3 changes: 2 additions & 1 deletion src/CNCULT.CPP
Original file line number Diff line number Diff line change
Expand Up @@ -1832,7 +1832,8 @@ CULT( "wrDHWSYS", DAT, DHWHEATREC_OWNTI, NO_INP|RDFLIN,0,0, TYREF, &WSiB,
CULT( "wrMult", DAT, DHWHEATREC_MULT, 0, 0, VEOI, TYSI, 0, 1, N, N),
CULT( "wrType", DAT, DHWHEATREC_TYPE, 0, 0, VEOI, TYCH, 0, C_DWHRTYCH_VERT, N, N),
CULT( "wrConfig", DAT, DHWHEATREC_CONFIG, 0, 0, VEOI, TYCH, 0, C_DWHRCFGCH_EQUAL, N, N),
CULT( "wrCSARatedEF",DAT, DHWHEATREC_EFFRATED, RQD, 0, VHRLY, TYFL, 0, .5f, N, N),
CULT( "wrCSARatedEF",DAT, DHWHEATREC_EFFRATED,RQD, 0, VHRLY, TYFL, 0, .5f, N, N),
CULT( "wrDTDrain", DAT, DHWHEATREC_DTDRAIN, 0, 0, VHRLY, TYFL, 0, 4.6f, N, N),
CULT( "wrFxServed", DAT, DHWHEATREC_FXSERVED,0, 0, VEOI, TYSI, 0, 1, N, N),
CULT( "wrHWEndUse", DAT, DHWHEATREC_HWENDUSE,0, 0, VEOI, TYCH, 0, C_DHWEUCH_SHOWER, N, N),
CULT( "endDHWHEATREC", ENDER, 0, 0, 0, 0, 0, 0, 0, N, N),
Expand Down
5 changes: 5 additions & 0 deletions src/CNRECS.DEF
Original file line number Diff line number Diff line change
Expand Up @@ -3327,6 +3327,8 @@ RECORD DHWSYS "DHWSys" *RAT // input / runtime DHW system
*declare "DHWMTR* ws_pWHhwMtr; DHWMTR* ws_pFXhwMtr;" // resolved DHWMTR pointers

// mixed and hot water use for this DHWSYS (w/o ws_mult)
*h *e FLOAT ws_whUseNoHR; // current hour virtual hot water use w/o heat recovery, gal
// re verification / accounting of DWHR results
*h *e *nest DHWMTR_IVL ws_fxUseMix // current hour total (mixed) water use at fixtures, gal
*h *nest DHWMTR_IVL ws_fxUseMixLH // prior hour total (mixed) water use at fixtures, gal
*h *e *nest DHWMTR_IVL ws_whUse // current hour hot water use (at ws_tUse), gal
Expand Down Expand Up @@ -3582,6 +3584,9 @@ RECORD DHWHEATREC "DHWHeatRec" *RAT // input / runtime drain water heat recovery

*h FRAC wr_effRated // rated effectiveness (generally CSA rating value)

*h FLOAT wr_dTDrain // water temp drop from fixture mixed temp to drain, F
// td = tFxMix - dTDrain; default = 4.6 F

*s *e FLOAT wr_eff // effectiveness under current conditions

*r FLOAT wr_fWeight // weighting factor for results
Expand Down
89 changes: 42 additions & 47 deletions src/DHWCalc.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -688,9 +688,12 @@ RC DHWSYS::ws_DoHour( // hourly calcs
if (pWDU)
{ // accumulation DHWDAYUSE input to tick bins and total use
rc |= pWDU->wdu_DoHour( this); // accum DAYUSEs
ws_whUseNoHR = ws_whUse.total; // more added in ws_DoDWHR()
if (ws_wrCount && ws_iTk0DWHR < ws_iTkNDWHR)
rc |= ws_DoDWHR(); // modify tick values re DWHR
}
else
ws_whUseNoHR = ws_whUse.total;

if (!ws_HasCentralDHWSYS())
{ DHWSYS* pWSChild;
Expand All @@ -700,10 +703,7 @@ RC DHWSYS::ws_DoHour( // hourly calcs
}
}

#if 0
ws_fxUseMix.wmt_Finalize();
ws_whUse.wmt_Finalize();
#endif
// ws_whUseNoHR ??

