Repository navigation
OpenTiaToolkit 1.0.0-preview.8 (unsigned preview)
Pre-releaseOpenTiaToolkit 1.0.0-preview.8 — unsigned preview
OpenTiaToolkit is now public. This Windows CLI/MCP preview targets TIA Portal V21 only, with 186 engineering commands and three MCP infrastructure tools. It is unsigned: verify checksums before running Setup and begin write workflows on disposable copies with independent backups.
Downloads and setup
- Windows installer, installer SHA-256, unsigned notice
- Portable Agent Plugin and Claude Desktop MCPB
- Quick start, setup, qualification matrix
Installer SHA-256:
489efe254f935bf3782eb3a70f15fab9583911c4f8fcb59121b75ac943065d16
Install legitimate Siemens components/licenses and .NET Framework 4.8, ensure Siemens TIA Openness group membership, and keep exact-worker registration selected in Setup. Run installed version and doctor, then configure one OpenTia integration in your client. A healthy doctor does not qualify licensing or every workflow on a changed Siemens update.
What changed
Device-creation previews now execute on an archived saved project copy in a separately owned TIA instance, then discard that copy. This avoids the preview/apply Unified session-loss sequence observed in preview.7. The selected project is never automatically saved or closed; unsaved/unsupported snapshots fail explicitly. Session-loss reads require explicit recovery, failed transactions distinguish attempted rollback from completion, and new worker registrations preserve existing entries. Installed sibling-worker discovery, compatible binary-drift warnings and catalog/error corrections are included.
Qualified scope and limits
Independent installed acceptance passed for first-install/client/CPU compile/inverse on V21 Update 3; repeated Unified provisioning and scoped screen/item editing with human HMI software compilation on Update 2 Hotfix 1; and G120C PN Main telegram number/address preview/apply/persistence/inverse on the measured Startdrive V21 Update 1 binary. Release build/tests, vendor-free CI and packaged protocol checks passed. See the matrix and sanitized validation record for exact identities and evidence.
- Historical user TIA process departures remain unexplained; Toolkit causation is not established. One controlled MCP-owned isolation cycle reproduced no cross-instance loss.
- Uninstall can retain Siemens registration/client state; complete immediate root removal was not proven on one first-use PC.
compile-softwareis PLC-only. HMI compile evidence is human TIA UI evidence; runtime behavior and a real mid-batch HMI apply-failure control are unqualified.- Startdrive compile transcripts show zero errors and the same 14 existing warnings. Dedicated drive compilation is not independently captured and project-wide IO coverage is incomplete. Broader commissioning/safety/drive-family workflows are unqualified.
- Other exposed domains, runtime/simulator behavior and physical downloads are outside this scoped acceptance. No Siemens software or official manuals are bundled.
Accepted binary/source commit: 7e8c5820ea5df7beb9afc4225575bf064af30cce. Installer, source archive and plugin bundle bytes remain those independently accepted snapshots; current repository guidance and validation supplement their earlier documentation. No rebuild or repack was performed for publication. Preview.6 and preview.7 remain unpublished historical drafts.
Report ordinary bugs through issues; use private vulnerability reporting for security issues. Do not attach credentials, proprietary projects or Siemens binaries.
Public publication verification passed: all 14 assets downloaded without credentials, checksums/signature state verified, fresh public MCPB read-only diagnostics/tool execution and modern/legacy protocol smoke passed with 189 tools. No installation or live project campaign was repeated. See the validation asset for exact scope and the CLI-host distinction.