  • Document the Cable Report's aerial cable sheet (ARES_CableReport_Aerial_Nature_Property) Aerial cables, told apart by their own Nature property, go on a sheet of their own and are never measured against a zone; Nature is read on the cable first, then its group. EN and FR pages, plus both configuration variable references. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01M1GZGQwwNEL2mDxhYhnSuM

    @Asketyll Asketyll committed Sep 14, 2026
  • Cable Report: default crossing factor 3.5 A factor of 2 is one trench width and only excludes a perpendicular crossing; oblique ones measure more and survived it. Explains the arithmetic rather than just stating the number. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DxeZtStK38ZCiwBCptdcTG

    @Asketyll Asketyll committed Sep 3, 2026
  • Cable Report: the crossing threshold is a factor on the trench width ARES_CableReport_Min_Length (absolute, 1 m) becomes ARES_CableReport_Cross_Factor (default 2), multiplying ARES_Outline_Distance so the threshold follows the trench. Says plainly that the default equals one trench width - a perpendicular crossing's own value - and that an oblique crossing exceeds it and still counts. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DxeZtStK38ZCiwBCptdcTG

    @Asketyll Asketyll committed Sep 3, 2026
  • Cable Report: a crossing is not a shared trench Two cables that cross leave each other's cable inside their trench for about its width, which the report used to read as a shared trench of half a metre. Adds ARES_CableReport_Min_Length (1 m) to the four variable tables and says, where shared trenches are explained, why a crossing does not qualify. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DxeZtStK38ZCiwBCptdcTG

    @Asketyll Asketyll committed Sep 3, 2026
  • docs: shared trenches in the Cable Report pages (EN/FR) Shared trenches now read as their own pivot column ("CH2C (2)") next to the ordinary one, keyed on the group of cables: two TA1 zones shared by different pairs give "TA1 (2)" and "TA1 (2) #2". Updated the example tables, the soil-type column description, and the shared-trench section on both pages. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DxeZtStK38ZCiwBCptdcTG

    @Asketyll Asketyll committed Sep 2, 2026
  • docs: add Cable Report page (EN/FR), its variables, and RecalculateSelection - New pages Cable-Report / Rapport-de-Cables (key-ins, behaviour, the 9 ARES_CableReport_* variables); linked from _Sidebar, Home / Accueil, Configuration-Variables / Variables-de-Configuration. - System-and-Config / Systeme-et-Config: new RecalculateSelection key-in. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01DxeZtStK38ZCiwBCptdcTG

    @Asketyll Asketyll committed Sep 1, 2026