Summary

Adds an observed threshold entry for ATA attribute 188 (Command_Timeout) when the value is exactly 0. This fixes incorrect failure rate calculations for drives with zero command timeouts, particularly affecting Seagate drives.

Origin

Changes

  • Adds threshold entry for attribute 188 with Low=0, High=0
  • Includes observed annual failure rate data for this threshold range

Related Issues

Test Plan

  • Verify attribute 188 displays correctly when value is 0
  • Verify Seagate drives with 0 command timeouts show correct status

@Starosdev Starosdev added this to the v1.1.0 - Bug Fixes milestone Nov 30, 2025
@Starosdev Starosdev added bug Something isn't working upstream-pr Upstream PR to merge labels Nov 30, 2025
@Starosdev Starosdev self-assigned this Nov 30, 2025
@Starosdev Starosdev added bug Something isn't working upstream-pr Upstream PR to merge labels Nov 30, 2025
Adds an observed threshold entry for ATA attribute 188 (Command_Timeout)
when the value is exactly 0. This fixes incorrect failure rate calculations
for drives with zero command timeouts, particularly affecting Seagate drives.
@Starosdev Starosdev force-pushed the fix/upstream-pr-551-attr188-zero-value branch from 34e99fb to c86ee89 Compare November 30, 2025 06:42
@Starosdev Starosdev changed the title fix(thresholds): add observed threshold for attribute 188 with value 0 (upstream PR #551) fix(thresholds): add observed threshold for attribute 188 with value 0 Nov 30, 2025
@Starosdev Starosdev merged commit 36b7239 into develop Dec 1, 2025
11 of 13 checks passed