v1.22.7 — BUH counter fix: wall-time + native-first


🐛 What Was Wrong

runtime_buh_today was 2× too high when both BUH Step1 and Step2 were active. A prod-1 user reported 90 min of backup-heater runtime on a day the firmware counter showed 42.6 min.

Root cause: each tick added dt_s (30s) to both _buh_step1_s and _buh_step2_s, then the sensor summed them — 60s per 30s wall-time.

Related: ESPAltherma v2 exposes precise firmware counters (Stats: Backup heater today, Stats: Defrosts today, Stats: Compressor starts today) that were unused. We now prefer them with computed fallback.


✅ What Changed

Wall-time counter (core fix)

  • New _buh_total_s — max 1× dt_s per tick regardless of step1/step2
  • runtime_buh_today reads _buh_total_s instead of step1_s + step2_s
  • step1_s / step2_s kept as diagnostic detail in attrs
  • Restore migration: pre-v1.22.7 payloads (no buh_total_s) backfill via max(step1, step2)

Native-first for ESPAltherma v2

New engine/runtime_source.py with strict resolvers:

Counter Priority
BUH today Stats: Backup heater today (min) × 60 → computed
Defrosts today Stats: Defrosts today → computed
Compressor starts Stats: Compressor starts today → computed
Compressor runtime computed primary (firmware resets on reboot)

Each sensor exposes a source attribute (native / computed).

Hardening

  • Strict isinstance(attrs, dict) — reject MagicMock (float(Mock) == 1.0 false positive)
  • Safe isinstance(snap, dict) guards in sensor accessors

CI infrastructure

  • Pre-push hook skips full pytest suite on branch-deletion pushes — from 500s+ to <2s.

Not changed

  • buh_excessive alert — 7-day ratio, not today's counter
  • COP / heat / electricity today — already use power_sensor + cop_sensor
  • Defrost duration — no native field on ESPAltherma
  • Compressor runtime — computed-primary per user preference

🧪 Testing & quality

  • 5,960 tests pass, 100% coverage
  • 20 new tests in test_v1227_buh_walltime.py
  • Suite: 504s (was 528s, −4.5% via --dist worksteal)
  • Ruff clean on changed files
  • No regression — v1.22.6 FR / DAV3 / LWT card preserved

📊 Impact

User Before After
Prod-1 (v2 ESPAltherma) 5436 (90.6 min) 2556 (42.6 min), source: native
v2 with Stats: computed only firmware-exact, source: native
v1 (no Stats:) double-counted wall-time computed, source: computed

⚙️ Upgrade

No action required. Auto-updates via Marketplace (HA 2026.11+) or HACS.

After upgrade, runtime_buh_today corrects from next coordinator tick (~30s). Historical daily_summary per-cycle records unaffected.

🔗 Links


☕ Support

Daikin Cycle ML is free, local-only, and open-source. If it has helped you optimize your heat pump or save on energy costs:


LWT Fine-Tuning card
NEW in v1.22.6: LWT Fine-Tuning card · Advice / Buckets / Analysis / Live · all local, all free