Quickstart
This walks the Phase-1 target scenario in the REPL: take a cold, dark A320 on the apron, put the batteries on, then bring in external power and watch the whole AC network wake up. It assumes you have the bindings and CLI installed — see Installation.
Start the REPL:
a320-cliYou land cold & dark on the apron. Nothing is seeded — every pushbutton starts OFF (this is the real cold & dark; see Controls-and-Variables).
a320 [t= 0.0s]> step 1000
stepped 1000 ms (t=1.000s)
a320 [t= 1.0s]> set bat_1 on
bat_1 <- 1
a320 [t= 1.0s]> set bat_2 on
bat_2 <- 1
a320 [t= 1.0s]> watch ELEC_DC_BAT_BUS_IS_POWERED ELEC_AC_1_BUS_IS_POWERED
watching 2 var(s) at 5 Hz - Ctrl+C to stop
* ELEC_DC_BAT_BUS_IS_POWERED 1 <- DC BAT bus comes alive around t=2.0s
ELEC_AC_1_BUS_IS_POWERED 0 (AC stays dead: no AC source yet)
t= 2.00s
^C
[watch stopped at t=3.20s]
The * marks a powered bus. Around t=2.0 s the DC BAT bus flips from 0 to 1 as the battery
contactors close. AC stays dead — there is no AC source yet. Ctrl+C stops watching; the sim keeps
its state.
The bus tie must be in AUTO: with no state seeding, the pushbutton starts OFF and the AC tie contactors would otherwise stay open.
a320 [t= 3.2s]> set bus_tie auto
bus_tie <- 1
a320 [t= 3.2s]> set ext_pwr_avail 1 # world control: the GPU is plugged in
ext_pwr_avail <- 1
a320 [t= 3.2s]> set ext_pwr on
ext_pwr <- 1
a320 [t= 3.2s]> watch ELEC_AC_1_BUS_IS_POWERED ELEC_AC_2_BUS_IS_POWERED ELEC_DC_1_BUS_IS_POWERED ELEC_DC_2_BUS_IS_POWERED
watching 4 var(s) at 5 Hz - Ctrl+C to stop
* ELEC_AC_1_BUS_IS_POWERED 1 <- whole AC network wakes up around t=3.6s
* ELEC_AC_2_BUS_IS_POWERED 1
* ELEC_DC_1_BUS_IS_POWERED 1
* ELEC_DC_2_BUS_IS_POWERED 1
t= 3.60s
Around t=3.6 s the whole AC network wakes up — AC 1/2 powered through the bus-tie contactors, TR 1/2
giving normal potential, DC 1/2 fed via the TRs. You have taken the aircraft from cold & dark to a
fully powered network from a terminal.
watch advances the sim at ~5 Hz and re-renders in place, so you see the contactors sequence — not
just a before and an after. When stdout is piped (for capture/automation) it prints one compact line
per refresh instead.
-
Break something — inject a failure and watch the ECAM react:
See Failures-and-ECAM.
set apu_master on set apu_start on run 65 # APU spins up (~60 s simulated) set apu_gen on fail elec.apu_gen.1 run 5 ecam # APU GEN FAULT + AC ESS BUS FAULT -