OpenOSC 0.21.4
Warning
Work in progress, for enthusiasts only. ZT703S is the main development and hardware test device.
Hardware coverage for the ZT706S is limited.
Install at your own risk. You can go back to the stock firmware.
What's new
Scope trigger level limits (#61)
The arrow at the right edge of the plot pulses for half a second when the trigger level reaches either limit or you press against it. A small warning triangle stays beside the arrow while the level is at the limit. The trace and soft keys stay visible. In the Trigger panel, the Level row shows (min) or (max).
Thanks to @art-thunder for the suggestion.
Hold MODE to switch between the scope and generator
Hold MODE for 1 s to switch directly between Oscilloscope and Generator. Holding MODE from Multimeter opens the oscilloscope. A tap still cycles through all three screens. Each hold switches once. See Controls.
Testing
Installed the 0.21.4 application package through Recovery on a ZT703S. Verified both trigger limits in HOLD, including the pulse, the persistent marker and an inward step on the same record. Checked MODE holds in both directions and from the multimeter, the short-press cycle, and the USB Remote lock. Native input and rendering tests and stack checks passed. Both models passed application and Recovery builds and package validation.
Files
| Device | Recovery bootloader | Firmware |
|---|---|---|
| ZT703S | OpenOSC-Recovery-ZT703S.ZTK |
OpenOSC-Firmware-ZT703S.OSC |
| ZT706S | OpenOSC-Recovery-ZT706S.ZTK |
OpenOSC-Firmware-ZT706S.OSC |
Download the files for your model.
Updating
- From 0.3.0 or newer — Hold F2 at startup to open Recovery. Copy the matching
.OSCinto/openosc/UPDATE/. Select UPDATE FIRMWARE, choose the image, select CONFIRM, and press MENU. When the update completes, select START APPLICATION. - Both Recovery packages match 0.21.3 byte for byte. If you already have Recovery from that release, only the firmware update is needed.
- From 0.2.0 or older, or for a new installation — Follow the installation instructions.
Known issues
- CH1 interleaving is experimental on the ZT703S. Extra noise can still be visible when both ADCs are active at 280 MS/s. On-device offset and gain/timing calibration is available.
- Dense two-channel captures with waveform density enabled can reduce the display frame rate.
- In capture configurations with a single slot, arming a capture can reuse the previous record's memory. WAIT then shows
No record to move. Completed records can be panned in HOLD. - Settings are saved at an orderly power-off, restart or Recovery entry. Changes made since the last save can be lost if power is interrupted.
- USB data requires the 200/100 performance profile. USB hubs can cause disconnects.
SHA-256
8a826b3dfa0e21086774a2a4cb74e1adf4ff774a8fd33d02b7326a0ccfa60266 OpenOSC-Firmware-ZT703S.OSC
e94cf4afbcdc8b825be02b76ba5a7198d194f435f6f6acc8c6e635f189a4c180 OpenOSC-Firmware-ZT706S.OSC
a389038d3aeec07168e0cc07d5f311815ca1054bf2f7c45a2c7b168680862d81 OpenOSC-Recovery-ZT703S.ZTK
6f1db91d198f5c406676c9e5751b1e73a69557c21dd63721c6a79180eb876fd2 OpenOSC-Recovery-ZT706S.ZTK