@jjb jjb commented Jan 15, 2024

  • shutdown outside of the handler
  • wip

jjb added 3 commits January 14, 2024 18:31
because, i think but haven't totally verified, rufus will create
mutexts sometimes which is not allowed in a signal handler
@jjb jjb changed the title no mutex in shutdown without loop no mutex in shutdown Jan 15, 2024
@jjb
Copy link
Owner Author

jjb commented Jan 15, 2024

ruby-clock-2.0.1/lib/ruby-clock.rb:28:in `write': deadlock; recursive locking (ThreadError)
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:28:in `puts'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:28:in `puts'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:28:in `shutdown'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:37:in `block (2 levels) in listen_to_signals'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:53:in `write'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:53:in `puts'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:53:in `puts'
	gems/ruby-clock-2.0.1/lib/ruby-clock.rb:53:in `run_jobs'
	gems/ruby-clock-2.0.1/exe/clock:84:in `<top (required)>'

@jjb jjb closed this Oct 17, 2024