WayriCAD 4.8.6: One-click thermal workflow and solver reliability
WayriCAD 4.8.6
QuickTherm reliability
-
Run automatically includes valid known power when no sources are selected.
Explicit selections are retained; unknown source watts are never invented. -
Compatible ideal-temperature fixture contacts sharing a mesh cell no longer
prevent a solve. Shared heat flow is counted once; individual shares remain
unknown. Conflicting temperatures are still rejected. -
Built-in layered thermal kernels use diagonally equilibrated sparse solves,
bounded iterative refinement and componentwise backward-error checks. -
The shared electrothermal kernel now uses bounded radiation Newton steps,
matching standalone QuickTherm's protection against first-step overshoot. -
Failed jobs clear the misleading running status in the results panel.
-
Optional CalculiX runs can provision the pinned official Windows x64 2.23
static solver into a private cache, with archive/binary checksums, an actual
launch check, cross-process locking, atomic activation and provenance. -
Existing explicit solver paths and PATH discovery retain priority. CLI
--no-solver-installsupports offline workflows. Non-Windows platforms retain
explicit OS-installed solver selection.
Scope
No new general-purpose FEM backend, CFD, physical contact inference, or measured
temperature accuracy is claimed. Shared-cell fixture flux is a mesh-level
reaction, not independently resolved physical contact flux. Existing CalculiX
geometry restrictions remain. No public binaries from older versions are replaced.
Validation evidence is recorded separately before publication.