Skip to content

Real hardware

Ralf Steinert edited this page Nov 26, 2026 · 1 revision

Everything the station does goes through PyVISA and pyserial, so moving from the simulator to a real bench changes the configuration, not the code. None of this has run against a real fixture yet (see "Status" at the end) — treat it as a careful starting point, not as a validated station.

1. The instruments

Role What it must do Default commands
psu set voltage and current limit, switch the output, measure V and I VOLT, CURR, OUTP, MEAS:VOLT?, MEAS:CURR?
dmm DC voltage MEAS:VOLT:DC?
mux close one channel at a time, report its state ROUT:OPEN:ALL, ROUT:CLOS (@101), ROUT:CLOS? (@101)
scope (optional) single capture on a rising edge, waveform as bytes Keysight InfiniiVision: :SING, :OPER:COND?, :WAV:PRE?, :WAV:DATA?
console the board's serial console any pyserial URL

All SCPI instruments must also answer *IDN?, *RST and SYST:ERR?.

2. The resource strings

visa_backend: ""                     # NI-VISA / Keysight IO Libraries; "@py" for pyvisa-py
resources:
  psu: "USB0::0x2A8D::0x1002::MY12345678::INSTR"
  dmm: "TCPIP0::192.168.1.20::INSTR"
  mux: "TCPIP0::192.168.1.21::5025::SOCKET"
  scope: "TCPIP0::192.168.1.22::INSTR"
  console: "/dev/ttyUSB0"            # COM3 on Windows, socket://host:port for a terminal server
console_baudrate: 115200

python -m pyvisa info and pyvisa-shell show which resources your VISA library finds. Check each one by hand before the first run:

pyvisa-shell
(visa) open TCPIP0::192.168.1.20::INSTR
(TCPIP0::192.168.1.20::INSTR) query *IDN?

3. Instruments with another dialect

Many supplies use channel arguments, many switch units use other channel numbers. Derive a class from the driver in drivers.py, override only what differs, and name it in the config:

# my_drivers.py, next to my-station.yaml
from bench.drivers import PowerSupply

class RigolDP800(PowerSupply):
    """Channel 1 of a Rigol DP800."""
    def configure(self, voltage, current_limit):
        self.write(f":APPL CH1,{voltage:.3f},{current_limit:.3f}")
        self.check_errors()
    def output(self, on):
        self.write(f":OUTP CH1,{'ON' if on else 'OFF'}")
    def measure_voltage(self):
        return self.query_float(":MEAS:VOLT? CH1")
    def measure_current(self):
        return self.query_float(":MEAS:CURR? CH1")
drivers:
  psu: my_drivers.py:RigolDP800

The class must derive from the default driver of that role, and a wrong entry stops bench run before the supply is switched on. If scpi-sim has a profile of your model, try a new driver against it before you wire it to a board.

4. The fixture

The rails are measured one at a time through the multiplexer; the config says which channel goes to which test point and what the limits are:

rails:
  - {name: "5V0",  channel: 101, nominal: 5.0,  tolerance_pct: 5}
  - {name: "3V3",  channel: 102, nominal: 3.3,  tolerance_pct: 5}

The driver opens all channels before it closes the next one, and checks that the channel really closed. On a real fixture, check the wiring once with a known board and a handheld meter before trusting the readings.

For the scope, channel 1 sees the input current through a current probe (volts_per_amp is the probe's transfer factor), channel 2 one rail. Leave the scope section out until the probe is there; the station then runs without the scope values.

5. Limits and the device checks

The on-device checks run shell commands over the console (free -m, smartctl, lsusb, /sys/class/net/..., hwclock). The defaults fit the simulated board: change device.serial_pattern, bios_version, min_memory_mb, the USB test stick (vid_pid, expected_count), the Ethernet interface and the temperature limit to your product. The login user and prompt are in boot.user and boot.login_prompt.

6. The first runs

  1. Run with a known-good board and look at every measurement in report.html, not just the verdict. Tighten the limits from what good boards actually show.
  2. Record the golden log from that board (Golden boot log).
  3. Provoke a few real faults if you can — pull a USB stick, unplug Ethernet — and check that exactly the expected step fails.

Status

The sequence, the limits and the reports are tested end to end against the simulated board on Linux, Windows and macOS in CI. The drivers have not been run against real instruments: the scope commands follow Keysight InfiniiVision scopes, the others are common SCPI. Reports from real benches are welcome as issues.

Clone this wiki locally