Whats new in v6.3.1

many many pure signal 3.0 fixes
Also fixed a bug where you could not adjust custom meters past 15watts with hermes lite connected
Went back to a single .msi installer no more bundled exe installer

PureSignal 3.0 - a short guide for the operator

  1. The Single Cal - measure once, keep the result

A Single Cal is ONE measurement. It runs a test signal, works out your
amplifier's distortion, applies the correction, and stops. The correction
stays applied until you switch PureSignal off.

How:

  1. In the linearity window, pick the stimulus in the "Cal Stimulus" box -
    "Two-Tone" or "Noise".
  2. Press "Single Cal".
  3. It keys up, measures for a second or two, and stops on its own. That's it.
  4. The correction stays applied. To switch PureSignal off, press the "OFF"
    button at the top right of the linearity window. Pressing "Single Cal"
    again does NOT turn it off - it just runs another calibration.

Which stimulus?

  • Noise - "how clean is my actual signal?" The guide by dr. warren pratt is clear that the
    noise test is the honest one, because it is the closest to speech.
  • Two-Tone - repeatable numbers you can compare before and after a change.

One gotcha: if you have not transmitted for a while, the FIRST press can
cancel itself. Just press it again, or start the TX test first (the
"Two-Tone" / "Noise" buttons in the linearity window do that).

In setup test tab:

  • Freq #1 / Freq #2 - the two tone frequencies. Press "Defaults" for
    700/1950 Hz. Do NOT use a spacing that is a neat fraction of 96 kHz 700/1900 the old defaults
    (1200 Hz is exactly 1/80 - the calibration then only sees a few repeated
    levels instead of a continuous sweep, and the correction comes out
    distorted).
  • AmpView - shows the measured gain curve and the correction curve.
  • Save / Restore - store a correction to a file and put it back later.
  • PS Correction (Strict / Medium / Relaxed) - how strict the calibration is
    about the data it is given.
  1. PS-A (auto-calibrate) - keep measuring for ever

PS-A is the button on the console. Tick it and PureSignal re-measures and
re-corrects CONTINUOUSLY, so it keeps up with the amplifier as it warms up, as
the band changes and as the power changes.

  • It needs you to transmit regularly - it can only measure while the
    transmitter is keyed.
  • Leave it on for normal operation.
  • PS-A and Single Cal are mutually exclusive: pressing Single Cal turns PS-A
    off, and PureSignal stays on with the correction it has just made.
  1. The console lights

There are two lights on the info bar at the bottom of the console.

"Feedback" - how hard your amplifier sample is coming back. A number plus a color:

green    just right, you are in the target band
yellow   close, but not quite
blue     TOO MUCH feedback
red      TOO LITTLE feedback

(left-click the info bar if you would rather have red and blue the other way
round)

"Pure Signal" / "Correcting" - dark means PureSignal is off. Green
"Correcting" means the correction is actually being applied.

Two things worth knowing:

  • Both lights only come on while you are TRANSMITTING. No TX, no lights.
  • With PS-A you get both - the feedback number ticks over and the light
    changes colour.
  • With a Single Cal you get ONLY the "Correcting" light. in the linerarity panel A Single Cal is a
    one-off, so a feedback number flashing on the console afterwards would
    only be stale information.
  1. The feedback level and the attenuator

The ATT on TX (the "ATT" setting) is the step attenuator in the transmit
path. It sits in the feedback measurement, so:

Every decibel of extra attenuation = one decibel less feedback reading.

The PureSignal engine has a "target feedback level". The auto-attenuator moves
the ATT on TX until the feedback reading sits on that target. For most radios
the target is 152, it is set in the program and you cannot change it - and you
should not try. A target the rig cannot reach makes the auto-attenuator park
on the end stop of the attenuator (31 dB) with a weak feedback signal, and the
light never goes green.

If you ever see the attenuator stuck at 31 dB with the feedback light yellow,
a wrong target is in use. Tell us, do not try to fix it by hand.

For the record: the feedback numbers under PureSignal 3 are the SAME as under
PureSignal 2 - with the target at 152 the attenuator and the output power land
exactly where they used to.

One caution: the attenuator is in the transmit path, so when it moves, the
drive into your amplifier changes by the same amount. Watch the ALC and the
power when the auto-attenuator walks it.

If you only remember three things

  1. The FB Target is set by the program (152)most radios.
  2. Feedback numbers under PureSignal 3 are the same as under 2. If the
    number and the green light disagree, suspect a wrong target, not a
    broken PureSignal.
  3. A Single Cal needs the TX test running if it cancels itself on the first
    press.

Installer

  • .msi — the SDR-VST3 product. It requires the .NET 10 Desktop
    Runtime
    (x64) to be installed on the machine. The installer checks
    for it and tells you where to get it if it is missing:
    https://dotnet.microsoft.com/download/dotnet/10.0

    If you already have an older SDR-VST3 installed, installing over it
    upgrades in place.