Notifications
You must be signed in to change notification settings - Fork 0
Architecture
Your Name edited this page Jun 24, 2026
·
3 revisions
Home | Overview | Architecture | API | Operations | Validation-Guide
LabTelemetry follows a simple layered architecture:
Telemetry source
-> ingestion command
-> quality evaluation
-> database
-> JSON API
-> dashboard
-
telemetry.models: sensor, reading, and alert persistence models -
telemetry.quality: threshold and drift evaluation rules -
telemetry.management.commands.simulate_telemetry: deterministic telemetry simulation -
telemetry.management.commands.telemetry_simulate: operational wrapper for repeated simulation -
telemetry.management.commands.ingest_telemetry: source-based ingestion command -
telemetry.sources: source adapter abstraction for simulator and Modbus TCP -
telemetry.views: dashboard and JSON API views
-
TelemetrySensor: monitored point, parameter, status, and calibration factor -
TelemetryReading: timestamped raw and calibrated value, source lineage, and quality status -
TelemetryAlert: active or resolved operational alert
The ingestion layer separates data sources from persistence. Each persisted reading stores the logical source name used during ingestion so recent-reading queries retain basic lineage without preserving raw protocol payloads.
Current adapters:
-
SimulatorAdapter: reproducible local runs -
ModbusTCPAdapter: configurable host, port, unit id, and timeout
The simulator remains the default reproducible path. Real Modbus validation depends on an available device or simulator.
The system favors small, explicit boundaries:
- source adapters remain separate from persistence
- quality rules stay in backend code
- JSON endpoints stay simple enough to feed the dashboard directly
- observability remains optional and local-first