BUSMASTER-NG 3.7.5 "Overdrive"
Feature release: a new open source driver for the PEAK-System interfaces, on the PCAN-Basic API.
Note on updating
- Window positions and the last configuration are stored per version, so after updating from 3.6.0 load your
configuration once (File → Load).
Drivers
- New CAN driver PEAK PCAN-Basic for the PEAK-System interfaces (USB, PCI, PC Card, LAN), with open source code on
the PCAN-Basic API that comes with the PEAK device driver. It shows every PEAK channel of the PC in the hardware
selection, with the speeds of the drop-down list and the PEAK special ones (33.3, 47.6, 83.3, 95.2 kbit/s). Under
Advanced a channel can be put in listen-only mode: it only receives, without acknowledge or error frames, to watch
a bus. A channel open in PCAN-View can be connected as well. Received messages carry the time stamp of the interface.
If a channel cannot be started, the reason given by PEAK (for example the channel is used by another program) is
written in the trace window. The hardware list is read in a moment and shows the firmware of each interface. - The old PEAK driver (closed code from 2017) is now called PEAK USB (Legacy) and works as before; configurations
saved with PEAK USB still open with it. - The decoding of the error frames of the new driver (type of error and counters) is not tested yet: it needs a PEAK
interface on a bus with errors.
BUSMASTER-NG 3.6.0 "Overdrive"
Feature release: a Frequency (Hz) column in the Message and Transmit windows, a message list that can be sorted while
the bus is connected, messages that stop arriving shown in grey, repetition times that follow the clock, and updates
installed from inside BUSMASTER-NG.
Note on updating
- Window positions and the last configuration are stored per version, so after updating from 3.5.0 load your
configuration once (File → Load).
Message Window
- With the Simulation driver the Time column could show the wrong time in System Time (the time since the PC was
started instead of the time of day) after the first connect (#13). The reference time is now asked to the simulation
engine when the connection is made, and a driver that does not provide it no longer leaves random values (not
tested yet). - New Frequency (Hz) column (CAN): how often the messages with the same ID, channel and direction arrive, from the
time between them, averaged over the last messages ("-" for the first one). In append mode each row keeps the value
it had when it arrived. After the Data Byte(s) column, so a saved configuration keeps its columns; drag it where
you like. - Simulation driver: the time stamp of a message is taken when it is sent and not when the simulation engine hands it
to the clients. Messages sent every millisecond used to show intervals such as 1 ms and then 20 ms, because the
engine delivers them one at a time and a pause there bunched them together (the number sent per second was right);
Relative Time and Frequency (Hz) are now regular. Interfaces with real hardware are not affected, they time
stamp in the device. - CAN: the list can be sorted while the bus is connected (it only worked when disconnected), and in the overwrite mode
it stays sorted: click the header of ID (or Message, Channel, Time, Tx/Rx, Msg Type, DLC) once for
ascending and again for descending, and an ID that appears later goes to its place. Rows that are equal in the
column keep a fixed order (by ID, channel, direction). The sorting stays when the bus is connected again. In the
append mode, which is a trace in order of arrival, it still sorts only the messages already there, when disconnected. - CAN, LIN: the Data Byte(s) column opens narrower, enough for 8 bytes (its width came from a title padded with spaces;
a width saved in a configuration is kept). - CAN, overwrite mode: a message that stops arriving turns grey and its Frequency (Hz) shows "-", when nothing came
for three times its period (at least 100 ms); it goes back to normal when it comes again. A message seen only once
is never greyed, and on disconnecting the rows stay as they were. - CAN: the Frequency (Hz) column can be sorted too (in the overwrite mode the list is sorted when the header is
clicked and when an ID appears, the frequencies that change afterwards do not move the rows). - Connecting with messages already set to repeat in the Transmit window sometimes failed with "Failed to start the
hardware" (seen with Simulation): the Transmit window started sending before the hardware was started, kept the
driver busy and the start gave up. The Transmit window now starts once the hardware has started, with every driver
(with a real interface the first messages used to be sent to a controller not started yet), and the Simulation
driver also waits its turn instead of giving up. - CAN, sorted list (overwrite mode): the error frames kept their row after a sort (their row could take the place of a
message, or show another message's data); the Frequency (Hz) sort is made with the frequencies held still (they
changed during the sort and could leave it unsorted); Clear while connected no longer leaves rows pointing at the
wrong message (the error frames are not tested yet, they need a real interface).
