Continuation of the 5KES megadthread at DIYSolarForum
Specifically, the code implementation of design #216
| Conduit | Type | Description |
|---|---|---|
| 1 | 3/4" EMT or LT | Growatt AC Input From Service Panel |
| 2 | 3/4" EMT or LT | Growatt AC Output to Inverter Disconnect Service Panel |
| 3 | 3/4" EMT or LT | Inverter Disconnect to 240V Loads Panel (Optional) |
| 4 | 3/4" EMT or LT | Inverter Disconnect to Logic Switching Enclosure |
| 5 | 3/4" EMT or 1/2" LT | Switching Logic Enclosure to 120/240V Loads Panel |
| 6 | 1/2" EMT or LT | Switching Logic Enclosure to Autotransformer |
| 7 | 1/2" EMT or LT | NodeMCU GPIO Interrupt (3VDC Logic Level) ATS Dry Contact |
| Conduit | Conductor | Gauge | Type |
|---|---|---|---|
| 1 | 1 | 6 | THHN 90°C |
| 1 | 2 | 6 | THHN 90°C |
| 1 | 3 | 10 | THHN 90°C |
| 1 | 4 | 6 | THHN 90°C |
| 1 | 5 | 6 | THHN 90°C |
| 2 | 1 | 6 | THHN 90°C |
| 2 | 2 | 6 | THHN 90°C |
| 2 | 3 | 10 | THHN 90°C |
| 2 | 4 | 6 | THHN 90°C |
| 2 | 5 | 6 | THHN 90°C |
| 3 | 1 | 6 | THHN 90°C |
| 3 | 2 | 6 | THHN 90°C |
| 3 | 3 | 6 | THHN 90°C |
| 4 | 1 | 10 | THHN 90°C |
| 4 | 2 | 10 | THHN 90°C |
| 4 | 3 | 10 | THHN 90°C |
| 4 | 4 | 10 | THHN 90°C |
| 4 | 5 | 10 | THHN 90°C |
| 4 | 6 | 10 | THHN 90°C |
| 5 | 1 | 10 | THHN 90°C |
| 5 | 2 | 10 | THHN 90°C |
| 5 | 3 | 10 | THHN 90°C |
| 5 | 4 | 10 | THHN 90°C |
| 6 | 1 | 10 | THHN 90°C |
| 6 | 2 | 10 | THHN 90°C |
| 6 | 3 | 10 | THHN 90°C |
| 6 | 4 | 10 | THHN 90°C |
| 6 | 5 | 22 | K-Type Thermocouple Wire |
| 6 | 6 | 22 | K-Type Thermocouple Wire |
| 7 | 1 | 28 | Automotive Primary Wire |
| 7 | 2 | 28 | Automotive Primary Wire |
TBD