Notifications
You must be signed in to change notification settings - Fork 110
OpenWebNet Protocol & WHO Specifications
Welcome to the OpenWebNet Protocol & WHO Specifications Archive. This document serves as the official open-access registry and cross-check inventory of all technical manuals, frame syntax, dimension definitions, and PDF specifications published by BTicino / Legrand for the OpenWebNet protocol across MyHOME systems.
Historically, these technical specifications were distributed through the MyOpen Community portal (myopen-legrandgroup.com / myopen-bticino.it), which is no longer active. To ensure that developers, installers, and community members have permanent access to accurate protocol documentation, we maintain this centralized registry.
- 🏛️ Official Legrand Developer Portal: Legrand Local Interoperability — PDF Documentation
- 📦 Master Document Archive: OWN DOC.zip (GitHub PR #232 Attachment) — Complete 15-document bundle preserved and contributed by @GianlucaCh.
- 🪄 Home Assistant Community Blueprint: MyHome CEN+ Commands Blueprint — Connect physical MyHOME CEN / CEN+ scenario pushbuttons to toggle non-BTicino entities and dim lights.
- 📖 Interactive GitHub Wiki: OpenWebNet Protocol & WHO Specifications
Thanks to community contributions—in particular the comprehensive technical manual archive contributed by @GianlucaCh in PR #232—15 official specifications are now preserved, verified, and cross-checked against live installations!
If you are a certified BTicino / Legrand installer, system integrator, or MyHOME software specialist (such as @xtimmy86x, @lyubomirtraykov, and fellow community professionals), your real-world experience across varied plant configurations and engineering software continues to help us fill the final remaining gaps:
-
Document Versions & Revision Dates:
- Compare your PDF archive against the Master WHO Family Inventory table below.
- Look at the cover page and revision history (e.g. Last date modify, Version number). If your copy is newer than what is listed, please share the version details!
-
Remaining Missing / Legacy Specifications:
-
WHO = 3: Load control legacy central unit (F421) (Seeking newer official PDF than 2006). -
WHO = 6: Dedicated audio door entry call frames (Seeking standalone document beyond WHO 7 / Intro). -
WHO = 9: Auxiliary channels (AUX 1–9) (Seeking newer official PDF than 2006). - (Note:
WHO = 14Actuator Lock is fully reverse-engineered and documented below; Legrand never published a public standalone PDF).
-
-
Software Tooling & Dictionaries (MyHOME_Suite / TiMyHome):
- Command definitions or exported XML dictionaries from Legrand/BTicino configuration software (MyHOME_Suite, TiMyHome, Virtual Configurator, MyHOME_Up).
💡 How to Contribute: You can share filenames, revision dates, technical sheets, or bus monitor traces by opening an issue on the OpenWebNet-HA/MyHOME GitHub repository or commenting directly in PR #232. Every contribution helps ensure open, permanent documentation for the entire MyHOME ecosystem.
The table below catalogs every known OpenWebNet function family (WHO), its official Legrand document title, current known version, archive status, and Home Assistant platform mapping.
- 🟢 Archived & Verified: Official PDF is preserved in our archive with full syntax verified.
- 🟡 Legacy Copy Available / Cross-Check Needed: Legacy documentation or reverse-engineered definitions exist; seeking confirmation of the latest official version.
- 🔴 Needed / Missing: Seeking the official Legrand/BTicino PDF specification.
