TRIA3K with a nonsymmetric laminate would solve but produce wrong results. The error message that should have stopped it was checking for QUAD4K instead of TRIA3K. I changed that and deleted the irrelevant message about QUAD4K.

@SteveDoyle2 SteveDoyle2 merged commit f8441e5 into MystranSolver:main Apr 12, 2025