The same keys work the same way on every screen. Each screen gives F1–F4 its own meaning; the labels above F1–F4 always show what each key does right now.

Keys

Key Short press Hold
MODE Oscilloscope → Multimeter → Generator → Oscilloscope. Closes an open panel Hold for 1 s to switch between Oscilloscope and Generator. From Multimeter, go to Oscilloscope
MENU Opens the panel of the current screen; in a panel or menu, takes the selected row 1 s: Settings
HOLD / SAVE Oscilloscope: Run/Stop. Multimeter: HOLD. Generator: output on/off 1 s: screenshot of the screen
AUTO / RANGE Oscilloscope Quick: Auto Setup or cancel. Classic: reset pan or cancel. Multimeter: manual range / next range 2 s: oscilloscope Quick opens Zoom & Pan; Classic starts Auto Setup. Multimeter: auto range
REL / Power Oscilloscope changes the measurements page. Multimeter toggles relative measurement The "Hold to power off" bar starts at 0.5 s. The device switches off and saves settings at the configured hold time (1, 1.5 or 2 s, default 2 s). Release earlier to cancel
F1–F4 Screen-specific, see each instrument page In the oscilloscope, F1 opens Probe, F2 resets the view, F3 sets pretrigger to 50% and centres the trigger level on the signal, and F4 opens a configurable panel. Oscilloscope keys
Arrows Change the selected parameter; in panels, move between rows Repeat (after 0.4 s, every 80 ms)

A hold never also triggers the short-press action. Keys held while the device starts must be released first. The MODE shortcut is available from OpenOSC 0.21.4 and uses the same panel-closing behavior as a tap. USB Remote locks MODE.

Panels and menus

The instrument panels (MENU on a screen) and Settings (hold MENU) work the same way. Each row is a list, a switch, a number, an action or a sub-page.

You are on Keys
The rows ↑/↓ select a row. MENU opens a list, flips a switch, starts editing a number, runs an action or opens a sub-page. → also opens a sub-page, selects the next choice or flips a switch. Choices and switches take one step per press. F4 or ← goes back one level
An open list ↑/↓ choose (the current value is marked with <). MENU takes it. F4 or ← closes without a change
A number being edited ←/→ (and ↑/↓) step the value. MENU keeps it. F4 restores the value it had before you started

When a change takes effect:

  • Oscilloscope and generator panels: field by field. A list choice or a switch applies at once; a number applies when you press MENU. Stepping a number does not restart the capture or the generator.
  • Multimeter panel: changes apply at once.
  • Settings: choices apply when selected, and numbers are kept with MENU. Brightness previews as you step. F4 restores the original value.
  • Settings and the theme are written to the storage when you switch the device off, restart it or enter Recovery. A battery pull, a crash or a reset loses the changes made since then.
  • If the device refuses a change (for example, switching off the last enabled channel), the row shows the value actually in use and a message explains why.

MODE, entering USB Remote mode or powering off while a number is being edited works like F4: the unfinished edit is dropped.

Status bar

The top line shows the run state, trigger, the FPS or sample rate (Settings → Display → Top bar counter), record memory, USB and battery. On the oscilloscope the run state reads STOP in HOLD, TRIG'D while frames trigger and AUTO while Auto mode runs free; the multimeter shows LIVE, HOLD and REC while CSV logging runs.

When a menu continues on another page, More ↓ appears under the rows.