Repository files navigation

tm

semi-real time telemetry data sharing

environment

  • libev
  • unix like os
  • every node on the same network

overview

The purpose of the system is to share current data in the network like temperature, music volume and other relatively small sensor data. All of the data in the system can be found in a directory in the filesystem (TM_DATADIR). The system keep this directory up to date. Every sensor data is a file in the directory. The filename contains information regarding the sensor type, sensor id and source node. The file modification time set to the data creation time. After a certain time (TM_MAXAGE) all not updated data files are removed.

details

data filename structure

  • Sensor type (2char)
  • Sensor instance (2 hex digits, MSBs: priority)
  • Source node id or "xxx..." if the data is global (8char)

sensor priority

Encoded in sensor instance number in the two most significant bits.

MSB hex priority frequency
00 0x0x urgent 1 sec
01 0x4x normal 5 sec
10 0x8x low 61 sec
11 0xcx sporadic once1

1 appears in every cycle for 1 minute after generated

sensor data content

One line of ascii7 text without space. Binary data can be base64 encoded. Maximum length is 256 bytes.

sensor input

Local sensors can feed data to the system in one of two ways:

  • Writing a file to the "input" directory, where the filename should be the sensor type and instance and the content should be the measurements

    echo -n "00:02" >/var/run/tm_data/in/TI40

  • Sending the measurement to the tcp input port to localhost (name, content)

    echo "#bTI4000:02" | socat - TCP:127.0.0.1:7699

  • Quit local instance with a "quit" message to the local input port

    echo "quit" | socat - TCP:127.0.0.1:7699

misc

name value config
data directory /tmp/tm_data TM_DATADIR
input directory /tmp/tm_data/in -
local input port 7699 -
buffer size 4096 TM_BUFSIZE
max data age 3600 TM_MAXAGE
lockfile /var/lock/tm.lock TM_LOCKFILE
max sensor data 256 -
sensor heartbeat 5000 ms -
system heartbeat 1000 ms -
global prefix GL -
heartbeat prefix HB -
UDP bus port 7697 -
TCP fwd port 7698 -
log ident string tmd TM_LOG_IDENT
error limit 30 TM_MAXERR

Disclaimer