Motor Access & Switch Scanning Guide

Every individual has unique physical and motor abilities. BridgeAAC includes an extensive suite of motor access tools — from touch timing filters for tremors or resting hands, to pointer dwell for eye-gaze tracking, to 1-switch and 2-switch scanning.

Tip

Universal Switch & Eye-Gaze Support: BridgeAAC works natively with standard Bluetooth accessibility switches (Ablenet Blue2, Pretorian) and eye-tracking systems without requiring proprietary manufacturer bridges.


1. Touch Timing Filters

In Settings → Access, you can configure filters to adapt touch behavior to the user’s physical movement patterns:

Hold Duration (0 – 1200 ms)

  • Clinical Purpose: Prevents accidental touches caused by involuntary spasms, hand tremors, or swiping movements across the screen.
  • How it works: The user must maintain finger contact on a cell for the specified duration before the button activates. A subtle visual border animation indicates the touch is registering.
  • Recommended starting setting: 250 ms for mild tremors, 500 ms for pronounced athetoid movements.

Ignore Repeat / Debounce (0 – 2000 ms)

  • Clinical Purpose: Prevents rapid repeated activations if a user taps a button multiple times quickly due to poor motor control or perseveration.
  • How it works: After a button is tapped, BridgeAAC ignores subsequent presses on that same button until the debounce timer expires.
  • Recommended starting setting: 400 ms.

Activate on Release

  • Clinical Purpose: Essential for communicators who rest their hand or arm on the screen to stabilize their movement, then slide their finger to the intended cell and release.
  • How it works: The button does not trigger when touched; it only triggers at the exact moment the finger is lifted off the screen within the target cell’s boundaries.

2. Pointer Dwell (Eye-Gaze & Head-Tracking)

For communicators who use eye-tracking hardware (such as Tobii Dynavox, Skyle for iPad, or Irisbond) or head-tracking mice (such as GlassOuse or Smyle Mouse):

Configuring Pointer Dwell

  1. Open Settings → Access.
  2. Locate Pointer Dwell.
  3. Set the dwell duration (0 ms = Off, 300 – 2500 ms = Active).
  4. When enabled, resting the mouse cursor or eye-gaze tracker over any button displays a circular SVG countdown ring around the pointer.
  5. When the countdown completes, the button activates automatically without requiring a physical click or tap.
   [ Button ] ──> Pointer hovers over button
   [ Button ⏳ ] ──> Circular dwell timer animates (e.g. 800ms)
   [ Button ✨ ] ──> Dwell completes: Word is spoken and added

3. Switch Scanning

Switch scanning allows individuals who cannot reliably touch a screen or use a pointer to communicate using one or two physical switches (such as jelly bean buttons, sip-and-puff switches, or head-tilt switches).

Scan Methods

Mode Number of Switches How It Works Best For
1-Switch Auto-Scan 1 The app automatically cycles the yellow highlight through rows or buttons at a set speed. The user presses their single switch when the desired item is highlighted. Users with limited endurance who can execute one reliable movement.
2-Switch Step-Scan 2 Switch 1 ("Step") manually moves the highlight to the next row or button. Switch 2 ("Select") activates the highlighted item. Users with good cognitive stamina who prefer full control over pacing.

Scan Patterns

  1. Row-then-Column (Default):
    • The scanner first highlights entire rows from top to bottom.
    • Activating on a row causes the scanner to step across the individual buttons within that selected row.
    • Activating on a button speaks/inserts that item.
  2. Column-then-Row:
    • The scanner first highlights vertical columns from left to right, then steps through the cells within the chosen column.
  3. Linear:
    • The scanner highlights buttons one-by-one sequentially from top-left to bottom-right. Ideal for small grids (e.g., 2x2 or 3x3).

Scan Configuration Settings

  • Scan Speed (0.4s – 5.0s): Controls how long the highlight pauses on each item in Auto-Scan mode. (Recommended starting point: 1.5s).
  • Max Loops (1 – 5): How many times the scanner will cycle through the board before automatically pausing if no switch input is detected.
  • Audio Prompts (Auditory Scanning):
    • If enabled, BridgeAAC speaks the name of each row or button through the user's private headphones before they select it. Ideal for communicators with visual impairments or cortical visual impairment (CVI).

4. Hardware Switch Setup & Key Mapping

BridgeAAC switch scanning works with any Bluetooth, USB, or accessibility switch interface that produces keyboard keystrokes:

Hardware Interface Connection Type Switch 1 Default Key Switch 2 Default Key
Ablenet Blue2 Bluetooth Space Enter (~1 / ~3)
Pretorian Applicator Bluetooth Space Enter
Crick USB Switch Box USB Space Enter
Xbox Adaptive Controller USB / Bluetooth Gamepad Button A Gamepad Button B
Standard USB Keyboard USB Space (Select) Enter (Next)

Testing Your Switch Setup:

  1. Connect your switch interface to your iPad, tablet, or PC via Bluetooth or USB.
  2. In BridgeAAC, open Settings → Access.
  3. Toggle Switch Scanning to ON.
  4. Tap Test Switch Input: Press your physical switch to verify that BridgeAAC receives the event and illuminates the on-screen switch test indicator.