Repository navigation
orcad2kicad 1.0.6: PADS board solder mask cleanup / PADS 보드 솔더마스크 정리
orcad2kicad 1.0.6
한국어 설명은 아래에 있습니다.
Feature release of orcad2kicad, an open-source tool (MIT) that converts OrCAD schematics (EDIF/.DSN) into KiCad 10.0 projects and verifies them against a reference netlist. When a PADS board (--board .asc) is supplied, the solder mask that the KiCad PADS board importer transfers incorrectly is corrected from the CAM settings in the PADS file. The schematic and its connections (nets) do not change.
What's new
- Missing pad mask openings restored. PADS creates an opening when the CAM solder mask document draws the pad, even if the padstack has no mask, but the importer does not read this setting, so through-hole pad openings were missing or missing on the back side only.
F.Mask/B.Maskare filled in according to the CAM document (vias only on sides where the CAM document draws copper vias). All 159 through-hole pads on the example board have front and back openings. - Importer's fixed mask clearance corrected. The importer writes the number 3 into
pad_to_mask_clearancein file units, which is 3 mm in a metric PADS file (openings 6 mm larger than the pad). Only this fixed value is changed to 0 (the KiCad default). The PADS CAM pad oversize is not applied and is reported in the log andauto_changes.txt(applied as is, it can remove the mask between IC pins at 0.5 to 0.65 mm pitch). - Documentation drawings moved off the mask. The importer sends UNASSIGNED PADS layers 25/28 to
F.Mask/B.Mask, so drawings such as decal outlines became mask openings. Only drawings whose coordinates and line width match a decal piece are moved toCmts.User(10 on the example board, KiCad DRC mask violations 199 → 0). - Reporting. The
board mask:log line, thePCB:item inAUTO CHANGES, andauto_changes.txt. EDIF input now reports automatic changes too. Use--keep-board-masksto turn this off. When a.kicad_pcbis given directly, nothing is changed and only the number of pads without openings is reported as a warning.
Compared with private production PADS boards and their PADS fabrication Gerbers: opening positions match 90/90 on front and back (20/56 before cleanup). Before fabrication, we recommend overlaying the KiCad mask Gerber on the PADS mask Gerber (User Manual section 4.5).
Download
- Windows 64-bit executables:
orcad2kicad-1.0.6-win64.zip(GUIorcad2kicad.exe+ CLI/MCPorcad2kicad-cli.exe) - From source (Windows/Linux/macOS):
git clone, then see README.en.md
Integrity check (SHA-256)
SHA256(orcad2kicad-1.0.6-win64.zip) = 23c08a9e8f9239131df2e630d227941eca97c872242dbfe205411f267fd50198
PowerShell: Get-FileHash orcad2kicad-1.0.6-win64.zip -Algorithm SHA256
Requirements
Windows exe, or Python 3.10+ from source (Windows/Linux/macOS). Normal use needs stable KiCad 10.0.
Reading a .DSN without OrCAD needs a KiCad nightly, which the "prepare portable nightly" feature sets up without installing anything.
See README.en.md, docs/Quick_Start.en.md and docs/User_Manual.en.md for usage.
orcad2kicad 1.0.6
OrCAD 회로도(EDIF/.DSN)를 KiCad 10.0 프로젝트로 변환하고 기준 넷리스트로 검증하는 오픈소스 도구(MIT)의
기능 릴리스입니다. PADS 보드(--board .asc)를 함께 줄 때, KiCad PADS 보드 임포터가 틀리게 옮기는 솔더마스크를
PADS 파일 안의 CAM 설정대로 바로잡습니다. 회로도와 연결(넷)은 바뀌지 않습니다.
무엇이 새로운가
- 빠진 패드 마스크 개구 복원. PADS 는 패드스택에 마스크가 없어도 CAM 솔더마스크 문서가 패드를 그리면 개구를
만들지만, 임포터는 이 설정을 읽지 않아 스루홀 패드 개구가 없거나 뒷면만 빠졌습니다. CAM 대로F.Mask/B.Mask를
채웁니다(비아는 CAM 이 구리 비아를 그리는 면만). 예시 보드 스루홀 159개 전부 앞·뒤 개구. - 임포터 고정 마스크 여유값 교정. 임포터는
pad_to_mask_clearance에 숫자 3 을 파일 단위 그대로 넣습니다 — 미터
단위 PADS 파일이면 3 mm(개구가 패드보다 6 mm 크게). 이 고정값일 때만 0(KiCad 기본값)으로 바꾸고, PADS CAM 패드
오버사이즈는 적용하지 않고 로그·auto_changes.txt로 알립니다(그대로 넣으면 0.5~0.65 mm 피치 IC 핀 사이 마스크가
사라질 수 있음). - 마스크로 들어간 문서용 그림 이동. 임포터는 용도 미지정(UNASSIGNED) PADS 레이어 25/28 을
F.Mask/B.Mask로
보내, 디칼의 외곽선 같은 그림이 마스크 개구가 됐습니다. 디칼 조각과 좌표·선폭이 맞는 그림만Cmts.User로
옮깁니다(예시 보드 10개, KiCad DRC 마스크 위반 199 → 0). - 고지. 로그
board mask:줄,AUTO CHANGES의PCB:항목,auto_changes.txt. EDIF 입력에서도 자동 변경을
알립니다. 끄려면--keep-board-masks..kicad_pcb를 직접 주면 고치지 않고 개구 없는 패드 수만 경고합니다.
비공개 실무 PADS 보드와 그 PADS 제조 거버로 대조: 개구 위치 앞·뒤 90/90 일치(정리 전 20/56).
제조 전에는 KiCad 마스크 거버를 PADS 마스크 거버와 겹쳐 보는 것을 권합니다(사용자설명서 4.5절).
다운로드
- Windows 64비트 실행 파일:
orcad2kicad-1.0.6-win64.zip(GUIorcad2kicad.exe+ CLI/MCPorcad2kicad-cli.exe) - 소스에서 실행(Windows/Linux/macOS):
git clone후 README.md 참조
무결성 확인 (SHA-256)
SHA256(orcad2kicad-1.0.6-win64.zip) = 23c08a9e8f9239131df2e630d227941eca97c872242dbfe205411f267fd50198
PowerShell: Get-FileHash orcad2kicad-1.0.6-win64.zip -Algorithm SHA256
요구 사항
Windows exe 또는 Python 3.10+ (Windows/Linux/macOS, 소스에서 실행). 일반 사용에는 정식(stable) KiCad 10.0.
.DSN 을 OrCAD 없이 읽으려면 KiCad 나이틀리(도구 내 "나이틀리 포터블 준비" 기능으로 설치 없이 준비 가능).
자세한 사용법은 README.md 및 docs/Quick_Start.md, docs/사용자설명서.md 를 참조하십시오.