v4.4.0 (2024-05-06)
Implemented enhancements:
- Update weasis-dicom-tools and dcm4che to 5.32.0 #547
- Replace OSGI Sling logger by Logback 1.5.2 and update to slf4j 2.0.12 #540
- Update to weasis-core-img 4.9.0.1 #539
- Update to FlatLaf 3.4.1 #538
Fixed bugs:
- Image editor tools are not visible with Dicomizer #546
- Issue of removing series from the UI #544
- Segmentation panel is sometimes not visible when loading DICOM SEG #541
- MIP rebuild resets the image preset #528
- Can't open DX studies #525
Merged pull requests:
refs/tags/v4.3.0
Implemented enhancements:
- Fill opacity as a graphic property #505
- Cine for multiframe: variable speed and sweeping #497
- Improve tag viewer #494
- Merging several multiframe files with an identical concatenation UID #493
- Display an error message when a file is identified as DICOM but cannot be read #479
- Multiframe image fixed/varibale framerate (Frame Time Vector support 0018,1065) #424
- Color and transparency display options for overlay data #184
Fixed bugs:
- 3D Buttons are not active #504
- The latest measurement values are not visible in the table #502
- font size setting of Labels on image does not affect actually. #498
Closed issues:
- Weasis does not even reach the splash screen - possible wayland and flatpak interaction? #449
v4.2.1
v4.2.1 (2023-11-11)
Implemented enhancements:
- Update to Flatlaf 3.2.5 #490
- Update weasis-dicom-tools and dcm4chee to 5.31.1 #489
- Patient/Study/Series/Image navigation via keyboard shortcuts #483
- (0018,1114) EstimatedRadiographicMagnificationFactor is not used when performing measurements #465
- Use arrow keys to scroll inside stack and change series #235
Fixed bugs:
- Wrong color rendering of jpeg2000 with YBR_FULL #491
- Wrong color rendering of jpeg2000 with YBR_FULL color model #488
- Issue of parsing some properties in JSON files #481
- 4.2.0 .rpm does not install on Fedora 38, looking for already installed dependencies #467
- NULL UICore Instance access problem at UICore Constructor #466
- Cannot open any images with wayland #462
v4.2.0
v4.2.0 (2023-08-18)
Implemented enhancements:
- Use JSON file instead of properties for weasis configuration (Part 1) #454
- Synchronize views from different tabs #433
- Add shortcut to close current patient/image with "Ctrl+W" #429
Fixed bugs:
- The clickable area of the key images does not match with the button size #458
- Error in docking framework when opening or closing a tab #452
- Cannot read RT ion plan and display Isodoses #446
- DICOM explorer does not show all the series when large number of series are loaded #443
- RT tool is not closed when closing the view tab #440
- Clicking on RT Dose open images in new Weasis instance #439
- Cannot enable again OpenGL in Preferences #438
- Persistence of drawing tools and overlays doesn't work #435
- Unable to load OpenCV native library on Windows #431
v4.1.2
v4.1.2 (2023-06-16)
Fixed bugs:
- Languages can no longer be changed from the UI #426
- Application freezes when 3D view is closed #425
- Value of shininess is out of range #423
- Cannot activate or deactivate OpenGL from Preferences #421
- Can't uninstall package weasis_4.0.3-1_amd64 #419
- Can't load 3D CT scan with odd size #414
Closed issues:
- PROBLEM: Weasis can't find my graphic card #420
v4.1.1
v4.1.0
v4.1.0 (2023-05-08)
Implemented enhancements:
- Preference for opening the MPR in a certain layout #406
- Some viewers do not support the drag and drop of a series #405
- DICOM ECG measurement #403
- Persistence of search criteria in the Q/R #400
- Open log folder from the Help menu #398
- MPR auto-center options #397
- Remove popup confirmation for some browsers #396
- Activate DICOM RT tool panel when loading DICOM RT files #395
- Add specific message when DICOM Q/R exceeds the limit of the results #392
- 3D View - Volume Rendering - Part 1 #389
- Keep the state of the docking panel when switching to a different viewer #381
- LUT in Enhanced CT is not applied #375
- Radiograph images suddenly become very bright after slightly lower the window level in Weasis #373
- Using crosshair resets zoom on images #371
- Option for sorting studies #369
Fixed bugs:
- The control points of the ellipse are not always displayed #404
- SUVbw value are different for DRO Washington Image than required per QIBA profile #399
- Thumbnails in DICOM Explorer are not aligned correctly #391
- Localization does not work for weasis-core-api and weasis-core-ui in Weasis-snapshot after version 4.0.3. #386
- Weasis and Dicomizer don't start maximized within Compiz (in MX-Linux) #383
- Cannot load DICOM DX with invalid patient orientation #376
- LUT (black/white colour scales) of some plain radiographs becomes inverted after upgrading to Weasis 4.0.3 #372
- Viewer tabs behavior when opening studies via DICOM get #357
- A corrupted DICOM file crashes Weasis #350
Closed issues: