Arduino library for the TSW10 analog turbidity sensor.
Experimental
This library is to make measurements with the TSW-10 turbidity sensor, e.g. in the SEN0189 of DFRobotics. It is not to replace a professional turbidity sensor, however it should be possible to get reasonable indications of turbidity.
Turbidity is an important and widely used indication of the clarity and quality of the water. The less turbid or the cleaner the water the less it might be polluted. Note that not all turbidity is pollution, in a fast flowing river there are always fine grains of sand in the stream.
Turbidity is expressed in units of NTU (Nephelometric Turbidity Units) or FTU (Formazin Turbidity Units). This library only supports NTU as the datasheet of the TSW-10 provides an indicating graph. This graph uses a 5 Volt so for 3.3V processors adaptions are needed, e.g. a voltage converter.
The library is meant to be used with an internal ADC, however using an external ADC is possible if one converts the ADC measurements to volts and use volts2NTU(volts).
The library does not support run-time calibration (yet). For now the volts to NTU conversion table in TSW10.cpp file can be adjusted manually in the function volts2NTU(volts). Furthermore one can adjust for power differences by calling begin(volts, steps) again to get some extra accuracy.
WORK IN PROGRESS
The library is not tested with hardware yet.
Feedback as always is welcome.
Some specs.
| range | notes | |
|---|---|---|
| temperature | -30°C ~ 80°C | |
| voltage | 5V | 3.3V devices need |
| current | Max. 30 mA | do not power with an IO pin. |
The scientific literature mentions also FNU, FAU, FBU, FNRU units, which are all different methods of determining turbidity. These include using visible or IR light and using a different detector angle. More information see - https://documents.thermofisher.com/TFS-Assets/LPD/Application-Notes/Turbidity-Units-A-Cloudy-Issue.pdf
Do not apply this product to safety protection devices or emergency stop equipment, and any other applications that may cause personal injury due to the product's failure.
Also important is the calibration of the sensor. Currently not supported other than a graph as defined in the datasheet.
The library does not support run-time calibration (yet). For now the lookup table in TSW10.cpp file needs to be adjusted manually in the function volts2NTU(volts).
Datasheet Sensor
- https://wiki.seeedstudio.com/Grove-Turbidity-Sensor-Meter-for-Arduino-V1.0/
- https://amphenol-sensors.com/en/thermometrics/turbidity/934-tsw-10
- https://documents.thermofisher.com/TFS-Assets/LPD/Application-Notes/Turbidity-Units-A-Cloudy-Issue.pdf
Backgrounder
- https://en.wikipedia.org/wiki/Turbidity
- https://www.sciencedirect.com/topics/medicine-and-dentistry/nephelometry
Libraries
- https://github.com/RobTillaart/TSW10 - this library
- https://github.com/RobTillaart/TSL235R - light to frequency convertor
- https://github.com/RobTillaart/TSL260R - IR to voltage convertor
- https://github.com/RobTillaart/printHelpers - scientific notation et al.
- https://github.com/RobTillaart/map2colour - mapping ranges upon colours.
The TSL sensors can be used for turbidity measurement too. See documents folder.
Not yet (order pending :).
One could use an HC4051 as multiplexer so it uses only one analog port.
- https://github.com/RobTillaart/HC4051 (other multiplexer libs are mentioned there).
#include "TSW10.h"- TSW10(uint8_t analogPin) defines the (internal) analog pin to be used for the measurements.
- bool begin(float voltage, uint16_t maxSteps)
- float getVoltage(uint8_t times = 1) read one or more times the sensor and return the average voltage. The parameter times is constrained between 1..32.
- float getNTU(uint8_t times = 1) read one or more times the sensor and return the average NTU. The parameter times is constrained between 1..32.
- float volts2NTU(float volts) conversion function for volts to NTU, based upon the graph in the datasheet. Can be used with an external ADC.
- uint32_t lastRead() timestamp in millis of the last time a read function was called.
- improve documentation
- get hardware to test (DFRobotics SEN0189).
- add runtime calibration?
- is this possible?
- use fixed NTU levels and change voltage?
- track minimum and maximum turbidity + reset.
- add gradient detection
- uint32_t uptime() { return millis(); };
- add bool maintenanceNeeded() ? (uptime > threshold, reboot proof?)
- add callback function if a certain threshold is met.
- add getFTU() / getFNU() wrappers?
- no data how to do this correctly.