BUSMASTER-NG 3.4.0 "Overdrive"

Choose a tag to compare

@teoCLMR teoCLMR released this 28 Oct 07:44
· 52 commits to master since this release

Second release of BUSMASTER-NG, the community fork of BUSMASTER 3.2.2.
Not affiliated with ETAS GmbH or Robert Bosch GmbH.

Download and install

Download BUSMASTER-NG_3.4.0_win32.zip below, extract it anywhere and start BUSMASTER.exe. No setup needed.

Requirements:

  • Windows 10 or 11 (32 or 64 bit). Windows 7 SP1 should work but has not been tested yet.
  • Microsoft Visual C++ 2013 Redistributable (x86) (most PCs already have it).
  • The driver of your CAN / LIN interface (PEAK, Vector, Kvaser, ETAS, Ixxat, ...).
  • Node simulation only: MinGW, 32 bit (see the wiki page Node simulation).

Updating from 3.3.0: window positions and the last configuration are stored per version, so load your configuration
once (File → Load).

What's new

Changes marked (not tested yet) are built but still waiting for a test: if you have the hardware, a short report
in the linked issue helps a lot.

Databases

  • Message window and Signal Watch show the value descriptions of CAN signals again ("Position control" instead
    of 3) (#1).
  • CAN database editor (#2): factor and offset kept with full precision (a factor of 0.0000001 is no longer saved
    as 0); physical minimum and maximum with decimals; no false "Maximum value cannot be less than minimum value"; the
    position of a signal (LSB, MSB, DBC start bit) is shown and the Motorola convention is explained; Save As keeps a
    path with a dot; the editor opens big enough and can be resized.

Node simulation

  • Works with a current MinGW (tested with WinLibs GCC 16.2.0, 32 bit); a MinGW folder next to BUSMASTER.exe is
    found automatically and missing parts are reported clearly (#4). The package now contains the files needed to
    build nodes.
  • J1939 nodes: SetTimeout declared with its right name (original PR 1136 by jogo-).

Configuration (not tested yet, #3)

  • Open and Save dialogs remember the last folder of each kind of file (configuration, DBC, database, log, nodes, ...).
  • The LIN driver and the visibility of the status bar are saved in the configuration.
  • No "Do you want to save?" on exit when nothing was changed.

Replay, test automation, diagnostics (not tested yet, #5)

  • Log files are replayed at their recorded speed (original PR 768 by PBjore).
  • The Test Suite Executor sends each signal with the right value (original PR 1116 by itiserik).
  • The UDS window also shows the response as ASCII text (original PR 1300 by saerpa).

Drivers (not tested yet: we have no such hardware)

  • Ixxat driver included again (built with the Ixxat VCI V4 SDK).
  • NSI: driver restored from the configuration, standard and extended frames (original PR 1137 by MelissaA74).
  • PEAK PLIN-USB with one LIN channel works (fix by janw-cz, original issue 1188).

User interface

  • Ribbon button with the BUSMASTER-NG logo, sharp at every display scale; readable Replay and node simulation
    output windows at high scale.

Package

  • License texts, node simulation files and CHANGELOG.md are in the zip.

Full list: CHANGELOG.md.

Known limitations

  • The database engine DBManager.dll is a closed binary of the original project: factor/offset with about 7
    significant digits at run time, IEEE float signals shown as raw values, no CAN FD messages in databases,
    multiplexed signals always all shown.
  • Diagnostics (UDS) settings and J1939 Transmit window data are not saved in the configuration yet (#6).
  • Japanese resources are not maintained; the help still has images of the original BUSMASTER.

Problems? Open an issue (English or Italian).

SHA-256 of the zip: 7F8E47EB981D1B255126513F8B13E3392ED6D52957C1221A0172D3276A9BB1E9