Notifications
You must be signed in to change notification settings - Fork 357
Battery: Ford F‐150 Lightning
Caution
Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.
The model years 2022-2025 came with the following batteries
- 107kWh gross (98kWh net usable)
- 143kWh gross (131kWh net usable)
There are stickers on the battery that informs gross capacity
| Parameter | Value |
|---|---|
| Pack Size (L × W × H) | 38"wide 105"long 12.5" high back half(52") portion 6.5" front half portion with the exception of where the bms is. That part is 8" high. |
| Weight |
Battery holder frame design:
For this battery type, use the option called "xyz" under the "Battery Protocol" section
Part numbers for connectors/cables, along with purchase links to ebay/aliexpress
| Component | Part Number | Purchase Link |
|---|---|---|
| eBay / AliExpress |
A replacement LV connector can be purchased from AliExpress. https://www.aliexpress.com/item/1005008121256506.html
Detailed LV connector C144 pin description
For communication only: Connect the following pins:
- Pin 1 to 12V constant (BMS+)
- Pin 6 to 12V constant
- Pin 26 to GND for 12V
- Pin 15 or 21 to CAN-L on Battery-Emulator
- Pin 16 or 22 to CAN-H on Battery-Emulator
For communication AND contactors: Connect the following pins:
- Pin 1 to 12V constant (BMS+)
- Pin 5 to 12V constant
- Pin 6 to 12V constant
- Pin 8 to 12V constant (Closing battery contractors)
- Pin 25 to GND for 12V
- Pin 26 to GND for 12V
- Pin 15 or 21 to CAN-L on Battery-Emulator
- Pin 16 or 22 to CAN-H on Battery-Emulator
Tip: use pin 15 and 16 for CAN Communication. Use pin 21 and 22 to add a 120Ω terminating resistor
Battery uses 1.4 amps to run the 12v 1mm2 cable should be enough.
Note: The battery does NOT contain a terminating resistor, so it is a good idea to add a 120 Ohm resistor between CAN-L and CAN-H on the battery side.
| Parameter | Value |
|---|---|
| 12V Consumption — Peak Start | 2.0A |
| 12V Consumption — Continuous | 1.5A |
| CAN type | CAN |
| Contactor Control | CAN-controlled |
| Parameter | Value |
|---|---|
| Interlock Required | Yes |
| Number of Interlocks |
The interlocks on these connectors need to be seated: