Added

  • Automation blueprints in blueprints/automation/curing_chamber/:
    phase / program notifications, cut power on sensor fault, care and weigh-in
    reminder forwarding. Import URLs are listed in the README.
  • Richer batch comparison. A batch's detail shows the chamber
    temperature / humidity recorded over its life under the drying curve, and
    the History table gains Mean T° and Mean RH columns computed from the
    recorder history of each finished batch (next to the program used).
  • Ambient history in the panel. The Chamber view gets a Temperature &
    humidity history
    card (24 h / 7 d / 30 d) drawn from the recorder history
    of the source sensors (and the core probe), with the current targets as
    dashed lines. Websocket state carries the source entity ids in sources.
  • Automatic housekeeping. New Batches & housekeeping options step:
    auto-archive completed batches after N days and delete photos of
    archived batches after N days
    (both 0 = off by default), applied hourly.
    Batches now record completed_at / archived_at; auto-archiving fires a
    batch_archived bus event.
  • Journal on the Lovelace card. Batch summaries carry last_event
    (kind, timestamp, note); the card shows the last journal entry per batch
    and a one-tap Turned button recording it.
  • Batch import. export_batch (service and batch/export websocket)
    takes include_photos to embed the weigh-in photos as photo_data; the new
    import_batch service and batch/import websocket recreate a batch from
    that record (weigh-ins, journal, photos), with a fresh id unless
    overwrite. The panel's Export JSON now embeds the photos and the
    batch list gets an Import a batch button.
  • Program care reminders. A program may carry reminders
    (kind, every_hours, optional note and phases): while it runs, a
    notification suggests that journal entry at the given interval (wall clock,
    not while paused; a phase-scoped reminder counts from the phase start), with
    a reminder bus event carrying the active batches concerned. The panel
    editor has a Care reminders section, the program card shows the next
    reminder, and the Current phase sensor exposes it in next_reminder.
    Cheese presets turn (and wash) the products every day or two.
  • Weigh-in reminder. New Weigh-in reminder after N days option in the
    notifications step (default 7 days, 0 disables): an active batch with no
    weigh-in for that long gets a persistent notification (and the configured
    notify services) once per interval, a weigh_in_due bus event, a
    weigh_in_due flag in its summary (and the list in the Active batches
    sensor attributes) and a badge on its panel card. Recording a weigh-in
    clears it.
  • Ineffective-actuator detection. An actuator that runs continuously for
    longer than the new Ineffective-actuator detection delay option (default
    60 min, 0 disables) without moving its quantity by at least 0.3 °C / 2 %RH
    raises a warning (actuator_ineffective_<cool|heat|humidify|dehumidify>)
    with a targeted hint (compressor, iced evaporator, empty tank…), cleared as
    soon as the quantity moves. New diagnostic binary sensor Actuator
    ineffective
    listing the actuators concerned.

What's Changed

  • Reminders, ineffective-actuator detection, history charts, batch import, housekeeping, blueprints (0.7.0) by @ttiot in #12

Full Changelog: v0.6.0...v0.7.0