| WHO | Subsystem / Function | Official Document Title / Filename | Known Version & Date | Status | Home Assistant Entity / Platform | Notes & Supported Hardware |
|---|---|---|---|---|---|---|
| 0 | Scenarios (Basic) |
Open Web Net Language (Scenarios) / WHO_0.pdf
|
v2.0.0 (2010-10-01) | 🟢 |
event, automations |
32 standard scenarios. Legrand 03551, 88301; BTicino F420, IR interface 3456. Contributed by GianlucaCh. |
| 1 | Lighting (Illuminazione) |
Who = 1 LIGHTING / WHO_1.pdf
|
v1.1.0 (2014-11-17) | 🟢 | light |
ON, OFF, Dimming (1-100%, 10 levels, steps), Blink, Timer, Speed of transition. Extended lighting & DALI dimensions (tunable white / RGBW via F429/F429G). Contributed by GianlucaCh. |
| 2 | Automation (Automazione) |
Messages - Automation / WHO_2.pdf
|
v1.0.0 (2015-11-12) | 🟢 | cover |
Roller shutters, venetian blinds, motorized curtains, gates. Standard UP/DOWN/STOP and advanced absolute positioning percentage (0-100%, Legrand 67557). Contributed by GianlucaCh. |
| 3 | Load Control (Legacy) |
OpenWebNet_Community_3_LoadControl / WHO_3.pdf
|
v1.0.0 (2006) | 🟡 |
switch, sensor
|
Priority-based load disconnection central unit (F421). Inhibit/force actuators. |
| 4 | Thermoregulation (Termoregolazione) |
Open Web Net Language - Heating adjustment / WHO_4 2.pdf
|
v2.0.0 (2013-11-27) | 🟢 |
climate, sensor
|
4-zone / 99-zone central units (3550), standalone thermostats (L/N/NT4691), external probe sensors (3475). Added dimension 22 (offset) and dimension 11 (fancoil 3-speed). Contributed by GianlucaCh. |
| 5 | Burglar Alarm (Antifurto) |
MyHome Burglar Alarm / WHO_5.pdf
|
(2008-02-13) | 🟢 | alarm_control_panel |
Central units (3485, 3486), partition arming/disarming, panic alarms, gas/water technical alarms, sensor zone status. Authored by Lorenzo Pini. Contributed by GianlucaCh. |
| 6 | Door Entry Call & Lock |
OpenWebNet_Community_DoorEntry / WHO_6.pdf
|
v1.0.0 (2006) | 🟡 |
lock, switch, event
|
Audio door entry calls, door lock release (*6*10*<WHERE>##), staircase light, camera switching, incoming call chimes. |
| 7 | Video Door Entry / Multimedia |
Open Web Net WHO=7 / WHO_7.pdf
|
v1.0.1 (2011-12-01) | 🟢 | camera |
Video session establishment, camera selection, video stream routing over IP for Video Server F453AV. Contributed by GianlucaCh. |
| 9 | Auxiliary (Comandi Ausiliari) |
OpenWebNet_Community_Auxiliary / WHO_9.pdf
|
v1.0.0 (2006) | 🟡 | switch |
Auxiliary channels (AUX 1 to AUX 9) for triggering remote relays, annunciators, or inter-system signals without occupying lighting addresses. |
| 13 | Gateway Management |
OpenWebNet_Community_2_device_v1_0_0_EN / WHO_13.pdf
|
v1.0.0 (2006-06-13) | 🟢 | Core diagnostics | Date/time synchronization (*#13**0*...), firmware version query, IP configuration, MAC address, uptime, reboot command. Contributed by GianlucaCh. |
| 14 | Actuators Lock (Light & Shutters) |
Light & Shutter Actuators Lock (No Public PDF)
|
v1.0.0 (2008) | 🟢 | Core diagnostics, button, lock
|
Physical endpoint lock/unlock. Lock (*14*0*<WHERE>##), Unlock (*14*1*<WHERE>##), Status query (*#14*<WHERE>##). Inverts/locks physical wall button input. Legrand never distributed a public standalone PDF (internal diagnostic spec). |
| 15 | CEN Scenario Control (Scheduler) |
CEN Frames for Scenario Scheduler / WHO_15-25.pdf
|
v1.0.0 (2010-10-01) | 🟢 |
event, device triggers |
Pushbutton scenario events for Scenario Scheduler (MH200, MH200N, Legrand 03565): Virtual/physical pressure, short release, extended pressure, release after extended pressure. Contributed by GianlucaCh. |
| 16 | Sound Distribution (Zone/Amp Control) |
OpenWebNet_Community_4_soundsystem / WHO_16.pdf
|
v1.0.1 (2011-11-24) | 🟢 | media_player |
Multi-room audio matrix & zone control: Amplifier ON/OFF, volume control (step & %), audio input source selection (RDS tuner, RCA/aux, USB, Bluetooth), equalizer (bass, treble, balance), station presets (F441, F441M, F450, 3487). |
