Repository navigation
BUSMASTER-NG 3.4.0 "Overdrive"
Second release of BUSMASTER-NG, the community fork of BUSMASTER 3.2.2.
Not affiliated with ETAS GmbH or Robert Bosch GmbH.
Download and install
Download BUSMASTER-NG_3.4.0_win32.zip below, extract it anywhere and start BUSMASTER.exe. No setup needed.
Requirements:
- Windows 10 or 11 (32 or 64 bit). Windows 7 SP1 should work but has not been tested yet.
- Microsoft Visual C++ 2013 Redistributable (x86) (most PCs already have it).
- The driver of your CAN / LIN interface (PEAK, Vector, Kvaser, ETAS, Ixxat, ...).
- Node simulation only: MinGW, 32 bit (see the wiki page Node simulation).
Updating from 3.3.0: window positions and the last configuration are stored per version, so load your configuration
once (File → Load).
What's new
Changes marked (not tested yet) are built but still waiting for a test: if you have the hardware, a short report
in the linked issue helps a lot.
Databases
- Message window and Signal Watch show the value descriptions of CAN signals again ("Position control" instead
of 3) (#1). - CAN database editor (#2): factor and offset kept with full precision (a factor of 0.0000001 is no longer saved
as 0); physical minimum and maximum with decimals; no false "Maximum value cannot be less than minimum value"; the
position of a signal (LSB, MSB, DBC start bit) is shown and the Motorola convention is explained; Save As keeps a
path with a dot; the editor opens big enough and can be resized.
Node simulation
- Works with a current MinGW (tested with WinLibs GCC 16.2.0, 32 bit); a
MinGWfolder next toBUSMASTER.exeis
found automatically and missing parts are reported clearly (#4). The package now contains the files needed to
build nodes. - J1939 nodes:
SetTimeoutdeclared with its right name (original PR 1136 by jogo-).
Configuration (not tested yet, #3)
- Open and Save dialogs remember the last folder of each kind of file (configuration, DBC, database, log, nodes, ...).
- The LIN driver and the visibility of the status bar are saved in the configuration.
- No "Do you want to save?" on exit when nothing was changed.
Replay, test automation, diagnostics (not tested yet, #5)
- Log files are replayed at their recorded speed (original PR 768 by PBjore).
- The Test Suite Executor sends each signal with the right value (original PR 1116 by itiserik).
- The UDS window also shows the response as ASCII text (original PR 1300 by saerpa).
Drivers (not tested yet: we have no such hardware)
- Ixxat driver included again (built with the Ixxat VCI V4 SDK).
- NSI: driver restored from the configuration, standard and extended frames (original PR 1137 by MelissaA74).
- PEAK PLIN-USB with one LIN channel works (fix by janw-cz, original issue 1188).
User interface
- Ribbon button with the BUSMASTER-NG logo, sharp at every display scale; readable Replay and node simulation
output windows at high scale.
Package
- License texts, node simulation files and
CHANGELOG.mdare in the zip.
Full list: CHANGELOG.md.
Known limitations
- The database engine
DBManager.dllis a closed binary of the original project: factor/offset with about 7
significant digits at run time, IEEE float signals shown as raw values, no CAN FD messages in databases,
multiplexed signals always all shown. - Diagnostics (UDS) settings and J1939 Transmit window data are not saved in the configuration yet (#6).
- Japanese resources are not maintained; the help still has images of the original BUSMASTER.
Problems? Open an issue (English or Italian).
SHA-256 of the zip: 7F8E47EB981D1B255126513F8B13E3392ED6D52957C1221A0172D3276A9BB1E9