33 changes: 33 additions & 0 deletions plots/psychrometric-basic/specification.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,33 @@
# psychrometric-basic: Psychrometric Chart for HVAC

## Description

A psychrometric chart plots dry-bulb temperature against humidity ratio, overlaid with curves for relative humidity, wet-bulb temperature, enthalpy, and specific volume. It is the fundamental tool for HVAC system design and air conditioning process analysis. The chart reveals the thermodynamic properties of moist air at a glance, enabling engineers to trace heating, cooling, humidification, and dehumidification processes as paths on the diagram.

## Applications

- HVAC engineering: designing and analyzing air conditioning systems by tracing process paths (heating, cooling, mixing) on the chart
- Building science: evaluating indoor thermal comfort zones and identifying condensation risks
- Industrial process engineering: optimizing drying operations and clean room environmental control

## Data

- `dry_bulb_temp` (float) - Dry-bulb air temperature in degrees Celsius, x-axis primary variable
- `humidity_ratio` (float) - Mass of water vapor per mass of dry air in g/kg, y-axis primary variable
- `relative_humidity` (float[]) - Constant relative humidity curves from 10% to 100% in 10% increments
- `wet_bulb_temp` (float[]) - Diagonal lines of constant wet-bulb temperature
- `enthalpy` (float[]) - Oblique lines of constant enthalpy in kJ/kg
- `specific_volume` (float[]) - Lines of constant specific volume in m3/kg
- Size: derived from psychrometric equations over a dry-bulb range of -10 to 50 degrees Celsius
- Example: standard atmosphere (101.325 kPa) psychrometric properties computed from ASHRAE formulas

## Notes

- The saturation curve (100% RH) forms the upper boundary of the chart and should be visually prominent
- Relative humidity curves (10%-100%) should be drawn as smooth curves between the saturation line and x-axis
- Wet-bulb and enthalpy lines run diagonally from upper-left to lower-right
- Specific volume lines run at a slightly different diagonal angle
- Include at least one example HVAC process path (e.g., cooling and dehumidification) shown as an arrow or highlighted line segment between two state points
- A comfort zone region (approximately 20-26 C, 30-60% RH) should be highlighted as a shaded rectangle or polygon
- All property lines should be labeled directly on the chart, not just in a legend
- Use standard sea-level atmospheric pressure (101.325 kPa) for calculations
28 changes: 28 additions & 0 deletions plots/psychrometric-basic/specification.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,28 @@
# Specification-level metadata for psychrometric-basic
# Auto-synced to PostgreSQL on push to main

spec_id: psychrometric-basic
title: Psychrometric Chart for HVAC

# Specification tracking
created: "2026-03-06T19:54:00Z"
updated: null
issue: 4583
suggested: MarkusNeusinger

# Classification tags (applies to all library implementations)
# See docs/reference/tagging-system.md for detailed guidelines
tags:
plot_type:
- line
- contour
data_type:
- numeric
- continuous
domain:
- engineering
- energy
features:
- advanced
- annotated
- multi