This guide creates a dedicated Computer Event Driven Ethernet communication path for TecomHA. The screenshots show example values; use the IP address, ports, credentials and encryption key for your own installation.
Important: Back up the panel configuration before making changes. In CTPlus, open Administration and export the panel and system configuration as appropriate for your installation.

Use a spare communication-path record and give it a descriptive name such as HomeAssistant. Home Assistant must not share the path used by the CTPlus desktop application.
On the Main tab, configure:
| Setting | Value |
|---|---|
| Interface location | On Board |
| Format | Computer Event Driven |
| Interface port | Ethernet |
TecomHA supports either the classic Security password method or User name and password authentication. Configure only the method you intend to use, then enter the same credentials in Home Assistant.

On the Connection control tab, enable:
- Always connect
- Stay connected on empty buffer
- Control command
- Isolated inputs trigger path

On the Filter tab, enable the event categories TecomHA needs:
- Report alarm events
- Report connection events
- Report system alarms
- Report communication events
- Report access events
- Multi-break alarms
- Multi-break restores
- Report open/close
An event category excluded here will not be delivered to Home Assistant.

On the Test calls tab, set Test call type to No test call.

No dial settings are required for the Ethernet path. Leave the Dial settings tab unconfigured.

On the IP/Encryption settings tab, configure:
| Setting | Value |
|---|---|
| IP options | UDP/IP |
| Send to address | The static IP address of the Home Assistant host |
| Send port | A port reserved for this Home Assistant path |
| Receive port | A port reserved for this Home Assistant path |
| Encryption type | Prefer AES CBC, 128 bit or AES CBC, 256 bit; None is supported |
| Encryption key | A key you choose and enter exactly the same way in TecomHA |
Port note: The ports for this path must not conflict with the separate communication path used by CTPlus. Send and receive ports may use the same number when both endpoints are configured that way. If you use different numbers, match each direction in the TecomHA configuration.
The IP address and port numbers in the screenshot are examples only. Do not copy them unless they match your network design.

On the Advanced settings tab, use the following values:
| Setting | Value |
|---|---|
| Message ack | 5000 ms |
| Connect timeout | 30 sec |
| Heartbeat timeout | 0 sec |
| Wait time between connections | 5 sec |
| Computer attempts | 255 |
| Connect retries | 0 |
| Message retries | 3 |

The Authentication tab lets you use a path user name and password instead of the classic computer/security password.
| Method | Where to configure it |
|---|---|
| Security / computer password | Enter the path's Security password on the Main tab and leave the Authentication tab empty |
| Path user name and password | Enter both values on the Authentication tab; the security/computer password is then not used |
Whichever method you choose must match the Authentication type and credentials configured in TecomHA.

Save the communication path, ensure it is enabled, and send the updated configuration to the panel. Then configure TecomHA with the matching panel address, ports, authentication method and encryption settings.
For field-by-field TecomHA guidance, see Configuration. For network and compatibility details, see Panel setup.
TecomHA can apply CTPlus object names to entities that are already loaded in Home Assistant.
- In CTPlus, open Administration and select Export panel.
- Save the resulting
export.panelfile. - Copy it to a location under Home Assistant's
/configdirectory that TecomHA can read, for example/config/export.panel. - Open Settings → Devices & services → TecomHA → Configure.
- Under Naming from export.panel, enter the full path and enable the object groups you want to rename.
- Save the integration options.


The import applies friendly names only. It does not create or remove entities. If names change later, replace export.panel and reload the TecomHA integration.