Transmit window
- Messages sent with a repetition time (CAN and LIN) go out at the time you set: a message every 10 ms went out every
20 ms or less often, because the repetition was counted in wake-ups of the transmit thread (a wait of 1 ms lasts one
or two ticks of the system timer) and not in real time. It now follows the clock. - The shortest repetition time depends on Windows: 1 ms (1000 Hz) on Windows 10 1803 or later and Windows 11, which
have a high resolution timer, 2 ms (500 Hz) on Windows 7 and earlier Windows 10, where a wait of 1 ms lasts 1 to
2 ms. A shorter value is raised to the minimum, and the repetition time and the frequency shown in the list tell it.
On the fast timer a message that is late goes out again for the periods it missed (up to three in a row), so the
average rate holds. - New Frequency (Hz) column next to Repetition (ms) (CAN and LIN): type the repetition time and the frequency is
calculated, type the frequency (a comma is accepted as decimal separator) and the repetition time is calculated, in
the range 1 ms to 60 s.
Updates
- Help → Check for Updates installs a newer version from inside BUSMASTER-NG: Install now downloads the
installer (with a progress window and Cancel), checks it against the SHA-256 that GitHub gives for it, closes
BUSMASTER-NG (with the usual question about saving the configuration) and installs the update without the wizard;
BUSMASTER-NG starts again when it is done. Windows asks for administrator permission when BUSMASTER-NG is
installed for all users, not when it is installed only for you. Portable copies (zip) still get the release page. - Help → Check at Startup (off unless you turn it on): checks for a newer version every time BUSMASTER-NG starts,
in the background, and speaks up only when there is one.
BUSMASTER-NG 3.5.0 "Overdrive"
Feature release: a Hardware Selection dialog that is easier to use at high display scale, a baud rate list that
remembers the last speed, and a button to check for a new version.
Hardware selection (ETAS BOA, IntrepidCS neoVI, i-VIEW, IXXAT, Kvaser, MHS, NSI, Vector and VScom drivers)
- The columns of the lists scale with the display, so Channel 1 is no longer cut off at high display scale.
- The baud rate is a drop-down list of the usual speeds (10 kbit/s to 1 Mbit/s); another value can still be typed.
The last baud rate used with each interface is remembered for the next time, also when the configuration is not
saved: a channel that is still at the default 500 kbit/s starts with it, and so does a channel you add to the
list. Any other speed already set, for example by a loaded configuration, is kept. - Tested with the VScom driver; the dialog is shared by the other drivers, which were not tried one by one.
Help
- Help → Check for Updates asks GitHub for the latest release and, when it is newer than the running version,
opens its download page in the browser. Nothing is downloaded or installed by BUSMASTER-NG, and GitHub is
contacted only when you click the button.
Package
- Every executable and DLL built from the BUSMASTER-NG sources says product BUSMASTER-NG and the version of the
release in its file properties (Properties → Details); many still had the placeholders of the original project
("TODO: ", version 1.0.0.1) or no version at all. Needed for code signing.
Note on updating
- Window positions and the last configuration are stored per version, so after updating from 3.4.2 load your
configuration once (File → Load). The remembered baud rates are not part of it and are kept.
BUSMASTER-NG 3.4.2 "Overdrive"
Installer and packaging release: the program is the same as 3.4.1, with a clearer start-up message and the IXXAT
driver included.
Downloads
- An installer again,
BUSMASTER-NG_3.4.2_setup.exe, for Windows 7 SP1, 10 and 11: for all users or only for
you, with Start menu entries (BUSMASTER-NG, Format Converter, read-me), an optional desktop icon and an uninstaller.
It installs the Visual C++ 2013 runtime when it is missing and, on Windows 7 only, the Universal C runtime. - Two portable zips instead of one, with the same program:
_win32.zipfor Windows 10 / 11 (lighter: these
versions of Windows already have the Universal C runtime) and_win32_win7.zipfor Windows 7 SP1. - In the zips the licenses and the change log are in a
Docsfolder, so the main folder is tidier.Docsalso
containsTHIRD-PARTY-NOTICES.txtwith the licenses of the bundled components (libxml2, zlib, DMGraph, ...) and the
list of interface vendor libraries; build by-products (.mapfiles) are no longer included. - The IXXAT VCI driver (
CAN_IXXAT_VCI.dll) is in the package; it was missing because it needs the SDK of the
Ixxat VCI driver to be built. Not tested with real IXXAT hardware yet.
