READ_MCLPOWER
Reads the power reading from an attached Mini-Circuits power meter. The
power meter must be connected to the USB port on the rear of the radio.
The power is sample for 1/2-second before the reading is provided so
this command will consume a half-second of wall clock minimum. Providing
the frequency in MHz is optional (see MCL power meter software guide for
details on when or why this may be necessary).
C[D]<seq_number>|read_mclpower <frequency_MHz>
Example:
C19|read_mclpower 14
See Response Format
for details on the format of the response messages from the radio
Hex Response
Message
Debug Output / Meaning
00000000
OK
5000008D
Power meter not successfully read or not connected
Responses
is the value in dBm read from the power meter and may be
positive or negative