for first-install/client/CPU compile/inverse on V21 Update 3; repeated Unified provisioning and scoped screen/item editing with human HMI software compilation on Update 2 Hotfix 1; and G120C PN Main telegram number/address preview/apply/persistence/inverse on the measured Startdrive V21 Update 1 binary. Release build/tests, vendor-free CI and packaged protocol checks passed. See the matrix and sanitized validation record for exact identities and evidence.

  • Historical user TIA process departures remain unexplained; Toolkit causation is not established. One controlled MCP-owned isolation cycle reproduced no cross-instance loss.
  • Uninstall can retain Siemens registration/client state; complete immediate root removal was not proven on one first-use PC.
  • compile-software is PLC-only. HMI compile evidence is human TIA UI evidence; runtime behavior and a real mid-batch HMI apply-failure control are unqualified.
  • Startdrive compile transcripts show zero errors and the same 14 existing warnings. Dedicated drive compilation is not independently captured and project-wide IO coverage is incomplete. Broader commissioning/safety/drive-family workflows are unqualified.
  • Other exposed domains, runtime/simulator behavior and physical downloads are outside this scoped acceptance. No Siemens software or official manuals are bundled.

Accepted binary/source commit: 7e8c5820ea5df7beb9afc4225575bf064af30cce. Installer, source archive and plugin bundle bytes remain those independently accepted snapshots; current repository guidance and validation supplement their earlier documentation. No rebuild or repack was performed for publication. Preview.6 and preview.7 remain unpublished historical drafts.

Report ordinary bugs through issues; use private vulnerability reporting for security issues. Do not attach credentials, proprietary projects or Siemens binaries.

Public publication verification passed: all 14 assets downloaded without credentials, checksums/signature state verified, fresh public MCPB read-only diagnostics/tool execution and modern/legacy protocol smoke passed with 189 tools. No installation or live project campaign was repeated. See the validation asset for exact scope and the CLI-host distinction.