OpenOSC 0.21.0
Warning
Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.
What's new
Redesigned oscilloscope controls (#37, #95, #96)
- F1 hold opens the probe ratio picker for the selected channel.
- F2 hold resets zoom and pan and centers the channel zero levels by default. Choose Reset zoom & pan in Settings to keep the channel zero positions.
- F3 first selects Trigger. Further taps cycle Auto → Normal → Single. Hold F3 for the 50% trigger level. Use MENU from Trigger to choose the source.
- F4 hold opens Cursor settings by default. You can choose Measurements, Acquisition, Record memory, or Interleave CH1 where available.
- AUTO now starts Auto Setup with a tap in the default Quick mapping. Hold it for two seconds to open Zoom & Pan. Choose Classic in Settings → Display → Scope shortcuts to tap for reset pan and hold for Auto Setup.
A tap during Auto Setup cancels it and restores the previous acquisition and any held record. Zoom & Pan changes the visible window without changing the acquisition timebase. In HOLD you can inspect the record and return to the working view when you resume acquisition.
Please test the redesigned controls. Try the AUTO tap and hold, switching back to the Trigger card, and zooming and panning a held record. If you use a different workflow, try the shortcut choices too. Please share your device model, which controls you tried, and what worked or was confusing. Oscilloscope controls on the Wiki · Scope shortcuts · Leave feedback in Discussions
10000:1 probe preset (#97)
Both channels can use the 10000:1 probe preset. The Position card shows X10K. The preset scales voltage readouts for a matching probe. The hardware input limits still apply.
Thanks to @Nikonist and @taylora1-1 for working through the control mapping and use cases.
Testing
Installed 0.21.0 through Recovery on a ZT703S and verified the running version over SCPI. Hardware checks covered the revised trigger workflow, channel selection and the probe picker, Auto Setup cancellation, zoom and pan in RUN and HOLD, and shortcut navigation. Both models' firmware and Recovery builds, native control regressions, and stack-budget checks passed.
Files
| Device | Recovery bootloader | Firmware |
|---|---|---|
| ZT703S | OpenOSC-Recovery-ZT703S.ZTK |
OpenOSC-Firmware-ZT703S.OSC |
| ZT706S | OpenOSC-Recovery-ZT706S.ZTK |
OpenOSC-Firmware-ZT706S.OSC |
Download the files for your model.
Updating
- From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching
.OSCinto/openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION. - Both Recovery packages match 0.20.3 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
- From 0.2.0 or older, or for a new installation — Follow the installation instructions.
Known issues
- Dense two-channel captures with waveform density enabled can reduce the display frame rate.
- In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows
No record to move. Completed records can be panned in HOLD. - Settings are written during an orderly power-off, restart, or entry to Recovery. A loss of power can discard changes made since the last save.
- USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
- On the ZT703S, CH1 interleave applies DC offset correction by default. Run Interleave gain & timing to calibrate gain and timing for the unit.
SHA-256
51355c62afc2498f4d2947275b54fa8d03d8380c304da740f74c7f7494278994 OpenOSC-Firmware-ZT703S.OSC
ceb725d88249b2ccb2b17c8780a1a28a946fe56a4f6ea875e89510bbb0bb208a OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81 OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2 OpenOSC-Recovery-ZT706S.ZTK