Exploited CVE-2023-35835.
This device exposes status and telemetry report over the network. The wrapper fetches device status, including current (A) and voltage (V) readings.
The mapping of data fields from the Solax API response.
The data is extracted from a JSON response which contains a Data list (referred to as raw in the script), an Information list, and some root-level properties.
| Index | Description | Notes |
|---|---|---|
| 0 | Grid Voltage | Scaled by 0.1, in Volts (V) |
| 1 | PV1 Current | Scaled by 0.1, in Amperes (A) |
| 2 | Grid Frequency | Scaled by 0.01, in Hertz (Hz) |
| 3 | PV1 Input Power | In Watts (W) |
| 3 | Inverter Active Power | In Watts (W) |
| 4 | PV1 Voltage | Scaled by 0.1, in Volts (V) |
| 8 | Grid Current | Scaled by 0.1, in Amperes (A) |
| 11 | Grid Power | In Watts (W) |
| 13 | Total Solar Power | In Watts (W) |
| 19 | Total Yield | Scaled by 0.1, in kilowatt-hours (kWh) |
| 21 | Daily Yield | Scaled by 0.1, in kilowatt-hours (kWh) |
| 23 | Inverter Temperature | In Celsius (°C) |
| Index | Description |
|---|---|
| 2 | Device Model/Info |
| Key | Description |
|---|---|
sn |
Device Serial Number |