Repository navigation
v0.7.0
Added
- Automation blueprints in
blueprints/automation/curing_chamber/:
phase / program notifications, cut power on sensor fault, care and weigh-in
reminder forwarding. Import URLs are listed in the README. - Richer batch comparison. A batch's detail shows the chamber
temperature / humidity recorded over its life under the drying curve, and
the History table gains Mean T° and Mean RH columns computed from the
recorder history of each finished batch (next to the program used). - Ambient history in the panel. The Chamber view gets a Temperature &
humidity history card (24 h / 7 d / 30 d) drawn from the recorder history
of the source sensors (and the core probe), with the current targets as
dashed lines. Websocketstatecarries the source entity ids insources. - Automatic housekeeping. New Batches & housekeeping options step:
auto-archive completed batches after N days and delete photos of
archived batches after N days (both 0 = off by default), applied hourly.
Batches now recordcompleted_at/archived_at; auto-archiving fires a
batch_archivedbus event. - Journal on the Lovelace card. Batch summaries carry
last_event
(kind, timestamp, note); the card shows the last journal entry per batch
and a one-tap Turned button recording it. - Batch import.
export_batch(service andbatch/exportwebsocket)
takesinclude_photosto embed the weigh-in photos asphoto_data; the new
import_batchservice andbatch/importwebsocket recreate a batch from
that record (weigh-ins, journal, photos), with a fresh id unless
overwrite. The panel's Export JSON now embeds the photos and the
batch list gets an Import a batch button. - Program care reminders. A program may carry
reminders
(kind,every_hours, optionalnoteandphases): while it runs, a
notification suggests that journal entry at the given interval (wall clock,
not while paused; a phase-scoped reminder counts from the phase start), with
areminderbus event carrying the active batches concerned. The panel
editor has a Care reminders section, the program card shows the next
reminder, and the Current phase sensor exposes it innext_reminder.
Cheese presets turn (and wash) the products every day or two. - Weigh-in reminder. New Weigh-in reminder after N days option in the
notifications step (default 7 days, 0 disables): an active batch with no
weigh-in for that long gets a persistent notification (and the configured
notify services) once per interval, aweigh_in_duebus event, a
weigh_in_dueflag in its summary (and the list in the Active batches
sensor attributes) and a badge on its panel card. Recording a weigh-in
clears it. - Ineffective-actuator detection. An actuator that runs continuously for
longer than the new Ineffective-actuator detection delay option (default
60 min, 0 disables) without moving its quantity by at least 0.3 °C / 2 %RH
raises a warning (actuator_ineffective_<cool|heat|humidify|dehumidify>)
with a targeted hint (compressor, iced evaporator, empty tank…), cleared as
soon as the quantity moves. New diagnostic binary sensor Actuator
ineffective listing the actuators concerned.
What's Changed
- Reminders, ineffective-actuator detection, history charts, batch import, housekeeping, blueprints (0.7.0) by @ttiot in #12
Full Changelog: v0.6.0...v0.7.0