| 17 | Scenario Programmer (Scenes) |
Who = 17 SCENES / WHO_17.pdf
|
v1.0.0 (2015-04-09) | 🟢 |
switch, event
|
MH200 / MH200N / MH202 scenario programmer integration, enable/disable automated schedules, trigger macro executions. Contributed by GianlucaCh. |
| 18 | Energy Management Functions |
Energy Management Functions / WHO_18 1.pdf
|
v1.0.0 (2011-07-15) | 🟢 | sensor |
Electricity, water, and gas pulse meters. Instantaneous power (W), cumulative active energy (kWh), current (mA), voltage (V), power factor, tariff periods (F80/x, F520, F521, F522, F523, 3522). Contributed by GianlucaCh. |
| 22 | Sound Diffusion (Source & Speaker) |
Who = 22 Sound Diffusion / WHO_22.pdf
|
v1.1.0 (2014-06-12) | 🟢 | media_player |
Sound source navigation & speaker control: Radio FM frequency step up/down, station navigation, track skipping (next/previous track), RDS text display control (*22*31...), station presets, and speaker volume. Contributed by GianlucaCh. |
| 24 | Lighting Management (Gestione Luci) |
Who_24_eng_PUBBLIC.doc / WHO_24.pdf
|
v1.0.0 (2012-04-06) | 🟢 |
light, sensor
|
Legrand / BTicino Lighting Management System (BMNE500 / 002645 room controller, BMview, Lighting Console). Zone addressing (1000+zone), dimensions 1–12 (switch-on level %, max lux, maintained level lux, auto switch on/off, switch on/off delay, delay timer, standby timer/value, off value, slave offset GAP), dimension 17 (state: Auto/Manual/Stop), dimension 18 (centralised lux sensor reporting). Profile frames (*24*1#Profile_ID*WHERE##) and slave offset (*24*2#[0-1]*WHERE##). Contributed by GianlucaCh. |
| 25 (CEN+) | CEN+ Scenario Control (Scheduler) |
CEN Frames for Scenario Scheduler / WHO_15-25.pdf
|
v1.0.0 (2010-10-01) | 🟢 |
event, device triggers |
Extended CEN protocol with up to 256 buttons/scenarios for MH200/MH200N/03565: Short pressure (<0.5s), start of extended pressure (>=0.5s), extended pressure holding, release after extended pressure. Contributed by GianlucaCh. |
| 25 (Contacts) | Dry Contact & IR State Functions |
DRY CONTACT AND IR STATE FUNCTIONS / WHO_25.pdf
|
v1.0.0 (2010-11-04) | 🟢 | binary_sensor |
Dry contact interfaces & IR sensor state: State ON / IR detection (WHAT=31), State OFF / IR not detected (WHAT=32), event-driven (PARAM=1) or poll request (PARAM=0). BTicino 3477, F428, 3480, F482, IR 4610/4611/4640; Legrand 573996, 03553, 067513, etc. Contributed by GianlucaCh. |
| HMAC | Gateway Security & Authentication |
Hmac Specification / Hmac.pdf
|
v1.1.0 (2016-08-05) | 🟢 | Core transport | Cryptographic challenge-response HMAC-SHA256 authentication replacing legacy OPEN numeric password authentication for modern gateways (MyHomeServer1, F455, F461). Contributed by GianlucaCh. |
| INTRO | OpenWebNet System Architecture |
INTRODUCTION Examples of Integration / OWN INTRO.pdf
|
(2012-10-03) | 🟢 | Core protocol | Foundational architecture manual by BTicino detailing frame delimiters, session separation (Command vs Event/Status), ACK/NACK signaling, and system integration patterns. Contributed by GianlucaCh. |
| 1000 | Automation Group Commands | Embedded in WHO 2 | — | 🟡 | cover |
Area and General group broadcast commands for automation. |
| 1001 | Lighting Group Commands | Embedded in WHO 1 | — | 🟡 | light |
Area and General group broadcast commands for lighting. |
| 1004 | Temperature Group Commands | Embedded in WHO 4 | — | 🟡 | climate |
Zone group commands for thermoregulation. |
A common source of confusion in the OpenWebNet ecosystem stems from the shared WHO = 25 code. As highlighted by @GianlucaCh, these are two completely distinct official specifications:
-
Scenario Scheduler CEN / CEN+ (
WHO_15-25.pdf):- Covered Devices: Scenario Programmers and Controllers (MH200, MH200N, MH201, Legrand 03565).
