This repository provides the simulators for ESS, Solar and the Recloser. When building this repository a single jar is produced with differen entry points to start the different simulators. Each simulator has a properties files to define the OpenFMB ID information and how the simulator operates. In addition the Island Balancer application can be initiated by the same jar with an entry point. The Island Balancer application subscribes to the loadpublisher, solar, recloser and ESS to determine the state of the microgrid and the appropriate discharge of the ESS during an microgrid island state.
NOTE: This project is used in the Dtech Demo. Refer to Wiki for information on DTech Demo.
To start the battery simulator
java -cp openfmb-simulators-0.0.5-SNAPSHOT-jar-with-dependencies.jar com.greenenergycorp.openfmb.simulator.battery.BatterySimulatorTo start the solar simulator
java -cp openfmb-simulators-0.0.5-SNAPSHOT-jar-with-dependencies.jar com.greenenergycorp.openfmb.simulator.solar.SolarSimulatorTo start the recloser simulator
java -cp openfmb-simulators-0.0.5-SNAPSHOT-jar-with-dependencies.jar com.greenenergycorp.openfmb.simulator.recloser.RecloserSimulatorTo start the balancer application
java -cp openfmb-simulators-0.0.5-SNAPSHOT-jar-with-dependencies.jar com.greenenergycorp.openfmb.simulator.balance.IslandBalancerTo run another simulator you will need to modify the simulator properties file. A modified properties file for solar has been provided below. This can be copy and pasted in to a file called solarsim2.properities.
New properites file for solar simulator
device.logicalDeviceID=DEMO.MGRID.SOLAR.2
device.mRID=DEMO.MGRID.SOLAR.2
device.name=Solar
device.description=Solar
value.scale=0.01
value.offset=0.0
value.jitterChance=0.2
value.jitterPercent=0.05
topic.SolarReadingProfile=openfmb/solarmodule/SolarReadingProfile
topic.SolarEventProfile=openfmb/solarmodule/SolarEventProfile
data.file=data/load.tsv
config.intervalMs=1000
Note that the key items to change are the ID and MRID to avoid conflict. In this case we incremented the suffix to 2. To run the simulator with this property file you will need to be in the same directory as the jar to use the following command.
java -cp openfmb-simulators-0.0.5-SNAPSHOT-jar-with-dependencies.jar -Dconfig.sim.path=solarsim2.properties com.greenenergycorp.openfmb.simulator.solar.SolarSimulator
The HMI will now show a new solar device on the web page.
Please refer to the Wiki pages for the Demonstration and Prerequisites for the demo and these cooresponding repository projects.
In order to build this project you must first build the openfmb-adapters project to create the XML to MQTT bindings.
git clone https://github.com/openfmb/openfmb-simulators.git
cd openfmb-simulators
mvn clean install -Pslf4j-simpleThe build jar is put in the target directory and needs to be moved to the main directory where the properities files are located.
The following is a description of the simulators and the associated property files. These properties can be modified to reflect changes in the simulation. As a rule the ID and MRID are always the same for a device. The other properties are how the simulator operates and capacities of devices where appropriate. In addition the topics being used are defined and can be examined with MQTT Spy.
The configuration of each simulator and the application resides in the property files.
This process simulates a battery that can be in standby mode, setpoint-driven mode, and either islanded or grid connected. It subscribes to the BatteryControlProfile for setpoints.
The ESS simulator parameters are found in the batterysim.properties file. Configuration for the battery simulator resides here.
This process reads a file of 24 hours of one-hour output data, interpolating values to produce updates at a configurable interval.
The PV simulator parameters are found in the SolarSim.properties file. Configuration for the solar simulator resides here.
This process simulates an open/closed breaker, handling RecloserControlProfiles to execute the flips. It also subscribes to all battery, solar, and resource power values to calculate a flow across the PCC.
The Recloser Simulator parameters are found in the RecloserSim.properties file. Configuration for the recloser simulator resides here.
This process subscribes to the recloser and detects islanding and grid connected modes. In Island mode it will set the battery to Island mode and issue setpoints to the battery to balance between microgrid generation and load. Configuration for the balancer application resider here.
Each properties files defines the following.
device.logicalDeviceID
device.mRID
device.name
device.description
# topics to subscribe or publisher too
topic.<profile>=
# parameters for the simulator including publish rate if appropriate
Green Energy Corp, Daniel Evans
If you'd like to contribute, please fork the repository and use a feature branch. Pull requests are warmly welcome.
Please review the CONTRIBUTING file.
See the APACHE_FILE_HEADER file for more info.