Skip to content

Comms Path Configuration

github-actions[bot] edited this page Sep 4, 2026 · 9 revisions

Configure a comms path for Home Assistant with CTPlus

← Documentation · Panel setup · Configuration

This guide creates a dedicated Computer Event Driven Ethernet communication path for TecomHA. The screenshots show example values; use the IP address, ports, credentials and encryption key for your own installation.

Important: Back up the panel configuration before making changes. In CTPlus, open Administration and export the panel and system configuration as appropriate for your installation.

CTPlus Administration tab with the Export panel and Export system options highlighted

1. Create a dedicated communication path

Use a spare communication-path record and give it a descriptive name such as HomeAssistant. Home Assistant must not share the path used by the CTPlus desktop application.

On the Main tab, configure:

Setting Value
Interface location On Board
Format Computer Event Driven
Interface port Ethernet

TecomHA supports either the classic Security password method or User name and password authentication. Configure only the method you intend to use, then enter the same credentials in Home Assistant.

CTPlus Main tab configured for a HomeAssistant communication path

2. Configure connection control

On the Connection control tab, enable:

  • Always connect
  • Stay connected on empty buffer
  • Control command
  • Isolated inputs trigger path

CTPlus Connection control tab with the required options enabled

3. Configure the event filter

On the Filter tab, enable the event categories TecomHA needs:

  • Report alarm events
  • Report connection events
  • Report system alarms
  • Report communication events
  • Report access events
  • Multi-break alarms
  • Multi-break restores
  • Report open/close

An event category excluded here will not be delivered to Home Assistant.

CTPlus Filter tab with the TecomHA event categories enabled

4. Disable test calls

On the Test calls tab, set Test call type to No test call.

CTPlus Test calls tab set to No test call

5. Leave dial settings unused

No dial settings are required for the Ethernet path. Leave the Dial settings tab unconfigured.

CTPlus Dial settings tab with no modem or telephone settings configured

6. Configure IP and encryption

On the IP/Encryption settings tab, configure:

Setting Value
IP options UDP/IP
Send to address The static IP address of the Home Assistant host
Send port A port reserved for this Home Assistant path
Receive port A port reserved for this Home Assistant path
Encryption type Prefer AES CBC, 128 bit or AES CBC, 256 bit; None is supported
Encryption key A key you choose and enter exactly the same way in TecomHA

Port note: The ports for this path must not conflict with the separate communication path used by CTPlus. Send and receive ports may use the same number when both endpoints are configured that way. If you use different numbers, match each direction in the TecomHA configuration.

The IP address and port numbers in the screenshot are examples only. Do not copy them unless they match your network design.

CTPlus IP and encryption settings for the HomeAssistant communication path

7. Configure advanced settings

On the Advanced settings tab, use the following values:

Setting Value
Message ack 5000 ms
Connect timeout 30 sec
Heartbeat timeout 0 sec
Wait time between connections 5 sec
Computer attempts 255
Connect retries 0
Message retries 3

CTPlus Advanced settings tab configured for TecomHA

8. Choose an authentication method

The Authentication tab lets you use a path user name and password instead of the classic computer/security password.

Method Where to configure it
Security / computer password Enter the path's Security password on the Main tab and leave the Authentication tab empty
Path user name and password Enter both values on the Authentication tab; the security/computer password is then not used

Whichever method you choose must match the Authentication type and credentials configured in TecomHA.

CTPlus Authentication tab for path user name and password authentication

9. Save and send the configuration

Save the communication path, ensure it is enabled, and send the updated configuration to the panel. Then configure TecomHA with the matching panel address, ports, authentication method and encryption settings.

For field-by-field TecomHA guidance, see Configuration. For network and compatibility details, see Panel setup.

10. Import CTPlus names into TecomHA

TecomHA can apply CTPlus object names to entities that are already loaded in Home Assistant.

  1. In CTPlus, open Administration and select Export panel.
  2. Save the resulting export.panel file.
  3. Copy it to a location under Home Assistant's /config directory that TecomHA can read, for example /config/export.panel.
  4. Open Settings → Devices & services → TecomHA → Configure.
  5. Under Naming from export.panel, enter the full path and enable the object groups you want to rename.
  6. Save the integration options.

CTPlus Administration tab with Export panel highlighted

TecomHA Naming from export.panel options in Home Assistant

The import applies friendly names only. It does not create or remove entities. If names change later, replace export.panel and reload the TecomHA integration.

Home Assistant integration menu with Reload highlighted

Next steps