- Protocol Nature: Pushbutton scenario trigger events.
-
Syntax:
*25*<WHAT>*<WHERE>##whereWHATencodes:-
21: Short pressure (< 0.5 seconds). -
22: Start of extended pressure (>= 0.5 seconds). -
23: Extended pressure holding. -
24: Release after extended pressure.
-
-
Addressing (
WHERE): Scenario address up to 256 buttons/scenarios ([1-256]).
-
Dry Contact Interfaces & IR Sensors (
WHO_25.pdf):- Covered Devices: Physical interface modules (BTicino 3477, F428, 3480, F482, IR 4610/4611/4640; Legrand 573996, 03553, 067513, etc.).
- Protocol Nature: Hardware state telemetry for magnetic window/door reed switches, technical contacts, and passive infrared motion detectors.
-
Syntax:
*25*<WHAT>*<WHERE>##or dimension frames whereWHATindicates:-
31: Contact ON / IR detection (closed contact or motion detected). -
32: Contact OFF / IR not detected (opened contact or motion cleared).
-
-
Parameter (
PARAM):-
PARAM = 0: State response upon polling request. -
PARAM = 1: State response upon real-time system event.
-
-
Home Assistant Entity: Exposed as
binary_sensor(e.g. window opened/closed, PIR motion).
The sound subsystem is split across two dedicated OpenWebNet WHO families:
-
WHO = 16 (Sound Distribution — Zone & Matrix Management):
- Controls physical audio amplifiers and source matrix units (F441, F441M, F450, 3487).
- Functions include: Zone power (ON/OFF), volume attenuation (0–31 scale / percentages), audio input channel routing (IN 1 to IN 4), tone equalizers (bass, treble, balance), and master room follow-me.
- Mapped to Home Assistant
media_playerentities.
-
WHO = 22 (Sound Diffusion — Source & Speaker Navigation):
- Controls the audio source devices themselves (FM tuner, CD player, multimedia source) and individual speaker units.
- Functions include:
- FM tuner frequency step up/down (
WHAT = 5/WHAT = 6). - Station preset navigation (
WHAT = 9next /WHAT = 10previous). - Track navigation (
WHAT = 11next track /WHAT = 12previous track). - RDS text string display streaming (
WHAT = 31start /WHAT = 32stop). - Direct frequency tuning and preset memorization (
WHAT = 33). - Speaker volume adjustment (
WHAT = 3increase /WHAT = 4decrease).
- FM tuner frequency step up/down (
BTicino and Legrand never distributed a standalone WHO_14.pdf in their public developer distributions, retaining it as an internal/installer diagnostic function. However, the protocol grammar is fully reverse-engineered and verified across live systems:
- Protocol Function: Inhibits physical wall buttons (rocker switches, CEN pushbuttons) and remote actuation for safety, maintenance, or child locking on lighting and cover/shutter actuators (F411, F411U2, F418, LN4672M2).
-
Lock Actuator (Disable Controls):
*14*0*<WHERE>##- Freezes the relay in its current position and disables physical switch inputs.
-
Unlock Actuator (Enable Controls):
*14*1*<WHERE>##- Restores normal operation and re-enables physical wall buttons and bus commands.
-
Status Query:
*#14*<WHERE>##- Returns
*14*0*<WHERE>##(Locked) or*14*1*<WHERE>##(Unlocked).
- Returns
-
Home Assistant Integration: Represented via configuration button entities (
DisableCommandButtonEntityandEnableCommandButtonEntity) under each actuator device. -
Gateway Support: Supported on modern gateways (F454, MyHomeServer1). Older gateways (e.g. early F455 firmware) return NACK (
*#*0##).
One of the most powerful capabilities of physical MyHOME installations is using existing BTicino wall pushbuttons and dry contact modules (such as the 3477 interface) to trigger automations across modern smart home ecosystems.
A highly recommended blueprint developed by the Home Assistant community (by gST84) is available on the Home Assistant Community Forum:
👉 MyHome - CEN+ commands Blueprint (Community Forum)
👉 Raw Blueprint Source YAML (GitHub)
- Control Non-BTicino Devices: Use your native BTicino wall switches to switch or toggle non-BTicino smart devices (Philips Hue, Zigbee, Z-Wave, Shelly, or Tuya).
