Flow Actions Input_group_logtimeline
Write a message to both the local log and Homey's Timeline, with optional log metadata.
Message accepts text and Homey tokens. It can also use BLL coding.
App/group is optional and appears in the log's App column; keep it at most 100 characters. Severity and facility are optional: see levels and categories. Message and group support BLL coding.
This action has no output tokens. When Show group in Timeline is enabled, the Timeline message is prefixed with [group]; severity and facility are not included in that notification. Timeline errors are logged where possible.
Use a door sensor's opened trigger. In Then, add this grouped card with Message Front door opened, App/group Entry, Severity Notice, Facility Device. Save and open the door. The log shows the group and metadata; with the setting enabled the Timeline shows [Entry] Front door opened.