Skip to content

fix generators only outputting once per second#214

Merged
TechLord22 merged 2 commits intomasterfrom
generator-fix
Nov 5, 2021
Merged

fix generators only outputting once per second#214
TechLord22 merged 2 commits intomasterfrom
generator-fix

Conversation

@TechLord22
Copy link
Copy Markdown
Member

@TechLord22 TechLord22 commented Nov 5, 2021

Generators would only output energy once per second due to the isObstructed checking. This PR fixes it. Another issue encountered was some generators not starting and consuming inputs due to there being no notifiable inputs, this was also fixed by making generators use notifiable tanks.

@TechLord22 TechLord22 merged commit 50d798a into master Nov 5, 2021
@TechLord22 TechLord22 deleted the generator-fix branch November 5, 2021 18:53