-
Short vs. Long Press Handling:
- Short Press (< 0.5s): Instantly toggles lights or triggers scenes.
- Extended / Long Press (>= 0.5s): Enables smooth dimming up or down.
-
Dimming Direction Helper:
- By creating a simple
input_booleanhelper (e.g.input_boolean.living_dim_direction), the blueprint tracks dimming direction so alternating long presses cycle between brightening and dimming.
- By creating a simple
-
Zero-Delay Bus Processing: Fully compatible with the stateless
myhome.cenandmyhome.cen_plusevents dispatched by the modernized MyHOME integration.
The table below outlines supported hardware gateways, transport layers, queue pacing requirements, and authentication mechanisms:
| Model | Hardware Type | Transport | Default Port | Auth Protocol | Queue Pacing | Features & Firmware Notes |
|---|---|---|---|---|---|---|
| MH200 | Scenario Programmer | TCP/IP | 20000 | Open password / None | 150 ms | Embedded ARM, scenario scheduler, legacy buffer limits. |
| MH200N | Scenario Programmer | TCP/IP | 20000 | Open password / None | 100 ms | Updated network interface, scenario engine. |
| MH201 | Scenario Controller | TCP/IP | 20000 | Open password / None | 80 ms | High-performance DIN-rail scenario controller. |
| MH202 | Scenario Programmer | TCP/IP | 20000 | Open password / None | 50 ms | High-speed ARM CPU, expanded memory and scenario memory. |
| F452 | Web Server IP | TCP/IP | 20000 | Open password / None | 150 ms | Early generation IP gateway. |
| F453AV | Audio/Video Web Server | TCP/IP | 20000 | Open password / None | 120 ms | Supports door entry and basic web control. |
| F454 | Web Server IP | TCP/IP | 20000 | Open numeric password | 80 ms | Dual bus interface, widely deployed standard DIN gateway. |
| F455 | Advanced IP Gateway | TCP/IP | 20000 | Open numeric password | 50 ms | High-throughput industrial gateway. |
| MyHomeServer1 | Modern IoT Gateway | TCP/IP | 20000 | HMAC-SHA2 (SHA-256) | 30 ms | Fast SoC, alphanumeric credentials, cloud integration bridge. |
| F461 | Next-Gen DIN Server | TCP/IP | 20000 | Alphanumeric / HMAC | 20 ms | Latest generation BTicino DIN-rail server/gateway. |
| Legrand 3578 | OpenZigBee USB Interface | Serial USB | /dev/ttyUSB* |
None (Serial bypass) | 40 ms | 19200 baud, 8N1, ZigBee wireless SCS bridge (#<unit_id> addressing). |
OpenWebNet messages always begin with * and end with ##. Fields are separated by *:
-
Standard Command / Status Message:
*WHO*WHAT*WHERE##Example:
*1*1*21##(Turn ON light at address A=2, PL=1) -
Dimension Request (Query):
*#WHO*WHERE*DIMENSION##Example:
*#4*1*0##(Query measured temperature of Zone 1) -
Dimension Writing (Command with Parameters):
*#WHO*WHERE*#DIMENSION*VAL1*VAL2*...*VALn##Example:
*#16*1*#1*30##(Set volume of audio Amplifier 1 to 30%) -
Dimension Response (Status Report):
*#WHO*WHERE*DIMENSION*VAL1*VAL2*...*VALn##Example:
*#4*1*0*0215*1##(Zone 1 temperature is 21.5 °C, Heating mode) -
Acknowledge (ACK / NACK):
-
*#*1##: ACK (Command accepted by gateway/bus) -
*#*0##: NACK (Command rejected, syntax error, or buffer busy)
-
To capture raw OpenWebNet frames from physical hardware or diagnostic sessions:
- Add the Lovelace Bus Monitor Card to your dashboard:
type: custom:myhome-bus-card
- Operate your devices (e.g. adjust a DALI color ballast, toggle a dry contact switch, or change audio volume).
- Click
📋 Report Issue / Copy Traceto copy a sanitized diagnostics report with the exact bus frames.