#if defined( _DEBUG)
// check: compare tick totals to full hour values
Expand Down Expand Up @@ -855,21 +855,24 @@ RC DHWSYS::ws_DoDWHR()
{
RC rc = RCOK;

#if 0
if (Top.jDay == 91 && Top.iHr == 20)
printf( "\nHit");
#endif

// loop ticks that could include DWHR draws
// ws_qDWHR = 0.f; ... in ws_DoHour
double qRWHSum = 0.;
double whUseTot = 0.; // hour total hot water use, gal
double whUseTotNoHR = 0.; // check value: hour total hot water use w/o HR, gal
double tHotFXAvg = 0.;
// ws_whUseNoHR = 0.; // check value: hour total hot water use w/o HR, gal
// init'd by caller
int nTk = Top.tp_NHrTicks();
int nWarmup = 0;
for (int iTk=0; iTk < nTk; iTk++)
{ DHWTICK& tk = ws_ticks[ iTk];
whUseTot += tk.wtk_whUse; // total use not including draws possibly modified by HR
whUseTotNoHR += tk.wtk_whUse;
int nD = tk.wtk_dwhrDraws.size();
#if 0
if (nD == 0)
continue;
#endif
#if 0
if (nD > 1)
printf( "\nMultiple draws");
Expand All @@ -886,33 +889,30 @@ RC DHWSYS::ws_DoDWHR()
{ DWHRUSE& hru = tk.wtk_dwhrDraws[ iD];
const DHWUSE* pWU = hru.wdw_pDHWUSE;
fxUseMix += hru.wdw_vol;
float fFullTemp = hru.wdw_volHR / hru.wdw_vol;
if (fFullTemp < 1.f)
nWarmup++;
float fHotNoHR;
pWU->wu_CalcHotF( ws_tUse, ws_tInlet, fHotNoHR);
whUseTotNoHR += hru.wdw_vol * fHotNoHR;
ws_whUseNoHR += hru.wdw_vol * fHotNoHR;
float fWeightTot = 0.f;
DHWHEATREC* pWR;
RLUPC( WrR, pWR, pWR->ownTi == ss)
{ float fWeightAdj = pWR->wr_fWeight * fFullTemp;
{ // weight=what fraction of this DHWHEATREC contributes
// wr_fWeight based on # showers etc
// adjust for warmup delay via volHR/vol
float fWeightAdj = pWR->wr_fWeight * hru.wdw_volHR / hru.wdw_vol;
if (fWeightAdj < .0001f)
continue; // no effect (duplicate, mult=0, ...)
#if 0
if (fFullTemp > 0.f && fFullTemp < 1.f)
printf( "\nPartial '%s'", name);
#endif
// float tHotFX = fFullTemp*ws_tUse + (1.f - fFullTemp)*ws_tInlet;
float tHotFX = ws_tUse;
float qR, qRWH;
float whUse = pWR->wr_CalcTick( hru.wdw_vol, pWU->wu_temp, tHotFX, ws_tInlet,
float whUse = pWR->wr_CalcTick( hru.wdw_vol, pWU->wu_temp, ws_tUse, ws_tInlet,
tk.wtk_whUse, qR, qRWH);
#if 0
if (pWR->wr_eff < 0.65f)
printf( "\nEff = %0.3f", pWR->wr_eff);
#endif
fWeightTot += fWeightAdj;
whUseWt += whUse * fWeightAdj;
qRWt += qR * fWeightAdj;
qRWHWt += qRWH * fWeightAdj;
tHotFXAvg += whUse * tHotFX * fWeightAdj;
}
} // end heat recovery loop
if (fWeightTot < .9999f)
whUseWt += (1.f - fWeightTot) * hru.wdw_vol * fHotNoHR; // not right for partial?
} // end draw loop
Expand All @@ -921,32 +921,31 @@ RC DHWSYS::ws_DoDWHR()
float tO = ws_tInlet;
if (tk.wtk_whUse > 0.)
tO += qRWHWt / (waterRhoCp * tk.wtk_whUse);
else
printf( "\nwkt_whUse = 0");
else if (qRWHWt > 0.f)
printf("\nWhat?");

