91 changes: 91 additions & 0 deletions zhaquirks/centralite/3300S.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,91 @@
from zigpy.profiles import PROFILES, zha
from zigpy.zcl.clusters.general import Basic, Identify,\
PollControl, Ota, BinaryInput
from zigpy.zcl.clusters.security import IasZone
from quirks.centralite import PowerConfigurationCluster
from zigpy.zcl.clusters.measurement import TemperatureMeasurement
from zigpy.quirks import CustomDevice


DIAGNOSTICS_CLUSTER_ID = 0x0B05 # decimal = 2821
MANUFACTURER_SPECIFIC_PROFILE_ID = 0xC2DF # decimal = 49887


class CentraLite3300S(CustomDevice):

def __init__(self, *args, **kwargs):
super().__init__(*args, **kwargs)

signature = {
# <SimpleDescriptor endpoint=1 profile=260 device_type=1026
# device_version=0
# input_clusters=[0, 1, 3, 1026, 1280, 32, 2821]
# output_clusters=[25]>
1: {
'profile_id': zha.PROFILE_ID,
'device_type': zha.DeviceType.IAS_ZONE,
'input_clusters': [
Basic.cluster_id,
PowerConfigurationCluster.cluster_id,
Identify.cluster_id,
PollControl.cluster_id,
TemperatureMeasurement.cluster_id,
IasZone.cluster_id,
DIAGNOSTICS_CLUSTER_ID
],
'output_clusters': [
Ota.cluster_id
],
},
# <SimpleDescriptor endpoint=2 profile=49887 device_type=12
# device_version=0
# input_clusters=[0, 1, 3, 15, 2821]
# output_clusters=[3]>
2: {
'profile_id': MANUFACTURER_SPECIFIC_PROFILE_ID,
'device_type': zha.DeviceType.SIMPLE_SENSOR,
'input_clusters': [
Basic.cluster_id,
PowerConfigurationCluster.cluster_id,
Identify.cluster_id,
BinaryInput.cluster_id,
DIAGNOSTICS_CLUSTER_ID
],
'output_clusters': [
Identify.cluster_id
],
},
}

replacement = {
'endpoints': {
1: {
'manufacturer': 'CentraLite',
'model': '3300-S',
'input_clusters': [
Basic.cluster_id,
PowerConfigurationCluster,
Identify.cluster_id,
PollControl.cluster_id,
TemperatureMeasurement.cluster_id,
IasZone.cluster_id,
DIAGNOSTICS_CLUSTER_ID
],
'output_clusters': [
Ota.cluster_id
],
},
2: {
'manufacturer': 'CentraLite',
'model': '3300-S',
'input_clusters': [
Basic.cluster_id,
Identify.cluster_id,
DIAGNOSTICS_CLUSTER_ID,
],
'output_clusters': [
Identify.cluster_id
],
}
},
}