Skip to content

Conversation

@subagonsouth
Copy link
Contributor

Revert how statistical uncertainty is computed until further direction from Hi IT

Change Summary

Overview

This is a quick fix to get the statistical uncertainty looking more correct. I am waiting on direction from the Hi IT to clarify in the algorithm document how this should really be calculated when combining calibration products.

Updated Files

  • imap_processing/hi/hi_l2.py
    • For now, just add the individual calibration product statistical uncertainties in quadrature
  • imap_processing/tests/hi/test_hi_l2.py
    • Fix tests to expect uncertainties added in quadrature

Closes: #2252

@subagonsouth subagonsouth self-assigned this Oct 7, 2025
@subagonsouth subagonsouth added this to IMAP Oct 7, 2025
@subagonsouth subagonsouth merged commit 10504d6 into IMAP-Science-Operations-Center:dev Oct 7, 2025
14 checks passed
@subagonsouth subagonsouth deleted the 2252-bug---hi-l2---incorrect-statistical-uncertainty branch October 7, 2025 15:40
@github-project-automation github-project-automation bot moved this to Done in IMAP Oct 7, 2025
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

Status: Done

Development

Successfully merging this pull request may close these issues.

BUG - Hi L2 - Incorrect statistical uncertainty