tk.wtk_tInletX = ws_AdjustTInletForSSF( tO);
whUseTot += whUseWt; // hour total hot water at heater
qRWHSum += qRWHWt;
ws_qDWHR += qRWt; // accum to hour total heat recovered
} // end tick

#if 0 && defined( _DEBUG)
if (frDiff( float( whUseTot), ws_whUse.total, .001f) > .001f)
printf( "\nMismatch!");
#endif

// calc hour average adjusted inlet and hot water temps
float tInletXNoSSF = ws_tInlet;
if (qRWHSum > 0.)
{ tInletXNoSSF = ws_tInlet + qRWHSum / (waterRhoCp * whUseTot);
{ tInletXNoSSF = ws_tInlet + qRWHSum / (waterRhoCp * ws_whUse.total);
ws_tInletX = ws_AdjustTInletForSSF( tInletXNoSSF);
}
tHotFXAvg /= whUseTot;

#if defined( _DEBUG)
float qXNoHR = whUseTotNoHR * waterRhoCp * (ws_tUse - ws_tInlet);
float qX = whUseTot * waterRhoCp * (ws_tUse - tInletXNoSSF);
float qXR = qXNoHR - qX;
if (frDiff(ws_qDWHR, qXR, .01f) > .001f)
printf( "\nDHWSYS '%s': ws_DoDHWR balance error (nWarmup=%d)", name, nWarmup);
#if 0
else if (nWarmup > 0)
printf( "\nDHWSYS '%s': ws_DHWR nWarmup=%d", name, nWarmup);
#endif
float qXNoHR = ws_whUseNoHR * waterRhoCp * (ws_tUse - ws_tInlet);
float qX = ws_whUse.total * waterRhoCp * (ws_tUse - tInletXNoSSF);
if (frDiff(qX+ws_qDWHR, qXNoHR, 1.f) > .001f)
printf( "\nDHWSYS '%s': ws_DoDHWR balance error", name);
#endif

return rc;
Expand Down Expand Up @@ -2374,7 +2373,9 @@ int DHWHEATREC::wr_IsEquiv(
&& wr_fxServed == wr_fxServed
&& wr_hwEndUse == wr.wr_hwEndUse // future proof
&& !ISNANDLE( wr_effRated) && !ISNANDLE( wr.wr_effRated)
&& wr_effRated == wr.wr_effRated;
&& wr_effRated == wr.wr_effRated
&& !ISNANDLE( wr_dTDrain) && !ISNANDLE( wr.wr_dTDrain)
&& wr_dTDrain == wr.wr_dTDrain;

return bEquiv;
} // DHWHEATREC::wr_IsEquiv
Expand All @@ -2392,16 +2393,10 @@ float DHWHEATREC::wr_CalcTick( // calculate water quantities for tick
// returns hot water use at WH, gal

{
#if 0
float vd = DWHRUse.wdw_volHR; // useful drain vol = fixture hot vol, gal

const DHWUSE* pWU = DWHRUse.wdw_pDHWUSE;
float td = pWU->wu_temp; // drain temp = fixture mix temp
#endif

float vp, whUse, tpO;

float td = min( tUseFX, tHotFX); // drain water temp
// drain water temp
float td = max( tpI, min( tUseFX, tHotFX) - wr_dTDrain);

if (wr_FeedsFX())
{ // HX feeds fixture and possibly WH
Expand Down