Skip to content

History / PureSignal

Revisions

  • docs(wiki): add PureSignal Feedback Calibration page Bench procedure for setting HW Peak on chains that don't match the per-board defaults — external amp sample taps, inline attenuator pads, non-standard coupler factors. Covers what the Observed bar actually measures (post-IQC TX envelope vs LUT scale, not raw feedback RF), how to use Feedback Level as the ground-truth ADC indicator, when to add a pad vs adjust HW Peak, and a worked example for the ANAN-G2 + RF2K-S -55 dB tap chain that lands at HW Peak 0.655.

    @Kb2uka Kb2uka committed May 16, 2026
  • Add PureSignal wiki page covering the redesigned dashboard UX Walkthrough of both surfaces (transport-bar popover and the SETTINGS → PURESIGNAL dashboard) with screenshots of each section: calibration ring + STATE label, signal flow chips, observed-vs-HW-peak pairing, correction readout, coupler selector (internal for HL2, external for ANAN/Saturn), Auto/Single mode, run/reset, and the timing + hardware panes underneath. Includes a STATE vs CORRECTING explainer for the most common point of confusion: STATE is the calcc inner-loop step (cycles continuously in Auto), CORRECTING is the orthogonal info[14] flag that means predistortion is currently shaping TX. They're independent. Adds per-board notes (HL2 internal coupler default, P2 external coupler wiring, HW peak factory values) and an updated troubleshooting section. The legacy PureSignal-on-Protocol-2 page now redirects to the new page at the top — kept around so older issue / PR links still resolve. The sidebar and Home links point at the new page.

    Brian Keating committed May 3, 2026