Future improvements
In hindsight it might have been better to have two separate and specific devices: one for strain gauge acquisition and another for generic ADC. This would have allowed much smaller boards and to place the ADC stage right at the strain gauge without needing to route long cables that make the acquisition prone to noise distortion. On the flip side, this would have resulted in much more expensive boards (each of them would have required an MCU).
For the future, consider using the An2CAN as is for normal acquisitions and designing a second one dedicated to strain gauges. This second system would be made of multiple ADC stages that connect to a master (which could be the An2CAN as described here) to then perform pre-processing or DSP and then forward the data on a CAN bus. This solution would allow to use a single MCU on the master board, while leaving the front-ends and the ADC on low-noise slaves.