Start-up
- If the Microsoft Visual C++ 2013 Redistributable (x86) is not installed, BUSMASTER-NG says so, in Italian or
English, and offers to open the Microsoft download page, instead of the bare Windows error "msvcr120.dll is
missing".
Note on updating
- Window positions and the last configuration are stored per version, so after updating from 3.4.1 load your
configuration once (File → Load).
Project
- The release packages are built by GitHub Actions from the tagged sources (see the README).
BUSMASTER-NG 3.4.1 "Overdrive"
Bug fix release of BUSMASTER-NG, the community fork of BUSMASTER 3.2.2.
Not affiliated with ETAS GmbH or Robert Bosch GmbH.
Update recommended if you use the Simulation driver: 3.3.0 and 3.4.0 hang on the splash screen with it on a PC
where BUSMASTER was never installed (#7).
Download and install
Download BUSMASTER-NG_3.4.1_win32.zip below, extract it anywhere and start BUSMASTER.exe. No setup needed.
Requirements:
- Windows 10 or 11 (32 or 64 bit), or Windows 7 SP1 (start-up and Simulation driver tested on a clean Windows 7).
- Microsoft Visual C++ 2013 Redistributable (x86) (most PCs already have it).
- The driver of your CAN / LIN interface (PEAK, Vector, Kvaser, ETAS, Ixxat, ...).
- Node simulation only: MinGW, 32 bit (see the wiki page Node simulation).
Updating from 3.4.0: window positions and the last configuration are stored per version, so load your configuration
once (File → Load).
What's fixed
Reliability
- No more hang on the splash screen with the Simulation driver on a PC where BUSMASTER was never installed: the
simulation engineBusEmulation.exeis registered for the current user when needed (no administrator rights),
and if it still cannot start, a message says why (#7).
Configuration
- No "Do you want to save?" on exit when no configuration file is loaded (first start) and nothing was changed (#3).
User interface
- The main window no longer opens with its title bar above the top edge of the screen: it opens maximized the
first time, then as it was when closed, and a restored window always lies inside a monitor (#8). - The close button (X) of the Message Window hides it, like the Message Window button of the ribbon (#9).
- Message Window: the columns open wide enough for their titles at any display scale.
Full list: CHANGELOG.md.
Known limitations
- The database engine
DBManager.dllis a closed binary of the original project: factor/offset with about 7
significant digits at run time, IEEE float signals shown as raw values, no CAN FD messages in databases,
multiplexed signals always all shown. - Diagnostics (UDS) settings and J1939 Transmit window data are not saved in the configuration yet (#6).
- Some changes of 3.4.0 are still waiting for a test (#3, #5); the Ixxat, NSI and PLIN-USB fixes need hardware we
do not have. - Japanese resources are not maintained; the help still has images of the original BUSMASTER.
Problems? Open an issue (English or Italian).
SHA-256 of the zip: BAE19D4A0DF450A6392072AA36C3A60DFF313867A3AC906F2B8734727B84DDD7
BUSMASTER-NG 3.4.0 "Overdrive"
Second release of BUSMASTER-NG, the community fork of BUSMASTER 3.2.2.
Not affiliated with ETAS GmbH or Robert Bosch GmbH.
Download and install
Download BUSMASTER-NG_3.4.0_win32.zip below, extract it anywhere and start BUSMASTER.exe. No setup needed.
Requirements:
- Windows 10 or 11 (32 or 64 bit). Windows 7 SP1 should work but has not been tested yet.
- Microsoft Visual C++ 2013 Redistributable (x86) (most PCs already have it).
- The driver of your CAN / LIN interface (PEAK, Vector, Kvaser, ETAS, Ixxat, ...).
- Node simulation only: MinGW, 32 bit (see the wiki page Node simulation).
Updating from 3.3.0: window positions and the last configuration are stored per version, so load your configuration
once (File → Load).
What's new
Changes marked (not tested yet) are built but still waiting for a test: if you have the hardware, a short report
in the linked issue helps a lot.
Databases
- Message window and Signal Watch show the value descriptions of CAN signals again ("Position control" instead
of 3) (#1). - CAN database editor (#2): factor and offset kept with full precision (a factor of 0.0000001 is no longer saved
as 0); physical minimum and maximum with decimals; no false "Maximum value cannot be less than minimum value"; the
position of a signal (LSB, MSB, DBC start bit) is shown and the Motorola convention is explained; Save As keeps a
path with a dot; the editor opens big enough and can be resized.
Node simulation
- Works with a current MinGW (tested with WinLibs GCC 16.2.0, 32 bit); a
MinGWfolder next toBUSMASTER.exeis
found automatically and missing parts are reported clearly (#4). The package now contains the files needed to
build nodes. - J1939 nodes:
SetTimeoutdeclared with its right name (original PR 1136 by jogo-).
Configuration (not tested yet, #3)
- Open and Save dialogs remember the last folder of each kind of file (configuration, DBC, database, log, nodes, ...).
- The LIN driver and the visibility of the status bar are saved in the configuration.
- No "Do you want to save?" on exit when nothing was changed.
Replay, test automation, diagnostics (not tested yet, #5)
- Log files are replayed at their recorded speed (original PR 768 by PBjore).
- The Test Suite Executor sends each signal with the right value (original PR 1116 by itiserik).
- The UDS window also shows the response as ASCII text (original PR 1300 by saerpa).
Drivers (not tested yet: we have no such hardware)
- Ixxat driver included again (built with the Ixxat VCI V4 SDK).
- NSI: driver restored from the configuration, standard and extended frames (original PR 1137 by MelissaA74).
- PEAK PLIN-USB with one LIN channel works (fix by janw-cz, original issue 1188).
User interface
- Ribbon button with the BUSMASTER-NG logo, sharp at every display scale; readable Replay and node simulation
output windows at high scale.
Package
- License texts, node simulation files and
CHANGELOG.mdare in the zip.
Full list: CHANGELOG.md.
Known limitations
- The database engine
DBManager.dllis a closed binary of the original project: factor/offset with about 7
significant digits at run time, IEEE float signals shown as raw values, no CAN FD messages in databases,
multiplexed signals always all shown. - Diagnostics (UDS) settings and J1939 Transmit window data are not saved in the configuration yet (#6).
- Japanese resources are not maintained; the help still has images of the original BUSMASTER.
Problems? Open an issue (English or Italian).
SHA-256 of the zip: 7F8E47EB981D1B255126513F8B13E3392ED6D52957C1221A0172D3276A9BB1E9
BUSMASTER-NG 3.3.0 "Overdrive"
First release of BUSMASTER-NG, the community fork of BUSMASTER 3.2.2.
Not affiliated with ETAS GmbH or Robert Bosch GmbH.
Download and install
Download BUSMASTER-NG_3.3.0_win32.zip below, extract it anywhere and start BUSMASTER.exe. No setup needed.
Requirements:
- Windows 10 or 11 (32 or 64 bit). Windows 7 SP1 should work but has not been tested yet.
- Microsoft Visual C++ 2013 Redistributable (x86) (most PCs already have it).
- The driver of your CAN / LIN interface (PEAK, Vector, Kvaser, ETAS, ...).
What's new
DBC support
- Load DBC (CAN tab, or Ctrl+Shift+M): DBC databases are converted and associated directly, several at once
(rbei-etas#586). - DBC ↔ DBF converters fixed: decimal numbers on Italian / German Windows, large offsets and very small factors
kept exactly, Motorola and 64-bit signals, value descriptions, files that hung or crashed the converter or came
out empty. 26 issues of the original project fixed, partly fixed or explained: see docs/dbc-support.md. - The Format Converter tool is back (it no longer compiled).
User interface
- Sharp display at 125–200% scale (DPI aware): splash, icons, message window, Transmit window.
- Transmit window: resizable with controls that follow it, readable check boxes, negative physical values.
- Dissociate Database: resizable, long paths readable.
- New splash screen, icon and About dialog (BUSMASTER-NG, version 3.3.0).
Reliability
- A missing or damaged driver DLL no longer makes the program hang at start-up: a message says which file
is missing and why. - The trace window shows the right text.
Under the hood
- Built with Visual Studio 2022; a Windows 7 compatible toolset is used for this package.
- Configurations (
.cfx) of BUSMASTER 3.2.x open unchanged.
Known limitations
- The database engine
DBManager.dllis a closed binary of the original project: factor/offset with about 7
significant digits, IEEE float signals shown as raw values, no CAN FD messages in databases (CAN FD frames are
sent and received, shown as raw bytes), multiplexed signals always all shown. - Japanese resources are not maintained; the help still has images of the original BUSMASTER.
Problems? Open an issue (English or Italian).
SHA-256 of the zip: C6CDCD7DAB3043559D823770D965AA9F1BD30C97E1F5936E82A371189F467B4A