3. B&R Automation Studio
This tutorial guides you through the configuration of ros_powerlink_tutorial project in B&R Automation Studio. B&R X20CP PLC is utilized for this purspose, however the same procedure should also work with different B&R POWERLINK compatible hardware.
Open B&R Automation Studio and use Project Wizard to create new project named ros_powerlink_tutorial.
Enter the parameters of new configuration manually or let B&R Automation Studio to identify your hardware
In case of manual configuration, select a specific type of your PLC
Complete your hardware configuration by adding all peripherals, your configuration should look similar to the picture shown below:
If your hardware configuration is ready, you can proceed to importing external fieldbus device:

Add CiA401 Powerlink device to your hardware configuration:
Drag a connection between PLC and particular port of POWERLINK device (representing your PC):
Enter configuration menu of POWERLINK device:
Increase default response time from 22ms to 100ms:
Select which channels from CiA401 profile you want to activate for cyclic exchange:
Your final configuration should look similar to the figure below:
Your project is now configured for communication with ros_powerlink tutorial CPP node.
As a last step you need to upload your configuration to the Compact Flash Card, use standard Offline Install tool provided by B&R Automation Studio:
Select your Compact Flash Card and hit Create Compact flash button:
Insert Compact Flash Card to the PLC and you are ready to communicate over POWERLINK!